Smart Semi-active PID-ACO control strategy for tower vibration reduction in Wind Turbines with MR damper

Wind turbine technology is well known around the globe as an eco-friendly and effective renewable power source. However, this technology often faces reliability problems due to structural vibration. This study proposes a smart semi-active vibration control system using Magnetorheological (MR) dampers where feedback controllers are optimized with nature-inspired algorithms. Proportional integral derivative (PID) and Proportional integral (PI) controllers are designed to achieve the optimal desired force and current input for MR the damper. PID control parameters are optimized using an Ant colony optimization (ACO) algorithm. The effectiveness of the ACO algorithm is validated by comparing its performance with Ziegler-Nichols (Z-N) and particle swarm optimization (PSO). The placement of the MR damper on the tower is also investigated to ensure structural balance and optimal desired force from the MR damper. The simulation results show that the proposed semi-active PID-ACO control strategy can significantly reduce vibration on the wind turbine tower under different frequencies (i.e., 67%, 73%, 79% and 34.4% at 2 Hz, 3 Hz, 4.6 Hz and 6 Hz, respectively) and amplitudes (i.e. 50%, 58% and 67% for 50 N, 80 N, and 100 N, respectively). In this study, the simulation model is validated with an experimental study in terms of natural frequency, mode shape and uncontrolled response at the 1st mode. The proposed PID-ACO control strategy and optimal MR damper position is also implemented on a lab-scaled wind turbine tower model. The results show that the vibration reduction rate is 66% and 73% in the experimental and simulation study, respectively, at the 1st mode.

[1]  Lu Liqiao,et al.  Control performance comparison between tuned liquid damper and tuned liquid column damper using real-time hybrid simulation , 2019, Earthquake Engineering and Engineering Vibration.

[2]  Saeed Tavakoli,et al.  Design of a decoupled PID controller via MOCS for seismic control of smart structures , 2016 .

[3]  Carlo L. Bottasso,et al.  Load mitigation for wind turbines by a passive aeroelastic device , 2016 .

[4]  Saeed Tavakoli,et al.  Optimal PD/PID control of smart base isolated buildings equipped with piezoelectric friction dampers , 2013, Earthquake Engineering and Engineering Vibration.

[5]  Søren Nielsen,et al.  Dynamics and Control of Lateral Tower Vibrations in Offshore Wind Turbines by Means of Active Generator Torque , 2014 .

[6]  Jianbing Chen,et al.  Shaking table test and numerical analysis of offshore wind turbine tower systems controlled by TLCD , 2015, Earthquake Engineering and Engineering Vibration.

[7]  Poul Henning Kirkegaard,et al.  Semiactive Vibration Control of a Wind Turbine Tower using an MR Damper , 2002 .

[8]  Gang S. Chen,et al.  Wind-induced instabilities and monitoring of wind turbine , 2019, Earthquake Engineering and Engineering Vibration.

[9]  Pierre-Yves Glorennec,et al.  Tuning fuzzy PID controllers using ant colony optimization , 2009, 2009 17th Mediterranean Conference on Control and Automation.

[10]  Y. Slavchev,et al.  Modeling and Control of Wind Turbine Tower Vibrations , 2010 .

[11]  Matthew J. Boucher,et al.  Active vibration control of a wind turbine blade using synthetic jets , 2009 .

[12]  Hamid Reza Karimi,et al.  Semiactive vibration control of offshore wind turbine towers with tuned liquid column dampers using H∞ output feedback control , 2010, 2010 IEEE International Conference on Control Applications.

[13]  Bogdan Sapiński,et al.  Vibration isolation using nonlinear damping implemented by a feedback-controlled MR damper , 2013 .

[14]  Jan Becker Høgsberg,et al.  Active tuned mass damper for damping of offshore wind turbine vibrations , 2017 .

[15]  Nicola Caterino,et al.  Real-time monitoring and structural control of a wind turbine using a rocking system , 2016, 2016 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS).

[16]  Zhi Chao Ong,et al.  A review of advances in magnetorheological dampers: their design optimization and applications , 2017 .

[17]  Biswajit Basu,et al.  Passive control of wind turbine vibrations including blade/tower interaction and rotationally sampled turbulence , 2008 .

[18]  Saeed Tavakoli,et al.  Control of piezoelectric friction dampers in smart base-isolated structures using self-tuning and adaptive fuzzy proportional–derivative controllers , 2017 .

[19]  Biswajit Basu,et al.  Tuned liquid column dampers in offshore wind turbines for structural control , 2009 .

[20]  Saeed Tavakoli,et al.  Fractional order PID control design for semi-active control of smart base-isolated structures: A multi-objective cuckoo search approach. , 2017, ISA transactions.

[21]  P. Martynowicz Study of vibration control using laboratory test rig of wind turbine tower-nacelle system with MR damper based tuned vibration absorber , 2016 .

[22]  Afzal Suleman,et al.  A comparative study of semi-active control strategies for base isolated buildings , 2015, Earthquake Engineering and Engineering Vibration.

[23]  I. Enevoldsen,et al.  Effects of a vibration mass damper in a wind turbine tower , 1996 .

[24]  Magdalene Marinaki,et al.  Vibration control of beams with piezoelectric sensors and actuators using particle swarm optimization , 2011, Expert Syst. Appl..

[25]  Rahmi Guclu,et al.  Seismic-vibration mitigation of a nonlinear structural system with an ATMD through a fuzzy PID controller , 2009 .

[26]  Bogdan Sapiński,et al.  MR damper based implementation of nonlinear damping for a pitch plane suspension system , 2012 .

[27]  S. Etedali,et al.  An Independent Robust Modal PID Control Approach for Seismic Control of Buildings , 2013 .

[28]  Maziah Mohamad,et al.  Continuous ant colony optimisation for active vibration control of flexible beam structures , 2011, 2011 IEEE International Conference on Mechatronics.

[29]  Qing Wang,et al.  Research on semi-active control method of a building structure based on non-smooth control , 2019, Earthquake Engineering and Engineering Vibration.

[30]  Saeed Tavakoli,et al.  Adaptive fractional order fuzzy proportional–integral–derivative control of smart base-isolated structures equipped with magnetorheological dampers , 2017 .

[31]  Saeed Tavakoli,et al.  Online tuning of fractional order fuzzy PID controller in smart seismic isolated structures , 2018, Bulletin of Earthquake Engineering.

[32]  Sadegh Etedali,et al.  A hybrid LQR-PID control design for seismic control of buildings equipped with ATMD , 2018 .

[33]  Saeed Tavakoli,et al.  PD/PID Controller Design for Seismic Control of High-Rise Buildings Using Multi-Objective Optimization: A Comparative Study with LQR Controller , 2017 .

[34]  Shin Yee Khoo,et al.  Performance enhancement of wind turbine systems with vibration control: A review , 2015 .

[35]  Marina Schroder,et al.  Structural Control Past Present And Future , 2016 .

[36]  Paweł Martynowicz,et al.  Development of Laboratory Model of Wind Turbine's Tower-Nacelle System with Magnetorheological Tuned Vibration Absorber , 2013 .

[37]  Seyed Amin Mousavi,et al.  Contribution of tuned liquid column gas dampers to the performance of offshore wind turbines under wind, wave, and seismic excitations , 2016, Earthquake Engineering and Engineering Vibration.

[38]  Biswajit Basu,et al.  Dynamics and control of vibrations in wind turbines with variable rotor speed , 2013 .

[39]  S. Krenk,et al.  Resonant vibration control of three-bladed wind turbine rotors , 2012 .

[40]  Shirley J. Dyke,et al.  PHENOMENOLOGICAL MODEL FOR MAGNETORHEOLOGICAL DAMPERS , 1997 .

[41]  Rahmi Guclu,et al.  Sliding mode and PID control of a structural system against earthquake , 2006, Math. Comput. Model..

[42]  Paweł Martynowicz Vibration control of wind turbine tower-nacelle model with magnetorheological tuned vibration absorber , 2017 .

[43]  Mario A. Rotea,et al.  Passive structural control of offshore wind turbines , 2011 .

[44]  Pierre Borne,et al.  Tuning PID Controller Using Multiobjective Ant Colony Optimization , 2012, Appl. Comput. Intell. Soft Comput..

[45]  Saeed Tavakoli,et al.  A GBMO-based PI λ D μ controller for vibration mitigation of seismic-excited structures , 2018 .

[46]  Meysam Ramezani,et al.  Application of artificial neural networks in optimal tuning of tuned mass dampers implemented in high-rise buildings subjected to wind load , 2018, Earthquake Engineering and Engineering Vibration.