Improvements in the accuracy and the repeatability of long trace profiler measurements.

Modifications of the long trace profiler at the Advanced Photon Source at Argonne National Laboratory have significantly improved its accuracy and repeatability for measuring the figure of large flat and long-radius mirrors. Use of a Dove prism in the reference beam path corrects phasing problems between mechanical errors and thermally induced system errors. A single reference correction now completely removes both of these error signals from the measured surface profile. The addition of a precision air conditioner keeps the temperature in the metrology enclosure constant to within +/-0.1 degrees C over a 24-h period and has significantly improved the stability and the repeatability of the measurements. Long-radius surface curvatures can now be measured absolutely with a high degree of confidence. These improved capabilities are illustrated with a series of measurements of a 500-mm-long mirror with a 5-km radius of curvature. The standard deviation in the average of ten slope profile scans is 0.3 microrad, and the corresponding standard deviation in the height error is 4.6 nm.

[1]  I Powell,et al.  Absolute figure measurements with a liquid-flat reference. , 1998, Applied optics.

[2]  K. von Bieren Interferometry of wave fronts reflected off conical surfaces. , 1983 .

[3]  W. Primak Optical flatness standard , 1984 .

[4]  G D Dew,et al.  The measurement of optical flatness. , 1966, Journal of scientific instruments.

[5]  W. Primak The determination of the absolute contours of optical flats. , 1967, Applied optics.

[6]  J Schwider,et al.  Precise measurement of planeness. , 1967, Applied optics.

[7]  H. Barrell,et al.  Liquid Surface Interferometry , 1948, Nature.

[8]  J Grzanna,et al.  Absolute flatness testing by the rotation method with optimal measuring-error compensation. , 1992, Applied optics.

[9]  Parameswaran Hariharan Interferometric testing of optical surfaces: absolute measurements of flatness , 1997 .

[10]  W. B. Emerson Determination of planeness and bending of optical flats , 1952 .

[11]  S. C. Irick,et al.  Determining surface profile from sequential interference patterns from a long trace profiler , 1991 .

[12]  William Primak,et al.  Optical Flatness Standard: Comment , 1989 .

[13]  S. Irick Improved measurement accuracy in a long trace profiler: Compensation for laser pointing instability , 1993 .

[14]  W. McKinney,et al.  Using a straightness reference in obtaining more accurate surface profiles from a long trace profiler , 1992 .

[15]  Shinan Qian,et al.  The penta‐prism LTP: A long‐trace‐profiler with stationary optical head and moving penta prism (abstract)a) , 1995 .

[16]  A. Vivo,et al.  Optical metrology facility at the ESRF , 1995 .