Development of a High-Linearity Voltage and Current Probe with a Floating Toroidal Coil: Principle, Demonstration, Design Optimization, and Evaluation

As the conventional voltage and current (VI) probes widely used in plasma diagnostics have separate voltage and current sensors, crosstalk between the sensors leads to degradation of measurement linearity, which is related to practical accuracy. Here, we propose a VI probe with a floating toroidal coil that plays both roles of a voltage and current sensor and is thus free from crosstalk. The operation principle and optimization conditions of the VI probe are demonstrated and established via three-dimensional electromagnetic wave simulation. Based on the optimization results, the proposed VI probe is fabricated and calibrated for the root-mean-square (RMS) voltage and current with a high-voltage probe and a vector network analyzer. Then, it is evaluated through a comparison with a commercial VI probe, with the results demonstrating that the fabricated VI probe achieved a slightly higher linearity than the commercial probe: R2 of 0.9967 and 0.9938 for RMS voltage and current, respectively. The proposed VI probe is believed to be applicable to plasma diagnostics as well as process monitoring with higher accuracy.

[1]  S. Kim,et al.  Crossing Frequency Method Applicable to Intermediate Pressure Plasma Diagnostics Using the Cutoff Probe , 2022, Sensors.

[2]  S. Kim,et al.  Various evolution trends of sample thickness in fluorocarbon film deposition on SiO2 , 2022, Journal of Vacuum Science & Technology A.

[3]  S. Kim,et al.  Characterization of SiO2 Over Poly-Si Mask Etching in Ar/C4F8 Capacitively Coupled Plasma , 2021, Applied Science and Convergence Technology.

[4]  S. Kim,et al.  Characterization of SiO2 Etching Profiles in Pulse-Modulated Capacitively Coupled Plasmas , 2021, Materials.

[5]  D. Farmer,et al.  Plasma processing for advanced microelectronics beyond CMOS , 2021, Journal of Applied Physics.

[6]  J. J. Lee,et al.  Finding the optimum design of the planar cutoff probe through a computational study , 2021 .

[7]  V. Godyak RF discharge diagnostics: Some problems and their resolution , 2021 .

[8]  Y. Choi,et al.  Anti-contamination SMART (Spectrum Monitoring Apparatus with Roll-to-roll Transparent film) window for optical diagnostics of plasma systems. , 2021, The Review of scientific instruments.

[9]  R. Brinkmann,et al.  Kinetic investigation of the planar multipole resonance probe in the low-pressure plasma , 2019, Plasma Sources Science and Technology.

[10]  D. Ogawa,et al.  Experimental validity of double-curling probe method in film-depositing plasma , 2021 .

[11]  T. Nozaki,et al.  The 2020 plasma catalysis roadmap , 2020, Journal of Physics D: Applied Physics.

[12]  C. Chung,et al.  A method for measuring negative ion density distribution using harmonic currents in a low-pressure oxygen plasma , 2020, Plasma Sources Science and Technology.

[13]  R. Engeln,et al.  Foundations of optical diagnostics in low-temperature plasmas , 2020, Plasma Sources Science and Technology.

[14]  M. Hrabovsky,et al.  Modified high frequency probe approach for diagnostics of highly reactive plasma , 2019, Plasma Sources Science and Technology.

[15]  S. Kim,et al.  Development of High-precision RF Sensor , 2019, Applied Science and Convergence Technology.

[16]  J. J. Lee,et al.  A transmission line model of the cutoff probe , 2019, Plasma Sources Science and Technology.

[17]  Keiji Nakamura,et al.  Recent innovations in microwave probes for reactive plasma diagnostics , 2019, Japanese Journal of Applied Physics.

[18]  Chih-Yuan Lu,et al.  Study of Plasma Arcing Mechanism in High Aspect Ratio Slit Trench Etching , 2019, 2019 30th Annual SEMI Advanced Semiconductor Manufacturing Conference (ASMC).

[19]  K. Kim,et al.  An in situ monitoring method for PECVD process equipment condition , 2019, Plasma Science and Technology.

[20]  D. Mocuta,et al.  Progress in nanoscale dry processes for fabrication of high-aspect-ratio features: How can we control critical dimension uniformity at the bottom? , 2018 .

[21]  E. Moreau,et al.  The 2017 Plasma Roadmap: Low temperature plasma science and technology , 2017 .

[22]  Robert B. Lobbia,et al.  Recommended Practice for Use of Langmuir Probes in Electric Propulsion Testing , 2017 .

[23]  Moreau,et al.  Plasma Roadmap : Low temperature plasma science and technology , 2017 .

[24]  A. Pathak,et al.  Paschen curve approach to investigate electron density and deposition rate of Cu in magnetron sputtering system , 2016 .

[25]  M. Vasudev,et al.  Plasma-Enhanced Chemical Vapor Deposition: Where we are and the Outlook for the Future , 2016 .

[26]  T. Nozawa,et al.  Characterization of CO2 plasma ashing for less low-dielectric-constant film damage , 2015 .

[27]  C. Chung,et al.  Electron heating and control of electron energy distribution for the enhancement of the plasma ashing processing , 2015 .

[28]  F. Uesugi,et al.  Real-time characteristic impedance monitoring for end-point and anomaly detection in the plasma etching process , 2014 .

[29]  Jie Yang,et al.  Dimension Reduction of Multivariable Optical Emission Spectrometer Datasets for Industrial Plasma Processes , 2013, Sensors.

[30]  Vincent M. Donnelly,et al.  Plasma etching: Yesterday, today, and tomorrow , 2013 .

[31]  G. May,et al.  Use of In-Situ Optical Emission Spectroscopy for Leak Fault Detection and Classification in Plasma Etching , 2013 .

[32]  P. Awakowicz,et al.  Process diagnostics and monitoring using the multipole resonance probe in an inhomogeneous plasma for ion-assisted deposition of optical coatings , 2013 .

[33]  R. Naik,et al.  Exploration of plasma-enhanced chemical vapor deposition as a method for thin-film fabrication with biological applications. , 2013, ACS applied materials & interfaces.

[34]  J. Booth,et al.  Radio frequency current-voltage probe for impedance and power measurements in multi-frequency unmatched loads. , 2013, The Review of scientific instruments.

[35]  D. Carter,et al.  Managing arcs in large area sputtering applications , 2012 .

[36]  Rongshun Chen,et al.  Real-Time Fault Classification for Plasma Processes , 2011, Sensors.

[37]  Rongshun Chen,et al.  Real-Time Plasma Process Condition Sensing and Abnormal Process Detection , 2010, Sensors.

[38]  Sbs Stephan Heil,et al.  Optical emission spectroscopy as a tool for studying, optimizing, and monitoring plasma-assisted atomic layer deposition processes , 2010 .

[39]  C. Ye,et al.  ANALYSIS OF OPTICAL EMISSION SPECTROSCOPY IN A DUAL-FREQUENCY CAPACITIVELY COUPLED CHF3 PLASMA , 2009 .

[40]  Chin-Wook Chung,et al.  Floating probe for electron temperature and ion density measurement applicable to processing plasmas , 2007 .

[41]  J. Booth,et al.  A novel technique for plasma density measurement using surface-wave transmission spectra , 2005 .

[42]  Han-Ku Cho,et al.  Chamber maintenance and fault detection technique for a gate etch process via self-excited electron resonance spectroscopy , 2005 .

[43]  Benjamin Alexandrovich,et al.  The hairpin resonator: A plasma density measuring technique revisited , 2004 .

[44]  C. Wolden,et al.  Investigation of the role of plasma conditions on the deposition rate and electrochromic performance of tungsten oxide thin films , 2003 .

[45]  Nasim Ahmed Dewan Analysis and modelling of the impact of plasma RF harmonics in semiconductor plasma processing , 2001 .

[46]  J. Lawler,et al.  Plasma diagnostics in industry , 2000 .

[47]  S. Samukawa,et al.  Effects of Ar dilution on the optical emission spectra of fluorocarbon ultrahigh-frequency plasmas: C4F8 vs CF4 , 1999 .

[48]  A. Lichtenberg,et al.  Principles of Plasma Discharges and Materials Processing , 1994 .

[49]  Mark A. Sobolewski,et al.  Electrical characterization of radio‐frequency discharges in the Gaseous Electronics Conference Reference Cell , 1992 .