Automated microaneurysm detection in diabetic retinopathy using curvelet transform

Abstract. Microaneurysms (MAs) are known to be the early signs of diabetic retinopathy (DR). An automated MA detection system based on curvelet transform is proposed for color fundus image analysis. Candidates of MA were extracted in two parallel steps. In step one, blood vessels were removed from preprocessed green band image and preliminary MA candidates were selected by local thresholding technique. In step two, based on statistical features, the image background was estimated. The results from the two steps allowed us to identify preliminary MA candidates which were also present in the image foreground. A collection set of features was fed to a rule-based classifier to divide the candidates into MAs and non-MAs. The proposed system was tested with Retinopathy Online Challenge database. The automated system detected 162 MAs out of 336, thus achieved a sensitivity of 48.21% with 65 false positives per image. Counting MA is a means to measure the progression of DR. Hence, the proposed system may be deployed to monitor the progression of DR at early stage in population studies.

[1]  I. Immonen,et al.  Disappearance and formation rates of microaneurysms in early diabetic retinopathy. , 1996, The British journal of ophthalmology.

[2]  Jean-Claude Klein,et al.  Automatic Detection Of Microaneurysms In Retinopathy Fluoro-Angiogram , 1984, Optics + Photonics.

[3]  R. C. Turner,et al.  Microaneurysms in the development of diabetic retinopathy (UKPDS 42) , 1999, Diabetologia.

[4]  A. Rouse,et al.  Multispectral imaging with a confocal microendoscope. , 2000, Optics letters.

[5]  Bram van Ginneken,et al.  Automatic detection of red lesions in digital color fundus photographs , 2005, IEEE Transactions on Medical Imaging.

[6]  Bálint Antal,et al.  An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading , 2012, IEEE Transactions on Biomedical Engineering.

[7]  Peter F Sharp,et al.  A fully automated comparative microaneurysm digital detection system , 1997, Eye.

[8]  J. Klein,et al.  Automatic detection of microaneurysms in diabetic fluorescein angiography. , 1984, Revue d'epidemiologie et de sante publique.

[9]  Janet Liversidge,et al.  What determines the site of inflammation in uveitis and chorioretinitis? , 1997, Eye.

[10]  S. Abdelazeem,et al.  Micro-aneurysm detection using vessels removal and circular Hough transform , 2002, Proceedings of the Nineteenth National Radio Science Conference.

[11]  Thomas Walter,et al.  Automatic Detection of Microaneurysms in Color Fundus Images of the Human Retina by Means of the Bounding Box Closing , 2002, ISMDA.

[12]  Pascale Massin,et al.  Automatic detection of microaneurysms in color fundus images , 2007, Medical Image Anal..

[13]  Cheryl N. Zimmer,et al.  Innovation in Diagnostic Retinal Imaging: Multispectral Imaging Multiple-wavelength imaging of the retina and choroid. , 2014 .

[14]  Roberto Marcondes Cesar Junior,et al.  Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification , 2005, IEEE Transactions on Medical Imaging.

[15]  Sharib Ali,et al.  Automated detection of microaneurysms using scale-adapted blob analysis and semi-supervised learning , 2014, Comput. Methods Programs Biomed..

[16]  Martin Ehler Modifications of iterative schemes used for curvature correction in noninvasive biomedical imaging , 2013, Journal of biomedical optics.

[17]  Wojciech Czaja,et al.  Schroedinger Eigenmaps for the Analysis of Biomedical Data , 2011, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[18]  Qin Li,et al.  Retinopathy Online Challenge: Automatic Detection of Microaneurysms in Digital Color Fundus Photographs , 2010, IEEE Transactions on Medical Imaging.

[19]  Janis Spigulis,et al.  Towards noncontact skin melanoma selection by multispectral imaging analysis. , 2011, Journal of biomedical optics.

[20]  Augustinus Laude,et al.  Automated Detection of Microaneurysms Using Curvelet Transform , 2015 .

[21]  Martin Ehler,et al.  Principal component model of multispectral data for near real-time skin chromophore mapping. , 2010, Journal of biomedical optics.

[22]  Augustinus Laude,et al.  Making every microaneurysm count: A hybrid approach to monitor progression of diabetic retinopathy , 2014, 2014 5th International Conference on Intelligent and Advanced Systems (ICIAS).

[23]  András Hajdu,et al.  Retinal Microaneurysm Detection Through Local Rotating Cross-Section Profile Analysis , 2013, IEEE Transactions on Medical Imaging.

[24]  Lucia Dettori,et al.  A comparison of wavelet, ridgelet, and curvelet-based texture classification algorithms in computed tomography , 2007, Comput. Biol. Medicine.

[25]  Gwénolé Quellec,et al.  Optimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs , 2008, IEEE Transactions on Medical Imaging.

[26]  José Cunha-Vaz,et al.  Microaneurysm turnover in the macula is a biomarker for development of clinically significant macular edema in type 2 diabetes , 2013 .

[27]  Samir Brahim Belhaouari,et al.  Breast cancer diagnosis in digital mammogram using multiscale curvelet transform , 2010, Comput. Medical Imaging Graph..

[28]  Laurent Demanet,et al.  Fast Discrete Curvelet Transforms , 2006, Multiscale Model. Simul..

[29]  F H Davidorf,et al.  Scanning electron microscopic study of microaneurysms in the diabetic retina. , 1991, Annals of ophthalmology.

[30]  Yupeng Xu,et al.  A light‐emitting diode (LED)‐based multispectral imaging system in evaluating retinal vein occlusion , 2015, Lasers in surgery and medicine.

[31]  P. Sharp,et al.  Automated detection and quantification of microaneurysms in fluorescein angiograms , 2004, Graefe's Archive for Clinical and Experimental Ophthalmology.

[32]  Julia A. Dobrosotskaya,et al.  Modeling Photo-Bleaching Kinetics to Create High Resolution Maps of Rod Rhodopsin in the Human Retina , 2015, PloS one.

[33]  Felipe Orihuela-Espina,et al.  Quantitative analysis of multi-spectral fundus images , 2006, Medical Image Anal..

[34]  Chun Yuan,et al.  In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques. , 2002 .

[35]  Andras Hajdu,et al.  Retinal Microaneurysm Detection Based on Intensity Profile Analysis , 2010 .

[36]  Atsushi Mizutani,et al.  Automated microaneurysm detection method based on double ring filter in retinal fundus images , 2009, Medical Imaging.

[37]  M. Abràmoff,et al.  Web-based screening for diabetic retinopathy in a primary care population: the EyeCheck project. , 2005, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[38]  E. Candès,et al.  Curvelets: A Surprisingly Effective Nonadaptive Representation for Objects with Edges , 2000 .

[39]  Max Q.-H. Meng,et al.  Texture analysis for ulcer detection in capsule endoscopy images , 2009, Image Vis. Comput..

[40]  Gerlind Plonka-Hoch,et al.  The Curvelet Transform , 2010, IEEE Signal Processing Magazine.

[41]  Qin Li,et al.  Detection of microaneurysms using multi-scale correlation coefficients , 2010, Pattern Recognit..

[42]  Alejandro F. Frangi,et al.  Muliscale Vessel Enhancement Filtering , 1998, MICCAI.

[43]  Ali Mahlooji Far,et al.  Retinal Image Analysis Using Curvelet Transform and Multistructure Elements Morphology by Reconstruction , 2011, IEEE Transactions on Biomedical Engineering.

[44]  Roberto Marcondes Cesar Junior,et al.  Retinal Vessel Segmentation Using the 2-D Morlet Wavelet and Supervised Classification , 2005, ArXiv.

[45]  R. Klein,et al.  Retinal microaneurysm counts and 10-year progression of diabetic retinopathy. , 1995, Archives of ophthalmology.