Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform

In order to improve hybrid and electrical vehicles functional safety and to avoid sudden failures, it is important to develop reliable and robust on-board diagnostics (OBD). This paper discusses the stator incipient fault diagnosis and monitoring of a permanent magnet synchronous motor for hybrid and electrical vehicles. Incipient stator fault appears as intermittent interturn faults. Studying this phenomenon had shown that it generates specific distortions in the statoric currents as well as in the reference voltages. The fault monitoring method is based on the identification of these specific distortions and on the localization of the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.

[1]  J. Penman,et al.  Detection and location of interturn short circuits in the stator windings of operating motors , 1994 .

[2]  J. Rafiee,et al.  A novel technique for selecting mother wavelet function using an intelligent fault diagnosis system , 2009, Expert Syst. Appl..

[3]  Narayan C. Kar,et al.  Current Injection-Based Online Parameter and VSI Nonlinearity Estimation for PMSM Drives Using Current and Voltage DC Components , 2016, IEEE Transactions on Transportation Electrification.

[4]  Najla Haje Obeid,et al.  Model dynamique et signature du défaut inter-spires intermittent dans les têtes de bobines d'une MSAP , 2016 .

[5]  T. R. Gopalakrishnan Nair,et al.  Adaptive wavelet based identification and extraction of PQRST combination in randomly stretching ECG sequence , 2013, 2013 IEEE China Summit and International Conference on Signal and Information Processing.

[6]  Stéphane Caux,et al.  Kalman-Filter-Based Indicator for Online Interturn Short Circuits Detection in Permanent-Magnet Synchronous Generators , 2015, IEEE Transactions on Industrial Electronics.

[7]  Raghuveer M. Rao,et al.  Algorithms for designing wavelets to match a specified signal , 2000, IEEE Trans. Signal Process..

[8]  Hui Lin,et al.  Inter-turn short circuit fault diagnosis for PMSM based on complex gauss wavelet , 2007, 2007 International Conference on Wavelet Analysis and Pattern Recognition.

[9]  Bilal Gumus,et al.  A new approach to detect stator fault in permanent magnet synchronous motors , 2015, 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED).

[10]  P. Purkait,et al.  Monitoring of inter-turn insulation failure in induction motor using advanced signal and data processing tools , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  N. Takorabet,et al.  Fault Analysis and Parameter Identification of Permanent-Magnet Motors by the Finite-Element Method , 2009, IEEE Transactions on Magnetics.

[12]  M. R. Bissonnette End-winding vibration monitoring and interpretation , 2012, 2012 IEEE International Symposium on Electrical Insulation.

[13]  Antero Arkkio,et al.  End-Winding Vibrations Caused by Steady-State Magnetic Forces in an Induction Machine , 2010, IEEE Transactions on Magnetics.

[14]  Michael Unser,et al.  Construction of biorthogonal wavelets starting from any two multiresolutions , 1998, IEEE Trans. Signal Process..

[15]  Shumei Cui,et al.  Interturn Fault Diagnosis Strategy for Interior Permanent-Magnet Synchronous Motor of Electric Vehicles Based on Digital Signal Processor , 2016, IEEE Transactions on Industrial Electronics.

[16]  Giorgio Rizzoni,et al.  Fault Diagnosis for Electric Drive Systems of Electrified Vehicles Based on Structural Analysis , 2017, IEEE Transactions on Vehicular Technology.

[17]  Simone Ferrari,et al.  Two Design Procedures for PM Synchronous Machines for Electric Powertrains , 2017, IEEE Transactions on Transportation Electrification.

[18]  Shiv Dutt Joshi,et al.  A new approach for estimation of statistically matched wavelet , 2005, IEEE Transactions on Signal Processing.

[19]  Najla Haje Obeid,et al.  Modeling and Diagnostic of Incipient Interturn Faults for a Three-Phase Permanent Magnet Synchronous Motor , 2014, IEEE Transactions on Industry Applications.

[20]  Thomas G. Habetler,et al.  A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems , 2008, IEEE Transactions on Industrial Electronics.

[21]  B. Nahid-Mobarakeh,et al.  Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM , 2013, IEEE Transactions on Power Electronics.

[22]  Thomas G. Habetler,et al.  Using Only the DC Current Information to Detect Stator Turn Faults in Automotive Claw-Pole Generators , 2013, IEEE Transactions on Industrial Electronics.

[23]  B. Nahid-Mobarakeh,et al.  Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis , 2011, IEEE Transactions on Industry Applications.

[24]  Ki-Chan Kim,et al.  Analysis of electromagnetic force distribution on end winding for motor reliance , 2005, INTERMAG Asia 2005. Digests of the IEEE International Magnetics Conference, 2005..