Can MR Measurement of Renal Artery Flow and Renal Volume Predict the Outcome of Percutaneous Transluminal Renal Angioplasty?

AbstractPurpose: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA. Methods: The data on 23 patients (13 men, 10 women; age range 47–82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold, cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm3). Results: Clinical success was observed in 11 patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm3 predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm3 identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001).Conclusion: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.

[1]  D. Leung,et al.  Magnetic resonance angiography versus duplex sonography for diagnosing renovascular disease. , 1999, Hypertension.

[2]  F H Derkx,et al.  Renal artery stenosis and hypertension. , 1994, Lancet.

[3]  J. Laragh,et al.  Percutaneous transluminal renal angioplasty in renovascular hypertension due to atheroma or fibromuscular dysplasia. , 1983, The New England journal of medicine.

[4]  Pierre-François Plouin,et al.  Blood pressure outcome of angioplasty in atherosclerotic renal artery stenosis: a randomized trial. Essai Multicentrique Medicaments vs Angioplastie (EMMA) Study Group. , 1998, Hypertension.

[5]  A. Morganti,et al.  Angioplasty of atherosclerotic and fibromuscular renal artery stenosis: time course and predicting factors of the effects on renal function. , 2000, American journal of hypertension.

[6]  L. Axel,et al.  Renal artery stenosis: evaluation with conventional angiography versus gadolinium-enhanced MR angiography. , 1999, Radiology.

[7]  D. Strandness Natural history of renal artery stenosis. , 1994, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[8]  D. Leung,et al.  Characterization of renal artery stenoses based on magnetic resonance renal flow and volume measurements. , 1999, Kidney international.

[9]  H. Haimovici,et al.  Experimental renal-artery stenosis diagnostic significance of arterial hemodynamics. , 1962, The Journal of cardiovascular surgery.

[10]  M Bock,et al.  Renal artery stenosis: grading of hemodynamic changes with cine phase-contrast MR blood flow measurements. , 1997, Radiology.

[11]  J. Edwards,et al.  Role of duplex scanning for the detection of atherosclerotic renal artery disease. , 1991, Kidney international.

[12]  E E de Lange,et al.  Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging. , 1999, Radiology.

[13]  D. E. Strandness,et al.  Natural history of atherosclerotic renal artery stenosis: a prospective study with duplex ultrasonography. , 1994, Journal of vascular surgery.

[14]  W. Mali,et al.  Arterial stenting and balloon angioplasty in ostial atherosclerotic renovascular disease: a randomised trial , 1999, The Lancet.

[15]  J. Webster,et al.  Randomised comparison of percutaneous angioplasty vs continued medical therapy for hypertensive patients with atheromatous renal artery stenosis , 1998, Journal of Human Hypertension.

[16]  P. Sheedy,et al.  Renal artery angioplasty: technical results and clinical outcome in 320 patients. , 1995, Mayo Clinic proceedings.

[17]  Novick Ac Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty. , 1997 .

[18]  S. Bergentz Natural history of renal artery stenosis. , 1992, Annales chirurgiae et gynaecologiae.

[19]  R. Volkmann,et al.  Treatment of renovascular hypertension: one year results of renal angioplasty. , 1995, Kidney international.

[20]  W. Flinn,et al.  Can intrarenal duplex waveform analysis predict successful renal artery revascularization? , 1998, Journal of vascular surgery.

[21]  J. Debatin MR quantification of flow in abdominal vessels , 1998, Abdominal Imaging.

[22]  T. Chenevert,et al.  Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. , 1995, Radiology.

[23]  T. Lehnert,et al.  Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty. , 1997, The New England journal of medicine.

[24]  P. Fauchald,et al.  Percutaneous Transluminal Renal Artery Angioplasty Using the Coaxial Technique , 1998, Acta radiologica.

[25]  E E de Lange,et al.  In vitro measurement of kidney size: comparison of ultrasonography and MRI. , 1998, Ultrasound in medicine & biology.

[26]  J. Debatin,et al.  Value of image subtraction in 3D gadolinium‐enhanced MR angiography of the renal arteries , 1998, Journal of magnetic resonance imaging : JMRI.

[27]  M. Bettmann,et al.  Outcome and cost comparison of percutaneous transluminal renal angioplasty, renal arterial stent placement, and renal arterial bypass grafting. , 1999, Radiology.

[28]  N J Pelc,et al.  Renal artery blood flow: quantitation with phase-contrast MR imaging with and without breath holding. , 1994, Radiology.

[29]  S. Goldman Renal artery angioplasty: technical results and clinical outcome in 320 patients. , 1996, The Journal of urology.