Simulation of water column separation in Francis pump-turbine draft tube

The paper presents the modelling, simulation and analysis of the transient behaviour of a 340 MW pump-turbine in case of emergency shutdown in turbine mode with focus on possible draft tube water column separation. The model of a pumped storage power plant with simplified layout is presented. This model includes a penstock feeding one 340MW pump-turbine with the related rotating inertia and a tailrace tunnel. The model of the tailrace tunnel allowing for water column separation simulation is introduced. The simulation results of the transient behaviour of the pump-turbine in case of emergency shutdown in generating mode, with and without downstream water column separation model are presented for different degree of severity triggered by the submergence and the tailrace tunnel length. The amplitudes of the pressure peaks induced by the cavity collapse are analysed with respect to the pressure drop magnitude and tailrace dimensions. The maximum and minimum pressure amplitudes obtained along the tailrace tunnel are analysed for different test case conditions.

[1]  Giuseppe Pezzinga,et al.  Second viscosity in transient cavitating pipe flows , 2003 .

[2]  O. H. Souza,et al.  Study of hydraulic transients in hydropower plants through simulation of nonlinear model of penstock and hydraulic turbine model , 1999 .

[3]  E. Benjamin Wylie,et al.  Fluid Transients in Systems , 1993 .

[4]  Alain Sapin Logiciel modulaire pour la simulation et l"étude des systèmes d"entraînement et des réseaux électriques , 1995 .

[5]  Christophe Nicolet,et al.  Hydroacoustic modelling and numerical simulation of unsteady operation of hydroelectric systems , 2007 .

[6]  Angus R. Simpson,et al.  Water hammer with column separation: A historical review , 2006 .

[7]  François Avellan,et al.  Identification of Francis Turbine Helical Vortex Rope Excitation by CFD and Resonance Simulation With the Hydraulic System , 2011 .

[8]  Christophe NICOLET,et al.  Cavitation and Dynamic Problems in Hydraulic Machinery and Systems , October , 26-28 , 2011 , Belgrade , Serbia Simulation of Water Hammer Induced Column Separation through Electrical Analogy , 2011 .

[9]  Daniel Himr,et al.  Simulation of low pressure water hammer , 2010 .

[10]  Angus R. Simpson,et al.  Pipeline column separation flow regimes , 1999 .

[11]  Christophe Nicolet,et al.  Parametric study of water column separation in Francis pump-turbine draft tube , 2011 .

[12]  Jim C. P. Liou,et al.  Numerical Properties of the Discrete Gas Cavity Model for Transients , 2000 .

[13]  E. Benjamin Wylie,et al.  Simulation of Vaporous and Gaseous Cavitation , 1984 .

[14]  François Avellan,et al.  Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes , 2008 .