In vivo dosimetry with MOSFETs and GAFCHROMIC films during electron IORT for Accelerated Partial Breast Irradiation.

PURPOSE The purpose of this study was to compare the delivered dose to the expected intraoperative radiation therapy (IORT) dose with in vivo dosimetry. For IORT using electrons in accelerated partial breast irradiation, this is especially relevant since a high dose is delivered in a single fraction. METHODS For 47 of breast cancer patients, in vivo dosimetry was performed with MOSFETs and/or GAFCHROMIC EBT2 films. A total dose of 23.33 Gy at dmax was given directly after completing the lumpectomy procedure with electron beams generated with an IORT dedicated mobile accelerator. A protection disk was used to shield the thoracic wall. RESULTS The results of in vivo MOSFET dosimetry for 27 patients and GAFROMIC film dosimetry for 20 patients were analysed. The entry dose for the breast tissue, measured with MOSFETs, (mean value 22.3 Gy, SD 3.4%) agreed within 1.7% with the expected dose (mean value 21.9 Gy). The dose in breast tissue, measured with GAFCHROMIC films (mean value 23.50 Gy) was on average within 0.7% (SD = 3.7%, range -5.5% to 5.6%) of the prescribed dose of 23.33 Gy. CONCLUSIONS The dose measured with MOSFETs and GAFROMIC EBT2 films agreed well with the expected dose. For both methods, the dose to the thoracic wall, lungs and heart for left sided patents was lower than 2.5 Gy even when 12 MeV was applied. The positioning time of GAFCHROMIC films is negligible and based on our results we recommend its use as a standard tool for patient quality assurance during breast cancer IORT.

[1]  R. Pötter,et al.  Patient Selection for Accelerated Partial Breast Irradiation after Breast-conserving Surgery: Recommendations of the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) Breast Cancer Working Group , 2010 .

[2]  W. Spanos,et al.  Commissioning of a mobile electron accelerator for intraoperative radiotherapy , 2001, Journal of applied clinical medical physics.

[3]  R. Orecchia,et al.  Application of failure mode and effects analysis to intraoperative radiation therapy using mobile electron linear accelerators. , 2012, International journal of radiation oncology, biology, physics.

[4]  A. Micke,et al.  Multichannel film dosimetry with nonuniformity correction. , 2011, Medical physics.

[5]  J. Galvin,et al.  Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. , 1998, Medical physics.

[6]  Nada Tomic,et al.  Optimizing the dynamic range extension of a radiochromic film dosimetry system. , 2009, Medical physics.

[7]  A. Luini,et al.  Surgical technique of intraoperative radiation therapy with electrons (ELIOT) in breast cancer: a lesson learned by over 1000 procedures. , 2006, Surgery.

[8]  Maria F Chan,et al.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan. , 2012, Medical physics.

[9]  Norbert Ailleres,et al.  Electrons for intraoperative radiotherapy in selected breast-cancer patients: late results of the Montpellier phase II trial , 2013, Radiation oncology.

[10]  Swamidas V Jamema,et al.  Characterization of commercial MOSFET detectors and their feasibility for in-vivo HDR brachytherapy. , 2016, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[11]  A. Luini,et al.  In vivo dosimetry using radiochromic films during intraoperative electron beam radiation therapy in early-stage breast cancer. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  S. Mahdavi,et al.  Application of Gafchromic EBT2 film for intraoperative radiation therapy quality assurance. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[13]  M. Kathirvel,et al.  Is 5 mm MMLC suitable for VMAT‐based lung SBRT? A dosimetric comparison with 2.5 mm HDMLC using RTOG‐0813 treatment planning criteria for both conventional and high‐dose flattening filter‐free photon beams , 2015, Journal of applied clinical medical physics.

[14]  J. López-Tarjuelo,et al.  Implementation of an intraoperative electron radiotherapy in vivo dosimetry program , 2016, Radiation oncology.

[15]  Giuseppe Iaccarino,et al.  In vivo dosimetry with MOSFETs: dosimetric characterization and first clinical results in intraoperative radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[16]  A. Luini,et al.  Real-time in vivo dosimetry using micro-MOSFET detectors during intraoperative electron beam radiation therapy in early-stage breast cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  L. Menegotti,et al.  Monte Carlo investigation of breast intraoperative radiation therapy with metal attenuator plates. , 2007, Medical physics.

[18]  M. Benassi,et al.  Setup verification and in vivo dosimetry during intraoperative radiation therapy (IORT) for prostate cancer. , 2007, Medical physics.

[19]  F. Hensley Present state and issues in IORT Physics , 2017, Radiation oncology.

[20]  Slobodan Devic,et al.  Radiochromic film dosimetry: past, present, and future. , 2011, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[21]  Alphonse G. Taghian,et al.  Accelerated Partial Breast Irradiation: Executive summary for the update of an ASTRO Evidence-Based Consensus Statement. , 2017, Practical radiation oncology.

[22]  P. Aruna,et al.  Characterization of responses and comparison of calibration factor for commercial MOSFET detectors. , 2005, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[23]  J Cygler,et al.  Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter. , 1994, Medical physics.

[24]  M. Akbari,et al.  Dosimetric evaluation of Gafchromic EBT2 film for breast intraoperative electron radiotherapy verification. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[25]  M Ciocca,et al.  A preliminary report of intraoperative radiotherapy (IORT) in limited-stage breast cancers that are conservatively treated. , 2001, European journal of cancer.

[26]  T. Julian,et al.  Accelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO). , 2009, International journal of radiation oncology, biology, physics.

[27]  J. Chavaudra,et al.  Prescribing, Recording, and Reporting Electron Beam Therapy , 2004, Journal of the ICRU.

[28]  P. Koper,et al.  Single dose IOERT versus whole breast irradiation , 2016, Strahlentherapie und Onkologie.

[29]  Gary A Ezzell,et al.  Intraoperative radiation therapy using mobile electron linear accelerators: report of AAPM Radiation Therapy Committee Task Group No. 72. , 2006, Medical physics.