Inertial control as novel technique for in vitro gait simulations.

In vitro gait simulations are a preferential platform to study new intervention techniques or surgical procedures as they allow studying the isolated effect of surgical interventions. Commonly, simulations are performed by applying pre-defined setpoints for the kinetics and kinematics on all degrees of freedom (DOFs) of the cadaveric specimen. This however limits the applicability of the experiment to simulations for which pre-defined kinematics and kinetics can be measured in vivo. In this study we introduce inertial control as a new methodology for gait simulations that omits the need for pre-defined setpoints for the externally applied vertical ground reaction force (vGRF) and therefore allows the effect of interventions to be reflected upon it. Gait simulations of stance (1 s) were performed in 10 cadaveric specimens under three clinically relevant conditions: native ankle, total ankle prosthesis (TAP) and total ankle prosthesis plus triple arthrodesis (TAP+TA). In the native ankle, simulated vGRF was compared against the vGRF measured in vivo in 15 healthy volunteers and high correlations were found (R(2)=0.956, slope of regression line S=1.004). In TAP and TAP+TA, vGRF changed, therefore confirming the sensitivity of the method to kinematic constrains imposed with surgery. Inertial control can replicate in vivo kinetic conditions and allows investigating the isolated effect of surgical interventions on kinematic as well as kinetics.

[1]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[2]  Kim Parker,et al.  Gait analysis and functional outcomes following ankle arthrodesis for isolated ankle arthritis. , 2006, The Journal of bone and joint surgery. American volume.

[3]  Antonie J van den Bogert,et al.  Design and validation of a general purpose robotic testing system for musculoskeletal applications. , 2010, Journal of biomechanical engineering.

[4]  Vinzenz von Tscharner,et al.  Gait analysis in ankle osteoarthritis and total ankle replacement. , 2007, Clinical biomechanics.

[5]  Patrick M Aubin,et al.  Arthrodesis of the first metatarsophalangeal joint: a robotic cadaver study of the dorsiflexion angle. , 2010, The Journal of bone and joint surgery. American volume.

[6]  Kai Nan An,et al.  IN VITRO SIMULATION OF THE STANCE PHASE IN HUMAN GAIT , 2001 .

[7]  Benno M Nigg,et al.  Kinematic Changes After Fusion and Total Replacement of the Ankle Part 1: Range of Motion , 2003, Foot & ankle international.

[8]  Koen Peeters,et al.  An in vitro approach to the evaluation of foot-ankle kinematics: Performance evaluation of a custom-built gait simulator , 2013, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  A. Lundberg,et al.  Foot kinematics during walking measured using bone and surface mounted markers. , 2007, Journal of biomechanics.

[10]  William R. Ledoux,et al.  A Robotic Cadaveric Gait Simulator With Fuzzy Logic Vertical Ground Reaction Force Control , 2012, IEEE Transactions on Robotics.

[11]  F. Su,et al.  Gait analysis after ankle arthrodesis. , 2000, Gait & posture.

[12]  Christof Hurschler,et al.  In Vitro Simulation of Stance Phase Gait Part I: Model Verification , 2003, Foot & ankle international.

[13]  N. Sharkey,et al.  A dynamic cadaver model of the stance phase of gait: performance characteristics and kinetic validation. , 1998, Clinical biomechanics.

[14]  Eric C Whittaker,et al.  Foot bone kinematics as measured in a cadaveric robotic gait simulator. , 2011, Gait & posture.

[15]  Koen Peeters,et al.  Specimen-specific tibial kinematics model for in vitro gait simulations , 2013, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  Benno M Nigg,et al.  Kinematic Changes After Fusion and Total Replacement of the Ankle Part 2: Movement Transfer , 2003, Foot & ankle international.

[17]  Jim Richards,et al.  Biomechanics in clinic and research : an interactive teaching and learning course , 2008 .

[18]  Tina Herberts,et al.  Talonavicular arthrodesis or triple arthrodesis: Peak pressure in the adjacent joints measured in 8 cadaver specimens , 2007, Acta orthopaedica.

[19]  R A Mann,et al.  Arthrodesis of the First Metatarsophalangeal Joint , 1980, Foot & ankle.

[20]  William R. Ledoux,et al.  Second Toe in a Robotic Cadaveric Simulation of Gait Second Metatarsal Length is Positively Correlated with Increased Pressure and Medial Deviation of the , 2012 .