2dx_automator: implementation of a semiautomatic high-throughput high-resolution cryo-electron crystallography pipeline.

The introduction of direct electron detectors (DED) to cryo-electron microscopy has tremendously increased the signal-to-noise ratio (SNR) and quality of the recorded images. We discuss the optimal use of DEDs for cryo-electron crystallography, introduce a new automatic image processing pipeline, and demonstrate the vast improvement in the resolution achieved by the use of both together, especially for highly tilted samples. The new processing pipeline (now included in the software package 2dx) exploits the high SNR and frame readout frequency of DEDs to automatically correct for beam-induced sample movement, and reliably processes individual crystal images without human interaction as data are being acquired. A new graphical user interface (GUI) condenses all information required for quality assessment in one window, allowing the imaging conditions to be verified and adjusted during the data collection session. With this new pipeline an automatically generated unit cell projection map of each recorded 2D crystal is available less than 5 min after the image was recorded. The entire processing procedure yielded a three-dimensional reconstruction of the 2D-crystallized ion-channel membrane protein MloK1 with a much-improved resolution of 5Å in-plane and 7Å in the z-direction, within 2 days of data acquisition and simultaneous processing. The results obtained are superior to those delivered by conventional photographic film-based methodology of the same sample, and demonstrate the importance of drift-correction.

[1]  Henning Stahlberg,et al.  Merging of image data in electron crystallography. , 2013, Methods in molecular biology.

[2]  Henning Stahlberg,et al.  Ligand-induced structural changes in the cyclic nucleotide-modulated potassium channel MloK1 , 2014, Nature Communications.

[3]  David A Agard,et al.  Influence of electron dose rate on electron counting images recorded with the K2 camera. , 2013, Journal of structural biology.

[4]  Xiangyan Zeng,et al.  2dx--user-friendly image processing for 2D crystals. , 2007, Journal of structural biology.

[5]  A. Cheng,et al.  Movies of ice-embedded particles enhance resolution in electron cryo-microscopy. , 2012, Structure.

[6]  Xiangyan Zeng,et al.  Automatic lattice determination for two-dimensional crystal images. , 2007, Journal of structural biology.

[7]  D. Agard,et al.  Electron counting and beam-induced motion correction enable near atomic resolution single particle cryoEM , 2013, Nature Methods.

[8]  A. Cheng,et al.  Beam-induced motion of vitrified specimen on holey carbon film. , 2012, Journal of structural biology.

[9]  J. Lepault,et al.  Structure of purple membrane from halobacterium halobium: recording, measurement and evaluation of electron micrographs at 3.5 Å resolution , 1986 .

[10]  Xiangyan Zeng,et al.  2dx_merge: data management and merging for 2D crystal images. , 2007, Journal of structural biology.

[11]  Anchi Cheng,et al.  Initial evaluation of a direct detection device detector for single particle cryo-electron microscopy. , 2011, Journal of structural biology.

[12]  N. Grigorieff,et al.  Accurate determination of local defocus and specimen tilt in electron microscopy. , 2003, Journal of structural biology.

[13]  N. Grigorieff,et al.  Quantitative characterization of electron detectors for transmission electron microscopy. , 2013, Journal of structural biology.

[14]  W. Chiu,et al.  Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency. , 2012, Journal of structural biology.

[15]  Xiangyan Zeng,et al.  Image processing of 2D crystal images. , 2013, Methods in molecular biology.

[16]  Xiangyan Zeng,et al.  Automation of image processing in electron crystallography. , 2013, Methods in molecular biology.

[17]  Sebastian Scherer,et al.  Single particle 3D reconstruction for 2D crystal images of membrane proteins. , 2014, Journal of structural biology.

[18]  R Henderson,et al.  Images of paraffin monolayer crystals with perfect contrast: minimization of beam-induced specimen motion. , 2011, Ultramicroscopy.

[19]  John E. Johnson,et al.  Maximizing the potential of electron cryomicroscopy data collected using direct detectors. , 2013, Journal of structural biology.

[20]  D. Julius,et al.  Structure of the TRPV1 ion channel determined by electron cryo-microscopy , 2013, Nature.

[21]  Pawel A Penczek,et al.  CTER-rapid estimation of CTF parameters with error assessment. , 2014, Ultramicroscopy.

[22]  R. Henderson,et al.  Detective quantum efficiency of electron area detectors in electron microscopy , 2009, Ultramicroscopy.