Design and development of a fully 3D dedicated x-ray computed mammotomography system

Our effort to implement a volumetric x-ray computed mammotomography (CmT) system dedicated to imaging breast disease comprises: demonstrated development of a quasi-monochromatic x-ray beam providing minimal dose and other optimal imaging figures of merit; new development of a compact, variable field-of-view, fully-3D acquisition gantry with a digital flat-panel detector facilitating more nearly complete sampling of frequency space and the physical breast volume; incorporation of iterative ordered-subsets transmission (OSTR) image reconstruction allowing modeling of the system matrix. Here, we describe the prototype 3D gantry and demonstrate initial system performance. Data collected on the prototype gantry demonstrate the feasibility of using OSTR with realistic reconstruction times. The gantry consists of a rotating W-anode x-ray tube using ultra-thick K-edge filtration, and an ~20x25cm2 digital flat-panel detector located at <60cm SID. This source/detector combination can be shifted laterally changing the location of the central ray relative to the system center-of-rotation, hence changing the effective imaging field-of-view, and is mounted on a goniometric cradle allowing <50° polar tilt, then on a 360° azimuthal rotation stage. Combined, these stages provide for positioning flexibility in a banded region about a sphere, facilitating simple circle-plus-arc-like trajectories, as well as considerably more complex 3D trajectories. Complex orbits are necessary to avoid physical hindrances from the patient while acquiring the largest imaging volume of the breast. The system capabilities are demonstrated with fully-3D reconstructed images of geometric sampling and resolution phantoms, a fabricated breast phantom containing internal features of interest, and a cadaveric breast specimen. This compact prototype provides flexibility in dedicated, fully-3D CmT imaging of healthy and diseased breasts.

[1]  James E. Bowsher,et al.  Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector , 2005, IEEE Transactions on Medical Imaging.

[2]  J. Boone,et al.  Dedicated breast CT: radiation dose and image quality evaluation. , 2001, Radiology.

[3]  Ehsan Samei,et al.  Optimizing beam quality for x-ray computed mammotomography , 2003, SPIE Medical Imaging.

[4]  Ronald J. Jaszczak,et al.  A 3D gantry single photon emission tomograph with hemispherical coverage for dedicated breast imaging , 2003 .

[5]  Stephen J. Glick,et al.  Computer simulation of CT mammography using a flat-panel imager , 2003, SPIE Medical Imaging.

[6]  Ehsan Samei,et al.  Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography. , 2004, Medical physics.

[7]  Ruola Ning,et al.  Cone-beam volume CT mammographic imaging: feasibility study , 2001, SPIE Medical Imaging.

[8]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[9]  T R Nelson,et al.  A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography. , 2004, Medical physics.

[10]  E. Samei,et al.  Initial study of quasi-monochromatic X-ray beam performance for X-ray computed mammotomography , 2003, IEEE Transactions on Nuclear Science.

[11]  Ronald J. Jaszczak,et al.  Transmission imaging with a compact gamma camera: initial results for mammotomography , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[12]  Ronald J. Jaszczak,et al.  Implementation and initial characterization of acquisition orbits with a dedicated emission mammotomograph , 2003 .

[13]  Martin P. Tornai,et al.  Anthropomorphic breast phantoms for preclinical imaging evaluation with transmission or emission imaging , 2005, SPIE Medical Imaging.

[14]  Martin P. Tornai,et al.  Investigation of cone-beam acquisitions implemented using a novel dedicated mammotomography system with unique arbitrary orbit capability (Honorable Mention Poster Award) , 2005, SPIE Medical Imaging.

[15]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .