Influence of fan-shaped non-uniform pollution on the electrical property of typical type HVDC insulator and insulation selection

Affected by long-term crosswind, insulator surface will get coated with fan-shaped non-uniform pollution, which lowers insulator flashover voltage as previous study revealed. In this study, a further research in specific to HVDC line insulation is presented. Taking typical dc insulator as the sample, its dc flashover performance under fan-shaped non-uniform pollution was tested. Then the influence of that kind non-uniformity was investigated through analysing the pollution layer residual resistance, the flashover process and critical flashover voltage. Finally the relevant HVDC insulation selection was made. Research results indicate that: under fan-shaped non-uniform pollution, insulator flashover voltage ( U 50) gets impaired, and is more obviously impaired by ratio J of windward to leeward side salt deposit density (SDD) than leeward side area proportion T ; under various T and J , there is still an exponential relationship between U 50 and SDD; under fan-shaped non-uniform pollution the pollution layer residual resistance decreases, which theoretically promotes the arc propagation and flashover process, and thus finally lowers flashover voltage; for the transmission line in area with fan-shaped non-uniform pollution, adding insulator units to strengthen the withstand property are needed.

[1]  K. Naito,et al.  Improvement of the DC voltage insulation efficiency of suspension insulators under contaminated conditions , 1988 .

[2]  W. Lampe,et al.  Long-term tests of HVDC insulators under natural pollution conditions at the Big Eddy Test Center , 1989 .

[3]  Ruobing Zhang,et al.  Calculation of DC and AC flashover voltage of polluted insulators , 1990 .

[4]  R. S. Gorur,et al.  Effect of insulator profiles on DC flashover voltage under polluted conditions. A study using a dynamic arc model , 1994 .

[5]  F. Rizk,et al.  Modeling of altitude effects on AC flashover of polluted high voltage insulators , 1997 .

[6]  R. T. Waters,et al.  Formation and characterization of dry bands in clean fog on polluted insulators , 1999, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  F. Topalis,et al.  Dielectric behaviour of polluted porcelain insulators , 2001 .

[8]  Holtzhausen Jp,et al.  The pollution flashover of ac energized post type insulators , 2001 .

[9]  H. Salazar,et al.  Artificial neural networks and clustering techniques applied in the reconfiguration of distribution systems , 2006, IEEE Transactions on Power Delivery.

[10]  Jianlin Hu,et al.  Study on Pollution Flashover Performance of Short Samples of Composite Insulators Intended for /spl plusmn/800 kV UHV DC , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  M. A. Douar,et al.  Flashover process and frequency analysis of the leakage current on insulator model under non-uniform pollution conditions , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  Caixin Sun,et al.  Study on DC Pollution Flashover Performance of Various Types of Long String Insulators Under Low Atmospheric Pressure Conditions , 2010, IEEE Transactions on Power Delivery.

[13]  Xingliang Jiang,et al.  Investigation of flashover voltage and non-uniform pollution correction coefficient of short samples of composite insulator intended for ±800kV UHVDC , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Caixin Sun,et al.  Study of the influence of test methods on DC pollution flashover voltage of insulator strings and its flashover process , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  A. Beroual,et al.  Analytical computation of discharge characteristic constants and critical parameters of flashover of polluted insulators , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  R T Waters,et al.  Partial-arc and spark models of the flashover of lightly polluted insulators , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[17]  M. Slama,et al.  Influence of the linear non-uniformity of pollution layer on the insulator flashover under impulse voltage - estimation of the effective pollution thickness , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  Lin Yang,et al.  Comparison of pollution flashover performance of porcelain long rod, disc type, and composite UHVDC insulators at high altitudes , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  Xingliang Jiang,et al.  Study on AC Flashover Performance for Different Types of Porcelain and Glass Insulators With Non-Uniform Pollution , 2013, IEEE Transactions on Power Delivery.

[20]  Xingliang Jiang,et al.  DC flashover performance of insulator string with fan-shaped non-uniform pollution , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[21]  Xingliang Jiang,et al.  Study on the DC Flashover Performance of Various Types of Insulators With Fan-Shaped Nonuniform Pollution , 2015, IEEE Transactions on Power Delivery.

[22]  Xingliang Jiang,et al.  Effects of pollution materials on the AC flashover performance of suspension insulators , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.