Two-dimensional ultrasound receive array using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging

A 2-D optical ultrasound receive array has been investigated. The transduction mechanism is based upon the detection of acoustically induced changes in the optical thickness of a thin polymer film acting as a Fabry-Perot sensing interferometer (FPI). By illuminating the sensor with a large-area laser beam and mechanically scanning a photodiode across the reflected output beam, while using a novel angle-tuned phase bias control system to optimally set the FPI working point, a notional 2-D ultrasound array was synthesized. To demonstrate the concept, 1-D and 2-D ultrasound field distributions produced by planar 3.5-MHz and focused 5-MHz PZT ultrasound transducers were mapped. The system was also evaluated by performing transmission ultrasound imaging of a spatially calibrated target. The "array" aperture, defined by the dimensions of the incident optical field, was elliptical, of dimensions 16 /spl times/ 12 mm and spatially sampled in steps of 0.1 mm or 0.2 mm. Element sizes, defined by the photodiode aperture, of 0.8, 0.4, and 0.2 mm were variously used for these experiments. Two types of sensor were evaluated. One was a discrete 75-/spl mu/m-thick polyethylene terephthalate FPI bonded to a polymer backing stub which had a wideband peak noise-equivalent pressure of 6.5 kPa and an acoustic bandwidth 12 MHz. The other was a 40-/spl mu/m Parylene film FPI which was directly vacuum-deposited onto a glass backing stub and had an NEP of 8 kPa and an acoustic bandwidth of 17.5 MHz. It is considered that this approach offers an alternative to piezoelectric ultrasound arrays for transducer field characterization, transmission medical and industrial ultrasound imaging, biomedical photoacoustic imaging, and ultrasonic nondestructive testing.

[1]  P C Beard Interrogation of free-space Fabry–Perot sensing interferometers by angle tuning , 2003 .

[2]  Paul C. Beard,et al.  Characterisation of a polmer film optical fibre hydropone for the measurement of ultrasound fields for use in the range 1-20MHz: a comparsion with PVDF needle and membrane hydrophones , 2000 .

[3]  P. Beard,et al.  Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  M. O'Donnell,et al.  High frequency optoacoustic arrays using etalon detection , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Paul C. Beard,et al.  A 2D optical ultrasound array using a polymer film sensing interferometer , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[6]  Paul C. Beard Photoacoustic imaging of blood vessel equivalent phantoms , 2002, SPIE BiOS.

[7]  Edward Z. Zhang,et al.  Fabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation , 2004 .

[8]  Martin Frenz,et al.  Optical method for two-dimensional ultrasonic detection , 1999 .

[9]  F. Perennes,et al.  Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  J. Holden,et al.  Multiple-Beam Interferometry: Intensity Distribution in the Reflected System , 1949 .

[11]  M. O'Donnell,et al.  High frequency ultrasound imaging with optical arrays , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Paul C. Beard,et al.  Ultrahigh-sensitivity wideband Fabry-Perot ultrasound sensors as an alternative to piezoelectric PVDF transducers for biomedical photoacoustic detection , 2004, SPIE BiOS.

[13]  K. P. Köstli,et al.  Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response. , 2003, Applied optics.

[14]  A. E. Ashby,et al.  OPUS: an optically parallel ultrasound sensor , 2000, BiOS.

[15]  Kentaro Nakamura,et al.  Pressure Sensitivity of a Fiber-Optic Microprobe for High-Frequency Ultrasonic Field , 1999 .

[16]  V Wilkens,et al.  Optical multilayer detection array for fast ultrasonic field mapping. , 1999, Optics letters.

[17]  P C Beard,et al.  Optical fiber photoacoustic-photothermal probe. , 1998, Optics letters.