Analysis of high di/dt current pulses in three-level NPC inverters using series connected IGCTs and RC snubbers

High di/dt current pulses are harmful to the safety of IGCTs, especially to the low current conducting or freewheeling conducting IGCTs. This paper comprehensively analyzes the current pulses that flow through the inner switch of a three-level NPC inverter with series connected IGCTs and RC-snubbers. Four cases of high di/dt current pulses are addressed. The moments at which the high di/dt current pulses occur are clearly demonstrated. The value of the corresponding di/dt is estimated as well. The analysis is verified through simulation results using PSCAD/EMTDC. Based on the comprehensive analysis, the methods to handle these high di/dt current pulses are given respectively. An external re-trigger system is designed for a 6 kV/1800 kA three-level NPC inverter-fed medium voltage drive using series connected IGCTs. A more safe and reliable operation is reached for the series connected IGCTs in the three-level NPC inverter.

[1]  Wenhua Liu,et al.  6 kV/1800 kVA medium voltage drive with three-level NPC inverter using IGCTs , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[2]  P. Steimer,et al.  Design, simulation and realization of high power NPC converters equipped with IGCTs , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[3]  James Patrick Lyons,et al.  Innovation IGCT main drives , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[4]  P.K. Steimer,et al.  Characterization of IGCTs for series connected operation , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[5]  Hirofumi Akagi,et al.  A New Neutral-Point-Clamped PWM Inverter , 1981, IEEE Transactions on Industry Applications.

[6]  Dongsheng Zhou,et al.  Dead-time effect and compensations of three-level neutral point clamp inverters for high-performance drive applications , 1999 .