Phase ordering with automatic window selection (PAWS): A novel motion‐resistant technique for 3D coronary imaging

Navigator acceptance imaging methods are hindered by the loss in scan efficiency which results from the changes in the breathing pattern of a subject over time. The diminishing variance algorithm (DVA), which does not use a predefined acceptance window, is less influenced by such changes. The use of phase ordering and weighting techniques has been shown to significantly improve image quality over nonordered window methods. However, the use of an acceptance window is inherent in all these techniques as a decision to accept or reject data must still be made. A technique is presented which is resistant to changes in breathing while allowing the use of phase ordering to provide effective motion artifact reduction in optimal time. The basic principle is described and illustrated for this automatic window‐selection technique with in vitro results to demonstrate the feasibility of this method. Results of an in vivo study are also presented which demonstrate significant improvement in image quality over the DVA (p < 0.01) and hybrid‐ordered phase encoding methods (p < 0.05). Magn Reson Med 43:470–480, 2000. © 2000 Wiley‐Liss, Inc.

[1]  J Keegan,et al.  3D coronary artery imaging with phase reordering for improved scan efficiency , 1999, Magnetic resonance in medicine.

[2]  P Börnert,et al.  Motion pattern adapted real‐time respiratory gating , 1999, Magnetic resonance in medicine.

[3]  J Keegan,et al.  Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction , 1998, Journal of magnetic resonance imaging : JMRI.

[4]  M Weiger,et al.  Motion‐adapted gating based on k‐space weighting for reduction of respiratory motion artifacts , 1997, Magnetic resonance in medicine.

[5]  J Keegan,et al.  MR navigator‐echo monitoring of temporal changes in diaphragm position: Implications for MR coronary angiography , 1997, Journal of magnetic resonance imaging : JMRI.

[6]  F R Gutierrez,et al.  Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. , 1996, Radiology.

[7]  S. Riederer,et al.  Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. , 1996, Radiology.

[8]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[9]  E M Haacke,et al.  MRI of Coronary Arteries: 2D Breath‐Hold vs 3D Respiratory‐Gated Acquisition , 1995, Journal of computer assisted tomography.

[10]  Todd S. Sachs,et al.  Real‐time motion detection in spiral MRI using navigators , 1994, Magnetic resonance in medicine.

[11]  Richard L. Ehman,et al.  A monitoring, feedback, and triggering system for reproducible breath‐hold MR imaging , 1993, Magnetic resonance in medicine.

[12]  E M Haacke,et al.  Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. , 1993, Radiology.