Failure Probability Analysis for Emergency Disconnect of Deepwater Drilling Riser Using Bayesian Network

Drilling risers are the crucial connection of subsea wellhead and floating drilling vessel. Emergency disconnect (ED) is the most important protective measure to secure the risers and wellhead under extreme conditions. This paper proposes a methodology for failure probability analysis of ED operations using Bayesian network (BN). The risk factors associated with ED operations and the potential consequences of ED failure were investigated. A systematic ED failure and consequence model was established through fault tree and event sequence diagram (FT-ESD) analyses and, then the FT-ESD model was mapped into BN. Critical root causes of ED failure were inferred by probability updating, and the most probable accident evolution paths as well as the most probable consequence evolution paths of ED failure were figured out. Moreover, the probability adaptation was performed at regular intervals to estimate the probabilities of ED failure, and the occurrence probabilities of consequences caused by ED failure. The practical application of the developed model was demonstrated through a case study. The results showed that the probability variations of ED failure and corresponding consequences depended on the states of critical basic events (BEs). Eventually, some active measures in drilling riser system design, drilling operation, ED test, and operation were proposed for mitigating the probability of ED failure.

[1]  Brian Veitch,et al.  Methodology for computer aided fuzzy fault tree analysis , 2009 .

[2]  Yonghong Liu,et al.  Using Bayesian networks in reliability evaluation for subsea blowout preventer control system , 2012, Reliab. Eng. Syst. Saf..

[3]  Alan Whooley,et al.  Ensuring Safe Riser Emergency Disconnect in Harsh Environments: Experience and Design Requirements , 2013 .

[4]  Luigi Portinale,et al.  Improving the analysis of dependable systems by mapping fault trees into Bayesian networks , 2001, Reliab. Eng. Syst. Saf..

[5]  Liu Yong-hon Reliability research on subsea wellhead connector of blowout preventer stack , 2013 .

[6]  Marvin Rausand,et al.  Risk Assessment Process , 2013 .

[7]  Mohit Kumar,et al.  The weakest t-norm based intuitionistic fuzzy fault-tree analysis to evaluate system reliability. , 2012, ISA transactions.

[8]  James N. Brekke Key Elements in Ultra-Deep Water Drilling Riser Management , 2001 .

[9]  Yonghong Liu,et al.  Application of Bayesian Networks in Quantitative Risk Assessment of Subsea Blowout Preventer Operations , 2013, Risk analysis : an official publication of the Society for Risk Analysis.

[10]  Carol Smidts,et al.  The Event Sequence Diagram framework for dynamic Probabilistic Risk Assessment , 1999 .

[11]  Kui Xu,et al.  Fuzzy fault tree assessment based on improved AHP for fire and explosion accidents for steel oil storage tanks. , 2014, Journal of hazardous materials.

[12]  Zaili Yang,et al.  Fuzzy risk assessment of oil and gas offshore wells , 2011 .

[13]  Guoming Chen,et al.  Optimal maintenance strategy for corroded subsea pipelines , 2017 .

[14]  Hongwei Zhu,et al.  Quantitative risk analysis on leakage failure of submarine oil and gas pipelines using Bayesian network , 2016 .

[15]  Muhammad Usman,et al.  A modified CREAM to human reliability quantification in marine engineering , 2013 .

[16]  Rouzbeh Abbassi,et al.  Corrosion induced failure analysis of subsea pipelines , 2017, Reliab. Eng. Syst. Saf..

[17]  Metin Celik,et al.  An extension to Fuzzy Fault Tree Analysis (FFTA) application in petrochemical process industry , 2015 .

[18]  Faisal Khan,et al.  Quantitative risk analysis of offshore drilling operations: A Bayesian approach , 2013 .

[19]  Nima Khakzad,et al.  Application of event sequence diagram to evaluate emergency response actions during fire-induced domino effects , 2016, Reliab. Eng. Syst. Saf..

[20]  William F. Puccio,et al.  Riser recoil during unscheduled Lower Marine Riser Package disconnects , 1998 .

[21]  Jieshuo Xie,et al.  An Overview of Internal Solitary Waves in the South China Sea , 2012, Surveys in Geophysics.

[22]  Frank Grealish,et al.  Soft Hangoff Method for Drilling Risers in Ultra Deepwater , 2001 .

[23]  Lei Zhang,et al.  Dynamic accident modeling for high-sulfur natural gas gathering station , 2014 .

[24]  Michael Lane,et al.  Recent Developments in Drilling Riser Disconnect and Recoil Analysis for Deepwater Applications , 2009 .

[25]  Vikram Garaniya,et al.  Risk analysis of deepwater drilling operations using Bayesian network , 2015 .

[26]  Warren D. Seider,et al.  Plant-specific dynamic failure assessment using Bayesian theory , 2006 .

[27]  Pengcheng Luo,et al.  System risk evolution analysis and risk critical event identification based on event sequence diagram , 2013, Reliab. Eng. Syst. Saf..

[28]  Marvin Rausand,et al.  Risk Assessment: Theory, Methods, and Applications , 2011 .

[29]  Billy D. Ambrose,et al.  Application of a Deepwater Riser Risk Analysis to Drilling Operations and Riser Design , 2001 .

[30]  Stephen Butt,et al.  Safety and risk analysis of managed pressure drilling operation using Bayesian network , 2015 .

[31]  Paul Stanton,et al.  New Revision of Drilling Riser Recommended Practice (API RP 16Q) , 2002 .

[32]  Jon Espen Skogdalen,et al.  Quantitative risk analysis offshore - Human and organizational factors , 2011, Reliab. Eng. Syst. Saf..

[33]  Min Xie,et al.  A Real-Time Fault Diagnosis Methodology of Complex Systems Using Object-Oriented Bayesian Networks , 2016, Bayesian Networks in Fault Diagnosis.

[34]  Faisal Khan,et al.  Dynamic safety analysis of process systems by mapping bow-tie into Bayesian network , 2013 .

[35]  Liangbin Xu,et al.  Envelopes for connected operation of the deepwater drilling riser , 2012 .

[36]  Arild Grønevik Simulation of drilling riser disconnection - Recoil analysis , 2013 .

[37]  Emre Akyuz,et al.  Utilisation of Fuzzy Fault Tree Analysis (FFTA) for quantified risk analysis of leakage in abandoned oil and natural-gas wells , 2015 .

[38]  Zhen Chen,et al.  Risk assessment of an oxygen-enhanced combustor using a structural model based on the FMEA and fuzzy fault tree , 2014 .

[39]  Qian Fan,et al.  Multi-source information fusion based fault diagnosis of ground-source heat pump using Bayesian network , 2014 .