Effect of radiologists’ experience on breast cancer detection and localization using digital breast tomosynthesis

AbstractObjectivesThe objectives are To to compare the diagnostic performance of combined digital breast tomosynthesis (DBT) and digital mammography (DM) with that of DM alone, as a function of radiologists’ experience with DBT.MethodsEthical committee approval was obtained. Fifty cases (27 cancer, 23 normal), each containing both digital mammography (DM) and digital breast tomosynthesis (DBT) images, were reviewed by 26 radiologists, divided into three groups according to level of experience with DBT (none, workshop experience, and clinical experience). The radiologists’ diagnostic performance using DM was compared with that using DM + DBT, and evaluated by area under receiver-operating characteristic curve (AUC), jackknife free-response receiver-operator characteristics figure of metric (JAFROC FOM), sensitivity, location sensitivity, and specificity.ResultsFor all readers combined, performance using DM + DBT was significantly higher than for DM alone by both AUC (0.788 vs 0.681, p < 0.001) and JAFROC FOM (0.745 vs 0.621, p < 0.001). Similar results were obtained for readers with no DBT experience (AUC 0.775 vs 0.682, p = 0.004; JAFROC FOM 0.695 vs 0.603, p = 0.016) and with clinical DBT experience (AUC 0.789 vs 0.681, p = 0.042; and JAFROC FOM 0.764 vs 0.632, p = 0.031).ConclusionsAddition of DBT to DM significantly improves radiologists’ diagnostic performance whether or not they have prior DBT experience.Key p oints• Adding DBT to DM increased the number of detected cancers • DBT + DM led to more accurate localization of breast cancers than DM • Addition of DBT improved radiologists’ performance regardless of prior DBT experience • High-volume radiologists with different DBT experience levels performed similarly on DM + DBT

[1]  J. Ferlay,et al.  Global Cancer Statistics, 2002 , 2005, CA: a cancer journal for clinicians.

[2]  David Gur,et al.  Tomosynthesis-based imaging of the breast. , 2011, Academic radiology.

[3]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[4]  Christer Ullberg,et al.  Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography , 2011, Acta radiologica.

[5]  Anders Tingberg,et al.  Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography , 2010, Acta radiologica.

[6]  David Gur,et al.  Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. , 2011, AJR. American journal of roentgenology.

[7]  Andriy I. Bandos,et al.  Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. , 2013, Radiology.

[8]  Per Skaane,et al.  Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study. , 2003, Radiology.

[9]  S. Rose,et al.  Implementation of breast tomosynthesis in a routine screening practice: an observational study. , 2013, AJR. American journal of roentgenology.

[10]  Andrew P. Smith,et al.  Clinical Performance of Breast Tomosynthesis as a Function of Radiologist Experience Level , 2008, Digital Mammography / IWDM.

[11]  S. Ciatto,et al.  Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. , 2013, The Lancet. Oncology.

[12]  C. D'Orsi,et al.  Diagnostic Performance of Digital Versus Film Mammography for Breast-Cancer Screening , 2005, The New England journal of medicine.

[13]  Kenneth G. A. Gilhuijs,et al.  Breast tomosynthesis in clinical practice: initial results , 2009, European Radiology.

[14]  Fred S Vernacchia,et al.  Digital mammography: its impact on recall rates and cancer detection rates in a small community-based radiology practice. , 2009, AJR. American journal of roentgenology.

[15]  E. Halpern,et al.  Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial. , 2013, Radiology.

[16]  T M Svahn,et al.  Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy. , 2012, The British journal of radiology.

[17]  Gisella Gennaro,et al.  Clinical Performance of Digital Breast Tomosynthesis Versus Full-Field Digital Mammography: Preliminary Results , 2008, Digital Mammography / IWDM.

[18]  J M Dixon,et al.  Screening for breast cancer , 1993, The British journal of surgery.

[19]  A. Jemal,et al.  Global Cancer Statistics , 2011 .

[20]  C. Waldherr,et al.  Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening. , 2013, AJR. American journal of roentgenology.

[21]  Federica Zanca,et al.  Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study. , 2012, Radiology.

[22]  Gisella Gennaro,et al.  Digital breast tomosynthesis versus digital mammography: a clinical performance study , 2010, European Radiology.

[23]  D. Parkin,et al.  Global cancer statistics in the year 2000. , 2001, The Lancet. Oncology.

[24]  David Gur,et al.  Digital breast tomosynthesis: observer performance study. , 2009, AJR. American journal of roentgenology.

[25]  I Andersson,et al.  The diagnostic accuracy of dual-view digital mammography, single-view breast tomosynthesis and a dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study. , 2010, Radiation protection dosimetry.

[26]  F J Gilbert,et al.  The Royal College of Radiologists Breast Group breast imaging classification. , 2009, Clinical radiology.

[27]  L. Tabár,et al.  The impact of organized mammography service screening on breast carcinoma mortality in seven Swedish counties , 2002, Cancer.

[28]  KathleenR. Brandt,et al.  Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting. , 2013, AJR. American journal of roentgenology.

[29]  R. L. Birdwell Digital Breast Tomosynthesis: A Pilot Observer Study , 2009 .