Control Method of Four Wire Active Power Filter Based on Three-Phase Neutral Point Clamped T-Type Converter

An active power filter based on a three-level neutral point clamped T-type converter with LCL input filter is presented in the paper. The main goal of the paper is the analysis of a control system that ensures independent control of a current in each phase. The presented control method of the filter allows reactive power compensation and/or a higher harmonics reduction to be achieved in each phase independently, with the possibility of control tan (φ) coefficient. This allows the power flow between the phases to be minimalized and reduces the RMS values of filter currents without the need to balance grid currents. The analysis presents the possibility of an operation in different modes, which was verified by experimental results. The results have been obtained in a 20 ARMS laboratory system described in the paper. The results reveal relatively low power losses, which are a feature of the selected three-level T-type topology. Additionally, that topology, when compared to a two-level one, ensures the reduction in current ripples with the same parameters of passive components.

[1]  Karol Fatyga,et al.  Frequency Estimation for Grid-Tied Inverters Using Resonant Frequency Estimator , 2021, Energies.

[2]  Kongpol Areerak,et al.  Harmonic Detection for Shunt Active Power Filter Using ADALINE Neural Network , 2021, Energies.

[3]  Mohd Amran Mohd Radzi,et al.  Shunt Active Power Filter: A Review on Phase Synchronization Control Techniques , 2019, Electronics.

[4]  Cosmin Darab,et al.  Management of Power Quality Issues from an Economic Point of View , 2018, Sustainability.

[5]  Mohd Amran Mohd Radzi,et al.  Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review , 2017 .

[6]  Suresh Mikkili,et al.  PHC, Id-Iq and p-q Control Strategies for Mitigation of Current Harmonics in Three-Phase Three-Wire Shunt Active Filter with PI Controller , 2017 .

[7]  V. K. Arun Shankar,et al.  Implementation of Shunt Active Filter for Harmonic Compensation in a 3 Phase 3 Wire Distribution Network , 2017 .

[8]  K. P. Sozanski,et al.  Three phase active power filter with selective harmonics elimination , 2016 .

[9]  D. K. Singh,et al.  Artificial Intelligence Based Control of a Shunt Active Power Filter , 2016 .

[10]  Cursino B. Jacobina,et al.  Multivariable load current sensorless controller for universal active power filter , 2014 .

[11]  A. Peer Fathima,et al.  A Technical Survey on Control Strategies of Active Filter for Harmonic Suppression , 2012 .

[12]  Surajit Chattopadhyay,et al.  Electric Power Quality , 2011 .

[13]  Fang Zheng Peng,et al.  Application issues of active power filters , 1998 .