A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance.

PURPOSE Patients' interfractional anatomic changes can compromise the initial treatment plan quality. To overcome this issue, adaptive radiotherapy (ART) has been introduced. Deformable image registration (DIR) is an important tool for ART and several deformable phantoms have been built to evaluate the algorithms' accuracy. However, there is a lack of deformable phantoms that can also provide dosimetric information to verify the accuracy of the whole ART process. The goal of this work is to design and construct a deformable head and neck (HN) ART quality assurance (QA) phantom with in vivo dosimetry. METHODS An axial slice of a HN patient is taken as a model for the phantom construction. Six anatomic materials are considered, with HU numbers similar to a real patient. A filled balloon inside the phantom tissue is inserted to simulate tumor. Deflation of the balloon simulates tumor shrinkage. Nonradiopaque surface markers, which do not influence DIR algorithms, provide the deformation ground truth. Fixed and movable holders are built in the phantom to hold a diode for dosimetric measurements. RESULTS The measured deformations at the surface marker positions can be compared with deformations calculated by a DIR algorithm to evaluate its accuracy. In this study, the authors selected a Demons algorithm as a DIR algorithm example for demonstration purposes. The average error magnitude is 2.1 mm. The point dose measurements from the in vivo diode dosimeters show a good agreement with the calculated doses from the treatment planning system with a maximum difference of 3.1% of prescription dose, when the treatment plans are delivered to the phantom with original or deformed geometry. CONCLUSIONS In this study, the authors have presented the functionality of this deformable HN phantom for testing the accuracy of DIR algorithms and verifying the ART dosimetric accuracy. The authors' experiments demonstrate the feasibility of this phantom serving as an end-to-end ART QA phantom.

[1]  D. Yan,et al.  Adaptive radiation therapy , 1997, Physics in medicine and biology.

[2]  J A Antolak,et al.  Prostate target volume variations during a course of radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[3]  Jean-Philippe Thirion,et al.  Image matching as a diffusion process: an analogy with Maxwell's demons , 1998, Medical Image Anal..

[4]  R. Jeraj,et al.  Re-optimization in adaptive radiotherapy. , 2002, Physics in medicine and biology.

[5]  T. Mackie,et al.  Fast free-form deformable registration via calculus of variations , 2004, Physics in medicine and biology.

[6]  Sarang Joshi,et al.  Large deformation three-dimensional image registration in image-guided radiation therapy , 2005, Physics in medicine and biology.

[7]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[8]  He Wang,et al.  Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. , 2005, International journal of radiation oncology, biology, physics.

[9]  Martijn Ketelaars,et al.  Conventional, conformal, and intensity-modulated radiation therapy treatment planning of external beam radiotherapy for cervical cancer: The impact of tumor regression. , 2006, International journal of radiation oncology, biology, physics.

[10]  Weiguo Lu,et al.  Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy , 2006, Physics in medicine and biology.

[11]  Di Yan,et al.  Automatic delineation of on-line head-and-neck computed tomography images: toward on-line adaptive radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[12]  Lei Xing,et al.  Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control framework , 2007, Physics in medicine and biology.

[13]  Rojano Kashani,et al.  Technical note: a physical phantom for assessment of accuracy of deformable alignment algorithms. , 2007, Medical physics.

[14]  Lei Xing,et al.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation , 2007, Physics in medicine and biology.

[15]  Vladimir Pekar,et al.  Assessment of a model-based deformable image registration approach for radiation therapy planning. , 2007, International journal of radiation oncology, biology, physics.

[16]  Benoît Macq,et al.  Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  Mark Holden,et al.  A Review of Geometric Transformations for Nonrigid Body Registration , 2008, IEEE Transactions on Medical Imaging.

[18]  Jan Seuntjens,et al.  A deformable phantom for 4D radiotherapy verification: design and image registration evaluation. , 2008, Medical physics.

[19]  Mingli Chen,et al.  Adaptive fractionation therapy: I. Basic concept and strategy , 2008, Physics in medicine and biology.

[20]  Deshan Yang,et al.  A fast inverse consistent deformable image registration method based on symmetric optical flow computation , 2008, 2008 42nd Asilomar Conference on Signals, Systems and Computers.

[21]  D. Yan,et al.  Developing quality assurance processes for image-guided adaptive radiation therapy. , 2008, International journal of radiation oncology, biology, physics.

[22]  Vira Chankong,et al.  On-line re-optimization of prostate IMRT plans for adaptive radiation therapy , 2008, Physics in medicine and biology.

[23]  Steve B. Jiang,et al.  GPU-based ultrafast IMRT plan optimization , 2009, Physics in medicine and biology.

[24]  Dwight E Heron,et al.  A cone beam CT-guided online plan modification technique to correct interfractional anatomic changes for prostate cancer IMRT treatment , 2009, Physics in medicine and biology.

[25]  Steve B. Jiang,et al.  GPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy , 2010, Physics in medicine and biology.

[26]  Steve B Jiang,et al.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU. , 2010, Physics in medicine and biology.

[27]  Neil Kirby,et al.  A two-dimensional deformable phantom for quantitatively verifying deformation algorithms. , 2011, Medical physics.

[28]  Matthias Guckenberger,et al.  A multi-institution evaluation of deformable image registration algorithms for automatic organ delineation in adaptive head and neck radiotherapy , 2012, Radiation oncology.

[29]  Linghong Zhou,et al.  CT to cone-beam CT deformable registration with simultaneous intensity correction , 2012, Medical physics.

[30]  J. Pouliot,et al.  The need for application-based adaptation of deformable image registration. , 2012, Medical physics.

[31]  P Subramanian,et al.  Image Registration Methods , 2016 .