Risk factors for distal stent graft-induced new entry following endovascular repair of type B aortic dissection.

BACKGROUND Distal stent graft-induced new entry (DSINE) has been increasingly observed following thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD). We seek to identify the risk factors for DSINE following TEVAR in patients with TBAD. METHODS Between January 2009 and January 2013, we performed TEVAR for 579 patients with TBAD. The clinical data were retrospectively analyzed with univariate and multivariate analyses to identify the risk factors for DSINE. RESULTS Two patients (0.3%) died after the initial TEVAR. Morbidity included spinal cord injury in 2 (0.3%), stroke in 3 (0.5%) and endoleak in 12 (2.1%) patients. Clinical and radiological follow-up was complete in 100% (577/577) averaging 47±16 months. Late death occurred in 6 patients. DSINE occurred in 39 patients (6.7%) at mean 22±17 months after the initial TEVAR, which was managed with re-TEVAR in 25 and medically in 14. At 33±18 months after DSINE, 11 of patients managed medically (11/14) and all patients managed with re-TEVAR (25/25) survived (P=0.048). Freedom from DSINE was 92.7% at 5 years (95% CI: 90.0-94.7%). Using tapered stent grafts with a proximal end 4-8 mm larger than the distal end, TEVAR performed in the acute phase (≤14 days from onset) was associated with a significantly lower incidence of DSINE than TEVAR performed in the chronic phase (4.3%, 7/185 vs. 13.9%, 15/108; P=0.003). Risk factors for DSINE were stent grafts less than 145 mm in length [odds ratio (OR) 2.268; 95% CI: 1.121-4.587; P=0.023] and TEVAR performed in the chronic phase (OR 1.935; 95% CI: 1.004-3.731; P=0.049). CONCLUSIONS Our results show that TEVAR performed during the acute phase and using stent grafts longer than 145 mm could decrease the incidence of DSINE in patients with TBAD. Tapered stent grafts with a proximal end 4-8 mm larger than the distal end may be helpful in preventing DSINE after TEVAR performed in the acute phase than TEVAR performed in the chronic phase, due to the difference in mobility of the dissected flap. Expedite repeat TEVAR is recommended to improve the clinical prognosis for patients with DSINE.

[1]  A. Dardik,et al.  Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection. , 2015, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[2]  G. Hughes,et al.  Thoracic endovascular aortic repair for chronic DeBakey IIIb aortic dissection. , 2014, The Annals of thoracic surgery.

[3]  G. Hughes,et al.  Current management and outcome of chronic type B aortic dissection: results with open and endovascular repair since the advent of thoracic endografting. , 2014, Annals of cardiothoracic surgery.

[4]  I. Chen,et al.  Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection. , 2013, The Journal of thoracic and cardiovascular surgery.

[5]  T. Yamakawa,et al.  Application of Protective Stents in Endovascular Repair of Acute Complicated Stanford Type B Aortic Dissections , 2013, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[6]  Z. Jing,et al.  Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection. , 2013, Journal of vascular surgery.

[7]  I. Chen,et al.  Reintervention for distal stent graft-induced new entry after endovascular repair with a stainless steel-based device in aortic dissection. , 2013, Journal of vascular surgery.

[8]  I. Chen,et al.  Aortic remodeling after endovascular repair with stainless steel-based stent graft in acute and chronic type B aortic dissection. , 2012, Journal of vascular surgery.

[9]  Chunsheng Wang,et al.  Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection. , 2010, Journal of vascular surgery.

[10]  Shang-dong Xu,et al.  Early and midterm results of thoracic endovascular aortic repair of chronic type B aortic dissection. , 2010, The Journal of thoracic and cardiovascular surgery.

[11]  J. Ricotta Invited commentary. Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection. , 2010, Journal of vascular surgery.

[12]  Yuan Ji,et al.  Retrograde Type A Aortic Dissection After Endovascular Stent Graft Placement for Treatment of Type B Dissection , 2009, Circulation.

[13]  P. Matute,et al.  Stent Grafting–Related Acute Type B Redissection , 2008, Vascular.

[14]  Shang-dong Xu,et al.  A study of aortic dimension in type B aortic dissection. , 2007, Interactive cardiovascular and thoracic surgery.

[15]  I. Kiyotaka,et al.  Early and medium-term results of stent-graft treatment of DeBakey type III aortic dissection. , 2006, The Journal of cardiovascular surgery.

[16]  Shang-dong Xu,et al.  Endovascular repair of acute type B aortic dissection: early and mid-term results. , 2006, Journal of vascular surgery.

[17]  Sang Joon Park,et al.  Problems encountered during and after stent-graft treatment of aortic dissection. , 2006, Journal of vascular and interventional radiology : JVIR.

[18]  C. Nienaber,et al.  Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. , 1999, The New England journal of medicine.

[19]  T Hirano,et al.  Endovascular stent-graft placement for the treatment of acute aortic dissection. , 1999, The New England journal of medicine.

[20]  R. S. Mitchell,et al.  Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. , 1994, The New England journal of medicine.

[21]  J. Parodi,et al.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms , 1991, Annals of vascular surgery.