Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System

Breathing frequency (fB) is an important vital sign that—if appropriately monitored—may help to predict clinical adverse events. Inertial sensors open the door to the development of low-cost, wearable, and easy-to-use breathing-monitoring systems. The present paper proposes a new posture-independent processing algorithm for breath-by-breath extraction of breathing temporal parameters from chest-wall inclination change signals measured using inertial measurement units. An important step of the processing algorithm is dimension reduction (DR) that allows the extraction of a single respiratory signal starting from 4-component quaternion data. Three different DR methods are proposed and compared in terms of accuracy of breathing temporal parameter estimation, in a group of healthy subjects, considering different breathing patterns and different postures; optoelectronic plethysmography was used as reference system. In this study, we found that the method based on PCA-fusion of the four quaternion components provided the best fB estimation performance in terms of mean absolute errors (<2 breaths/min), correlation (r > 0.963) and Bland–Altman Analysis, outperforming the other two methods, based on the selection of a single quaternion component, identified on the basis of spectral analysis; particularly, in supine position, results provided by PCA-based method were even better than those obtained with the ideal quaternion component, determined a posteriori as the one providing the minimum estimation error. The proposed algorithm and system were able to successfully reconstruct the respiration-induced movement, and to accurately determine the respiratory rate in an automatic, position-independent manner.

[1]  Sebastian Madgwick,et al.  Estimation of IMU and MARG orientation using a gradient descent algorithm , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[2]  A. Pedotti,et al.  Effects of gender and posture on thoraco-abdominal kinematics during quiet breathing in healthy adults , 2010, Respiratory Physiology & Neurobiology.

[3]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[4]  J. Mead,et al.  Measurement of the separate volume changes of rib cage and abdomen during breathing. , 1967, Journal of applied physiology.

[5]  Andrea Aliverti,et al.  Effects of a multidisciplinary body weight reduction program on static and dynamic thoraco-abdominal volumes in obese adolescents. , 2016, Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.

[6]  C. Subbe,et al.  Effect of introducing the Modified Early Warning score on clinical outcomes, cardio‐pulmonary arrests and intensive care utilisation in acute medical admissions * , 2003, Anaesthesia.

[7]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[8]  Guy A. Dumont,et al.  Correction: Improving the Accuracy and Efficiency of Respiratory Rate Measurements in Children Using Mobile Devices , 2015, PloS one.

[9]  H. Hotelling Analysis of a complex of statistical variables into principal components. , 1933 .

[10]  Won-Ki Kim,et al.  Improvement of Dynamic Respiration Monitoring Through Sensor Fusion of Accelerometer and Gyro-sensor , 2014 .

[11]  Y. Benjamini,et al.  Controlling the false discovery rate: a practical and powerful approach to multiple testing , 1995 .

[12]  A. Pedotti,et al.  Compartmental Analysis of Breathing in the Supine and Prone Positions by Optoelectronic Plethysmography , 2004, Annals of Biomedical Engineering.

[13]  J.A. Fiz,et al.  Assessment of respiratory muscle effort studying diaphragm movement registered with surface sensors. Animal model (dogs) , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  John Ludbrook,et al.  Confidence in Altman–Bland plots: A critical review of the method of differences , 2010, Clinical and experimental pharmacology & physiology.

[15]  E. Alasaarela,et al.  Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor , 2006, Proceedings of the 2006 IEEE Sensors Applications Symposium, 2006..

[16]  U. Koehler,et al.  [Respiratory Rate - a Neglected Vital Sign]. , 2017, Deutsche medizinische Wochenschrift.

[17]  William Rowan Hamilton,et al.  XI. On quaternions; or on a new system of imaginaries in algebra , 1848 .

[18]  Katarzyna Radecka,et al.  A Medical Cloud-Based Platform for Respiration Rate Measurement and Hierarchical Classification of Breath Disorders , 2014, Sensors.

[19]  D. K. Arvind,et al.  Simultaneous Activity and Respiratory Monitoring Using an Accelerometer , 2011, 2011 International Conference on Body Sensor Networks.

[20]  Andrea Aliverti,et al.  Acute Effects of Mechanical Insufflation-Exsufflation on the Breathing Pattern in Stable Subjects With Duchenne Muscular Dystrophy , 2018, Respiratory Care.

[21]  H. Gollee,et al.  Real-time detection of respiratory activity using an inertial measurement unit , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  A Pedotti,et al.  Rib cage mechanics during quiet breathing and exercise in humans. , 1997, Journal of applied physiology.

[23]  Daniel Sánchez Morillo,et al.  An Accelerometer-Based Device for Sleep Apnea Screening , 2010, IEEE Transactions on Information Technology in Biomedicine.

[24]  Benjamin Pfaff A History Of Non Euclidean Geometry Evolution Of The Concept Of A Geometric Space , 2016 .

[25]  Y. Benjamini,et al.  THE CONTROL OF THE FALSE DISCOVERY RATE IN MULTIPLE TESTING UNDER DEPENDENCY , 2001 .

[26]  Karl Pearson F.R.S. LIII. On lines and planes of closest fit to systems of points in space , 1901 .

[27]  Annet J. Dallmeijer,et al.  The importance of addressing heteroscedasticity in the reliability analysis of ratio‐scaled variables: an example based on walking energy‐cost measurements , 2012, Developmental Medicine & Child Neurology.

[28]  Andrea Aliverti,et al.  A novel, low cost, wearable contact-based device for breathing frequency monitoring , 2017, 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[29]  William Rowan Hamilton,et al.  ON QUATERNIONS, OR ON A NEW SYSTEM OF IMAGINARIES IN ALGEBRA , 1847 .

[30]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[31]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[32]  S. J. Cala,et al.  Chest wall and lung volume estimation by optical reflectance motion analysis. , 1996, Journal of applied physiology.

[33]  D. K. Arvind,et al.  Respiratory Rate and Flow Waveform Estimation from Tri-axial Accelerometer Data , 2010, 2010 International Conference on Body Sensor Networks.

[34]  Carol Ewing Garber,et al.  Optoelectronic plethysmography compared to spirometry during maximal exercise , 2013, Respiratory Physiology & Neurobiology.

[35]  G Ferrigno,et al.  Three-dimensional optical analysis of chest wall motion. , 1994, Journal of applied physiology.

[36]  Stéphane Bonnet,et al.  Estimation of respiratory waveform using an accelerometer , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[37]  L. Masotti,et al.  Respiratory rate assessments using a dual-accelerometer device , 2014, Respiratory Physiology & Neurobiology.

[38]  A Pedotti,et al.  Abdominal volume contribution to tidal volume as an early indicator of respiratory impairment in Duchenne muscular dystrophy , 2009, European Respiratory Journal.

[39]  Yan-Wei Guo,et al.  Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. , 2011, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[40]  Kee S. Moon,et al.  Extraction and Analysis of Respiratory Motion Using Wearable Inertial Sensor System during Trunk Motion , 2017, Sensors.

[41]  Bozena Kaminska,et al.  Validation of respiratory signal derived from suprasternal notch acceleration for sleep apnea detection , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[42]  Ronald M. Aarts,et al.  Performance evaluation of a tri-axial accelerometry-based respiration monitoring for ambient assisted living , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[43]  A Pedotti,et al.  Optoelectronic plethysmography in intensive care patients. , 2000, American journal of respiratory and critical care medicine.

[44]  A Pedotti,et al.  Opto-electronic plethysmography. , 2003, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.