A parallel tracking method for acoustic radiation force impulse imaging

Radiation force-based techniques have been developed by several groups for imaging the mechanical properties of tissue. Acoustic radiation force impulse (ARFI) imaging is one such method that uses commercially available scanners to generate localized radiation forces in tissue. The response of the tissue to the radiation force is determined using conventional B-mode imaging pulses to track micron-scale displacements in tissue. Current research in ARFI imaging is focused on producing real-time images of tissue displacements arid related mechanical properties. Obstacles to producing a real-time ARFl imaging modality include data acquisition, processing power, data transfer rates, heating of the transducer, and patient safety concerns. We propose a parallel receive beamforming technique to reduce transducer heating and patient acoustic exposure, and to facilitate data acquisition for real-time ARFI imaging. Custom beam sequencing was used with a commercially available scanner to track tissue displacements with parallel-receive beamforming in tissue-mimicking phantoms. Using simulations, the effects of material properties on parallel tracking are observed. Transducer and tissue heating for parallel tracking are compared to standard ARFI beam sequencing. The effects of tracking beam position and size of the tracked region are also discussed in relation to the size and temporal response of the region of applied force, and the impact on ARFI image contrast arid signal-to-noise ratio are quantified

[1]  W. O’Brien,et al.  Volumetric blood flow via time-domain correlation: experimental verification , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[3]  D. G. Simpson,et al.  Evaluation of unscanned-mode soft-tissue thermal index for rectangular sources and proposed new indices. , 2004, Ultrasound in medicine & biology.

[4]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[5]  R. Bouchard,et al.  A finite-element method model of soft tissue response to impulsive acoustic radiation force , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  T. Loupas,et al.  Experimental evaluation of velocity and power estimation for ultrasound blood flow imaging, by means of a two-dimensional autocorrelation approach , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  J F Greenleaf,et al.  Vibro-acoustography: an imaging modality based on ultrasound-stimulated acoustic emission. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[8]  Gregg E. Trahey,et al.  Acoustic radiation force impulse imaging of in vivo breast masses , 2004 .

[9]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[10]  M. Fink,et al.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  M. Bilgen,et al.  Error analysis in acoustic elastography. II. Strain estimation and SNR analysis. , 1997, The Journal of the Acoustical Society of America.

[12]  W F Walker,et al.  A method of imaging viscoelastic parameters with acoustic radiation force. , 2000, Physics in medicine and biology.

[13]  K. Nightingale,et al.  On the thermal effects associated with radiation force imaging of soft tissue , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  B. Friemel,et al.  Speckle decorrelation due to two-dimensional flow gradients , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.

[16]  G. Trahey,et al.  Estimates of echo correlation and measurement bias in acoustic radiation force impulse imaging , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Mark Palmeri,et al.  Analysis of contrast in images generated with transient acoustic radiation force. , 2006, Ultrasound in medicine & biology.

[18]  R. Phillips Guidance for Industry and FDA Staff Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers , 2008 .

[19]  G.E. Trahey,et al.  Rapid tracking of small displacements with ultrasound , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  Paul L. Carson,et al.  Exposure criteria for medical diagnostic ultrasound: I. Criteria based on thermal mechanisms , 1992 .

[21]  G. Trahey,et al.  Ultrasonic tracking of acoustic radiation force-induced displacements in homogeneous media , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Gregg Trahey,et al.  Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. , 2002, Ultrasound in medicine & biology.

[23]  I Céspedes,et al.  Fundamental mechanical limitations on the visualization of elasticity contrast in elastography. , 1995, Ultrasound in medicine & biology.

[24]  C L de Korte,et al.  Echo decorrelation from displacement gradients in elasticity and velocity estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  G. Trahey,et al.  Dynamic mechanical response of elastic spherical inclusions to impulsive acoustic radiation force excitation , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.