A High-performance Homogeneous Droplet Routing Technique for MEDA-based Biochips

Recent advancement of microelectrode-dot-array (MEDA)-based architecture for digital microfluidic biochips has enabled a major enhancement in microfluidic operations for traditional lab-on-chip devices. One critical issue for MEDA-based biochips is the transportation of droplets. MEDA allows dynamic routing for droplets of different size. In this article, we propose a high-performance droplet routing technique for MEDA-based digital microfluidic biochips. First, we propose the basic concept of droplet movement strategy in MEDA-based design together with a definition of strictly shielded zones within the layout in MEDA architecture. Next, we propose transportation schemes of droplets for MEDA architecture under different blockage or crossover conditions and estimate route distances for each net in offline. Finally, a priority-based routing strategy combining various transportation schemes stated earlier has been proposed. Concurrent movement of each droplet is scheduled in a time-multiplexed manner. This poses critical challenges for parallel routing of individual droplets with optimal sharing of cells formulating a routing problem with higher complexity. The final compaction solution satisfies the timing constraint and improves fault tolerance. Simulations are carried out on standard benchmark circuits, namely, Benchmark suite I and Benchmark suite III. Experimental results show satisfactory improvements and prove a high degree of robustness for our proposed algorithm.

[1]  Ansuman Banerjee,et al.  Flexible Droplet Routing in Active Matrix–Based Digital Microfluidic Biochips , 2018, ACM Trans. Design Autom. Electr. Syst..

[2]  Jun Zeng,et al.  Principles of droplet electrohydrodynamics for lab-on-a-chip. , 2004, Lab on a chip.

[3]  Philip Brisk,et al.  Fast online synthesis of generally programmable digital microfluidic biochips , 2012, CODES+ISSS.

[4]  Fei Su,et al.  Droplet Routing in the Synthesis of Digital Microfluidic Biochips , 2006, Proceedings of the Design Automation & Test in Europe Conference.

[5]  Yici Cai,et al.  Practical functional and washing droplet routing for cross-contamination avoidance in digital microfluidic biochips , 2014, 2014 51st ACM/EDAC/IEEE Design Automation Conference (DAC).

[6]  S. Fan,et al.  Digital microfluidic operations on micro-electrode array architecture , 2011, NEMS 2011.

[7]  Krishnendu Chakrabarty,et al.  Synchronization of washing operations with droplet routing for cross-contamination avoidance in digital microfluidic biochips , 2010, Design Automation Conference.

[8]  Krishnendu Chakrabarty,et al.  Cross-contamination avoidance for droplet routing in digital microfluidic biochips , 2009, 2009 Design, Automation & Test in Europe Conference & Exhibition.

[9]  Hung-Ming Chen,et al.  Multi-level droplet routing in active-matrix based digital-microfluidic biochips , 2018, 2018 23rd Asia and South Pacific Design Automation Conference (ASP-DAC).

[10]  Richard B. Fair,et al.  Protein stamping for MALDI mass spectrometry using an electrowetting-based microfluidic platform , 2004, SPIE Optics East.

[11]  Robert Wille,et al.  Exact routing for digital microfluidic biochips with temporary blockages , 2014, 2014 IEEE/ACM International Conference on Computer-Aided Design (ICCAD).

[12]  Tsung-Wei Huang,et al.  A fast routability- and performance-driven droplet routing algorithm for digital microfluidic biochips , 2009, 2009 IEEE International Conference on Computer Design.

[13]  Krishnendu Chakrabarty,et al.  Synthesis of Error-Recovery Protocols for Micro-Electrode-Dot-Array Digital Microfluidic Biochips , 2017, ACM Trans. Embed. Comput. Syst..

[14]  Robert Wille,et al.  Exact routing for micro-electrode-dot-array digital microfluidic biochips , 2017, 2017 22nd Asia and South Pacific Design Automation Conference (ASP-DAC).

[15]  R. Fair,et al.  An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. , 2004, Lab on a chip.

[16]  Yao-Wen Chang,et al.  BioRoute: a network-flow based routing algorithm for digital microfluidic biochips , 2007, 2007 IEEE/ACM International Conference on Computer-Aided Design.

[17]  Yingchieh Ho,et al.  Design of a micro-electrode cell for programmable lab-on-CMOS platform , 2016, 2016 IEEE International Symposium on Circuits and Systems (ISCAS).

[18]  Yao-Wen Chang,et al.  A progressive-ILP based routing algorithm for cross-referencing biochips , 2008, 2008 45th ACM/IEEE Design Automation Conference.

[19]  Zhongkai Chen,et al.  Droplet routing in high-level synthesis of configurable digital microfluidic biochips based on microelectrode dot array architecture , 2011 .

[20]  Tsung-Yi Ho,et al.  Module Placement under Completion-Time Uncertainty in Micro-Electrode-Dot-Array Digital Microfluidic Biochips , 2018, IEEE Transactions on Multi-Scale Computing Systems.

[21]  Fei Su,et al.  Defect-Aware High-Level Synthesis and Module Placement for Microfluidic Biochips , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[22]  Carlos A. Brizuela,et al.  A genetic algorithm for the routing of droplets in DMFB: Preliminary results , 2014, 2014 IEEE International Conference on Systems, Man, and Cybernetics (SMC).

[23]  Yi-Wen Lu,et al.  Field-programmable lab-on-a-chip based on microelectrode dot array architecture. , 2014, IET nanobiotechnology.

[24]  Pranab Roy,et al.  Homogeneous droplet routing in DMFB: An enhanced technique for high performance bioassay implementation , 2018, Integr..

[25]  Frank O. Hadlock,et al.  A shortest path algorithm for grid graphs , 1977, Networks.

[26]  Tsung-Wei Huang,et al.  A Contamination Aware Droplet Routing Algorithm for the Synthesis of Digital Microfluidic Biochips , 2010, IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems.

[27]  A. Wheeler,et al.  Digital microfluidics for cell-based assays. , 2008, Lab on a chip.

[28]  V. Bahadur,et al.  An energy-based model for electrowetting-induced droplet actuation , 2006 .

[29]  Chen-Yi Lee,et al.  An Intelligent Digital Microfluidic Processor for Biomedical Detection , 2015, J. Signal Process. Syst..

[30]  David Z. Pan,et al.  A High-Performance Droplet Routing Algorithm for Digital Microfluidic Biochips , 2008, IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems.

[31]  Gary Wang,et al.  FIELD-PROGRAMMABLE MICROFLUIDIC TEST PLATFORM FOR POINT-OF-CARE DIAGNOSTICS , 2013 .

[32]  Krishnendu Chakrabarty,et al.  Broadcast electrode-addressing for pin-constrained multi-functional digital microfluidic biochips , 2008, 2008 45th ACM/IEEE Design Automation Conference.

[33]  Robert Wille,et al.  A general and exact routing methodology for Digital Microfluidic Biochips , 2015, 2015 IEEE/ACM International Conference on Computer-Aided Design (ICCAD).

[34]  Krishnendu Chakrabarty,et al.  Droplet Size-Aware High-Level Synthesis for Micro-Electrode-Dot-Array Digital Microfluidic Biochips , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[35]  Mohamed Ibrahim,et al.  Digital-Microfluidic Biochips , 2006, Computer.

[36]  Mark K. Goldberg,et al.  Performance Characterization of a Reconfigurable Planar-Array Digital Microfluidic System , 2006, IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems.

[37]  Yao-Wen Chang,et al.  Cross-contamination aware design methodology for pin-constrained digital microfluidic biochips , 2010, Design Automation Conference.