Influence of respiration-induced organ motion on dose distributions in treatments using enhanced dynamic wedges.

The mean velocity of respiration-induced organ motion in cranio-caudal direction is of the same magnitude as the velocity of the moving jaw during a treatment with an enhanced dynamic wedge. Therefore, if organ motion is present during collimator movement, the resulting dose distribution in wedge direction may differ from that obtained for the static case, i.e., without organ motion. The position as a function of time of the moving jaw has been derived from a log-file generated during each treatment. Parameters for the respiratory cycle and information about respiration-induced motion for organs in the upper abdomen were taken from the literature. Both movements were superimposed and the resulting monitor unit distribution has been calculated in the intrinsic coordinate system of the organ. The deviations from the static case have been studied as a function of wedge angle, amplitude of organ motion, respiratory rate, asymmetry of the respiratory cycle, beam energy, and the dose rate. If an amplitude of 30 mm and a respiratory rate of 10 min(-1) are assumed, the maximum deviation in monitor units is 2.5% for a 10 degees wedge, 7% for a 30 degrees wedge, and 16% for a 60 degrees wedge. Furthermore, a dose distribution for an organ undergoing respiration-induced motion has been generated and we found dose deviations of the same magnitude as calculated with the monitor unit distribution.

[1]  H. Mostafavi,et al.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. , 2000, Medical physics.

[2]  R C Grimm,et al.  Respiratory kinematics of the upper abdominal organs: A quantitative study , 1992, Magnetic resonance in medicine.

[3]  J. Battermann,et al.  The influence of respiration induced motion of the kidneys on the accuracy of radiotherapy treatment planning, a magnetic resonance imaging study. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  M. Aärimaa,et al.  Pancreatic mobility: an important factor in pancreatic computed tomography. , 1982, Journal of computer assisted tomography.

[5]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[6]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[7]  J. Gibbons,et al.  Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields. , 1998, Medical physics.

[8]  D D Leavitt,et al.  Dynamic wedge field techniques through computer-controlled collimator motion and dose delivery. , 1990, Medical physics.

[9]  E. Touboul,et al.  Kidney mobility during respiration. , 1994, Radiotherapy and Oncology.

[10]  H D Kubo,et al.  Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery. , 2000, Medical physics.

[11]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[12]  Ronald J. Jaszczak,et al.  60 Multimodality nuclear medicine imaging in radiation treatment planning for lung cancer: Challenges and prospects , 1996 .

[13]  L. Kuhns,et al.  Variation of Position of the Kidneys and Diaphragm in Patients Undergoing Repeated Suspension of Respiration , 1979, Journal of computer assisted tomography.

[14]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[15]  M. Halliwell,et al.  Ultrasound quantitation of respiratory organ motion in the upper abdomen. , 1994, The British journal of radiology.

[16]  B W Corn,et al.  Respiration-induced motion of the kidneys in whole abdominal radiotherapy: implications for treatment planning and late toxicity. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  J M Balter,et al.  Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors. , 1997, International journal of radiation oncology, biology, physics.

[18]  I. Suramo,et al.  Cranio-Caudal Movements of the Liver, Pancreas and Kidneys in Respiration , 1984, Acta radiologica: diagnosis.

[19]  J T Booth,et al.  Set-up error & organ motion uncertainty: a review. , 1999, Australasian physical & engineering sciences in medicine.