Scintillation Detection with Large-Area Reach-Through Avalanche Photodiodes

Silicon avalanche photodiodes of the "reach-through" type have been used as scintillation detectors with device performance closely approaching that of PMT's. The device consists of a 6 × 6mm diode with a 5 × 5mm photosensitive area in a 6.7 × 6.7 × 2.0mm package which is suitable for mounting in an array. Typical characteristics at room temperature are: quantum efficiency ¿50% at ¿=415nm; surface dark current <200nA; bulk dark-current (before gain) <1nA; noise current (at optimum gain of 20 to 50) <1pA/Hz¿; response time <5ns; capacitance ¿21pF; biasing voltage ¿200-400 Volts. When coupled to a NaI(Tl) scintillator (9 × 9 × 38mm) photo-peak resolutions (FWHM) for 662keV radiation of 10.4% at 21°C and 9.8% at 0°C were measured. The measured noise equivalent primary charge of one detector at a gain of 50 was 121 electrons (51 electrons rms) at room temperature. The significance of this new detector to high resolution imaging systems and detector arrays is discussed.

[1]  Douglas P. Boyd Status of Diagnostic X-Ray CT: 1979 , 1979, IEEE Transactions on Nuclear Science.

[2]  R. Mcintyre,et al.  Multi-element reachthrough avalanche photodiodes , 1984, IEEE Transactions on Electron Devices.

[3]  J. Schweitzer,et al.  Temperature Dependence of NaI(Tl) Decay Constant , 1983, IEEE Transactions on Nuclear Science.

[4]  R. Mcintyre,et al.  Large Area Reach-Through Avalanche Diodes for X-Ray Spectroscopy , 1976, IEEE Transactions on Nuclear Science.

[5]  J. Iwanczyk,et al.  A Study of Low-Noise Preamplifier Systems for Use with Room Temperature Mercuric Iodide (Hgi2) X-Ray Detectors , 1981, IEEE Transactions on Nuclear Science.

[6]  G. Entine,et al.  Scintillation Detectors Using Large Area Silicon Avalanche Photodiodes , 1983, IEEE Transactions on Nuclear Science.

[7]  Thomas F. Budinger,et al.  High Resolution Positron Emission Tomography Using Small Bismuth Germanate Crystals and Individual Photosensors , 1983 .

[8]  J. B. Barton,et al.  A High Resolution Detection System for Positron Tomography , 1983, IEEE Transactions on Nuclear Science.

[9]  R. Mcintyre Multiplication noise in uniform avalanche diodes , 1966 .

[10]  J. L. Blankenship Design of Low-Noise Vacuum-Tube Pulse Amplifiers for Semiconductor Radiation-Detector Spectroscopy , 1964 .

[11]  C. Nahmias,et al.  Optimization of Crystal Size in Emission Computerized Tomography , 1980, IEEE Transactions on Nuclear Science.

[12]  C. Fan Detection of scintillation photons with photodiodes , 1964 .

[13]  S. Derenzo,et al.  Monte Carlo Calculations of the Optical Coupling between Bismuth Germanate Crystals and Photomultiplier Tubes , 1982, IEEE Transactions on Nuclear Science.

[14]  D. Chesler,et al.  A Positron Tomograph Employing a One Dimension BGO Scintillation Camera , 1983, IEEE Transactions on Nuclear Science.