A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.

A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region of interest within the image in circular cone-beam and fan-beam cases. Recently, we have developed a 3D FBP-based algorithm for image reconstruction on PI-line segments in a helical cone-beam scan. In this work, we demonstrated that the 3D FBP-based algorithm indeed provided a rather general formulation for image reconstruction from divergent projections (such as cone-beam and fan-beam projections). On the basis of this formulation we derived new approximate or exact algorithms for image reconstruction in circular cone-beam or fan-beam scans, which can be interpreted as special cases of the helical scan. Existing algorithms corresponding to the derived algorithms were identified. We also performed a preliminary numerical study to verify our theoretical results in each of the cases. The results in the work can readily be generalized to other non-circular trajectories.

[1]  Xiaochuan Pan,et al.  Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT. , 2004, Physics in medicine and biology.

[2]  Hiroyuki Kudo,et al.  New super-short-scan algorithms for fan-beam and cone-beam reconstruction , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[3]  Y. Liu,et al.  Half-scan cone-beam x-ray microtomography formula. , 2008, Scanning.

[4]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[5]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[6]  Xiaochuan Pan,et al.  Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography. , 2003, Medical physics.

[7]  M. Defrise,et al.  A solution to the long-object problem in helical cone-beam tomography. , 2000, Physics in medicine and biology.

[8]  R Y Levine,et al.  Optimum beam configurations in tomographic intensity modulated radiation therapy. , 2000, Physics in medicine and biology.

[9]  Xiaochuan Pan,et al.  Optimal noise control in and fast reconstruction of fan-beam computed tomography image. , 1999, Medical physics.

[10]  Kwok C. Tam Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: theory , 2000, Medical Imaging: Image Processing.

[11]  Henrik Turbell,et al.  Cone-Beam Reconstruction Using Filtered Backprojection , 2001 .

[12]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[13]  Guy M. Besson,et al.  CT image reconstruction from fan‐parallel data , 1999 .

[14]  Hui Hu,et al.  AN IMPROVED CONE-BEAM RECONSTRUCTION ALGORITHM FOR THE CIRCULAR ORBIT , 2006 .

[15]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[16]  M. Grass,et al.  3D cone-beam CT reconstruction for circular trajectories. , 2000, Physics in medicine and biology.

[17]  Hiroyuki Kudo,et al.  Image reconstruction from fan-beam projections on less than a short scan , 2002, Physics in medicine and biology.

[18]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.