Wavelet scattering transform and long short-term memory network-based noninvasive blood pressure estimation from photoplethysmograph signals

Measuring blood pressure from photoplethysmograph (PPG) signals is gaining popularity as the PPG devices are inexpensive, convenient to use and much portable. The advent of wearable PPG devices, machine learning and signal processing has motivated in the development of cuffless blood pressure calculation from PPG signals captured from fingertip. The conventional pulse transit time-based method of measuring blood pressure from PPG is inconvenient as it requires electrocardiogram signals and PPG signals or PPG signals captured simultaneously from two different sites of the body. The proposed system uses the PPG signals alone to estimate blood pressure (BP). A signal analysis method called wavelet scattering transform is applied on the preprocessed PPG signals to extract features. Predictor model that estimates BP are derived by training the support vector regression model and long short term memory prediction model. The derived models are evaluated with testing dataset and the results are compared with ground truth values. The results show that the accuracy of the proposed method achieves grade B for the estimation of the diastolic blood pressure and grade C for the mean arterial pressure under the standard British Hypertension Society protocol. On comparing the results of the proposed system with the benchmark machine learning algorithms, it is observed that the proposed model outperforms others by a considerable margin. A comparative analysis with prior studies shows that the results obtained from proposed work are comparable with existing works in the literature.

[1]  Chaewoo Lee,et al.  A Wavelet Scattering Feature Extraction Approach for Deep Neural Network Based Indoor Fingerprinting Localization , 2019, Sensors.

[2]  Maram Maheedhar,et al.  Cuff-less PPG based continuous blood pressure monitoring - A smartphone based approach , 2016, EMBC.

[3]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[4]  Roger G. Mark,et al.  An open-source algorithm to detect onset of arterial blood pressure pulses , 2003, Computers in Cardiology, 2003.

[5]  Jürgen Schmidhuber,et al.  Long Short-Term Memory , 1997, Neural Computation.

[6]  M. Y. Mashor,et al.  Measuring Blood Pressure Using a Photoplethysmography Approach , 2008 .

[7]  Michael Böhm,et al.  Relationship between pulse transit time and blood pressure is impaired in patients with chronic heart failure , 2010, Clinical Research in Cardiology.

[8]  Nigel H. Lovell,et al.  The use of photoplethysmography for assessing hypertension , 2019, npj Digital Medicine.

[9]  Bernhard Schölkopf,et al.  A tutorial on support vector regression , 2004, Stat. Comput..

[10]  Ram Dantu,et al.  Cuffless Differential Blood Pressure Estimation Using Smart Phones , 2013, IEEE Transactions on Biomedical Engineering.

[11]  Alpha Agape Gopalai,et al.  Blood Pressure measurement from Photo-Plethysmography to Pulse Transit Time , 2014, 2014 IEEE Conference on Biomedical Engineering and Sciences (IECBES).

[12]  Wen Jun Jiang,et al.  Data-driven estimation of blood pressure using photoplethysmographic signals , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[13]  Mirza Mansoor Baig,et al.  Smartphone-based continuous blood pressure monitoring application - robust security and privacy framework , 2016, 2016 IEEE Region 10 Conference (TENCON).

[14]  Mahdi Shabany,et al.  Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring , 2017, IEEE Transactions on Biomedical Engineering.

[15]  Yugang Niu,et al.  Hourly day-ahead solar irradiance prediction using weather forecasts by LSTM , 2018 .

[16]  Cinna Soltanpur,et al.  A review on wearable photoplethysmography sensors and their potential future applications in health care , 2018, International journal of biosensors & bioelectronics.

[17]  Y.T. Zhang,et al.  Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[18]  Wang Yi,et al.  Noninvasive and Continuous Blood Pressure Monitoring Using Wearable Body Sensor Networks , 2015, IEEE Intelligent Systems.

[19]  Yong Lian,et al.  PTT based continuous time non-invasive blood pressure system , 2016, 2016 IEEE 59th International Midwest Symposium on Circuits and Systems (MWSCAS).

[20]  Hoda Mohammadzade,et al.  Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time , 2015, 2015 IEEE International Symposium on Circuits and Systems (ISCAS).

[21]  Domenico Grimaldi,et al.  A Neural Network-based method for continuous blood pressure estimation from a PPG signal , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[22]  Lai-Man Po,et al.  Cuffless Blood Pressure Estimation Based on Photoplethysmography Signal and Its Second Derivative , 2017 .

[23]  Y.T. Zhang,et al.  Noninvasive Estimation of Blood Pressure Using Photoplethysmographic Signals in the Period Domain , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[24]  Mingshan Sun,et al.  Optical blood pressure estimation with photoplethysmography and FFT-based neural networks. , 2016, Biomedical optics express.

[25]  David Fofi,et al.  Heart rate estimation using facial video: A review , 2017, Biomed. Signal Process. Control..

[26]  Stéphane Mallat,et al.  Invariant Scattering Convolution Networks , 2012, IEEE transactions on pattern analysis and machine intelligence.

[27]  Shubhajit Roy Chowdhury,et al.  Noninvasive cuff'less estimation of blood pressure using Photoplethysmography without electrocardiograph measurement , 2014, 2014 IEEE REGION 10 SYMPOSIUM.

[28]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[29]  G Parati,et al.  Blood pressure measuring devices: recommendations of the European Society of Hypertension , 2001, BMJ : British Medical Journal.

[30]  C. Lim,et al.  Evaluation of blood pressure changes using vascular transit time , 2006, Physiological measurement.

[31]  Matjaz Gams,et al.  Non-Invasive Blood Pressure Estimation from ECG Using Machine Learning Techniques , 2018, Sensors.