Double-SOI Wafer-Bonded CMUTs With Improved Electrical Safety and Minimal Roughness of Dielectric and Electrode Surfaces

Despite myriad potential advantages over piezoelectric ultrasound transducers, capacitive micromachined ultrasound transducers (CMUTs) have not yet seen widespread commercial implementation. The possible reasons for this may include key issues of the following: (1) long-term device reliability and (2) electrical safety issues associated with relatively high voltage electrodes on device surfaces which could present an electrical safety hazard to patients. A CMUT design presented here may mitigate some of these problems. Dielectric charging is one phenomenon which can lead to unpredictable performance and device failure. Using a previously published 1-D model of dielectric charging, we link minimal dielectric surface roughness with minimal dielectric charging. Previous studies of Fowler-Nordheim tunneling suggest that minimal-surface-roughness electrodes could lead to minimal transdielectric currents (and, hence, slower dielectric charging rates). These principles guided our device architecture, leading us to engineer near atomically smooth electrodes and dielectric surfaces to minimize dielectric charging. To provide maximum electrical safety to future patients, CMUT devices were engineered with the top membrane serving as a ground electrode. While multiple CMUT elements have not been individually addressable in most such designs to our knowledge, we introduce a fabrication method involving two silicon-on-insulator wafers with a step to define individually addressable electrodes. Our devices are modeled using a finite-element package. Measured deflections show excellent agreement with modeled performance. We test for charge effects by studying deflection hysteresis during snapdown and snapback cycles in the limit of long snapdown durations to simulate maximal-dielectric-charging conditions. Devices were also tested in long-term actuation tests and subjected to more than 3 × 1010 cycles without failure.

[1]  Edward Hæggström,et al.  Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology , 2003 .

[2]  R. Fowler,et al.  Electron Emission in Intense Electric Fields , 1928 .

[3]  M. Lenzlinger,et al.  Fowler‐Nordheim Tunneling into Thermally Grown SiO2 , 1969 .

[4]  Mario Kupnik,et al.  Low temperature process for CMUT fabrication with wafer bonding technique , 2010, 2010 IEEE International Ultrasonics Symposium.

[5]  D. T. Yeh,et al.  Experimental characterization of collapse-mode CMUT operation , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Ching-Hsiang Cheng,et al.  Comparison of conventional and collapsed region operation of capacitive micromachined ultrasonic transducers , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[7]  Walied A. Moussa,et al.  Finite element modeling of a capacitive micromachined ultrasonic transducer , 2003, Proceedings International Conference on MEMS, NANO and Smart Systems.

[8]  Andreas C. Cangellaris,et al.  A compact model for dielectric charging in RF MEMS capacitive switches , 2009 .

[9]  O. Oralkan,et al.  Next-gen ultrasound , 2009, IEEE Spectrum.

[10]  B. S. Gossling,et al.  Further studies in the emission of electrons from cold metals , 1929 .

[11]  Mario Kupnik,et al.  CMUT fabrication based on a thick buried oxide layer , 2010, 2010 IEEE International Ultrasonics Symposium.

[12]  O. Oralkan,et al.  Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  J. Yeow,et al.  Fabricating capacitive micromachined ultrasonic transducers with a novel silicon-nitride-Based wafer bonding process , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  B.T. Khuri-Yakub,et al.  A new regime for operating capacitive micromachined ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Suresh V. Garimella,et al.  Simulation of ion generation and breakdown in atmospheric air , 2004 .

[16]  Robert Puers,et al.  A comprehensive model to predict the charging and reliability of capacitive RF MEMS switches , 2004 .

[17]  Andreas C. Cangellaris,et al.  Modeling of dielectric charging in RF MEMS capacitive switches , 2007 .

[18]  Dimitrios Peroulis,et al.  Direct measurement of field emission current in E-static MEMS structures , 2011, 2011 IEEE 24th International Conference on Micro Electro Mechanical Systems.

[19]  Roger J. Zemp,et al.  CMUTs with improved electrical safety & minimal dielectric surface charging , 2010, 2010 IEEE International Ultrasonics Symposium.

[20]  B. Khuri-Yakub,et al.  Surface micromachined capacitive ultrasonic transducers , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  Xuefeng Zhuang,et al.  Evaluation of wafer bonded CMUTs with rectangular membranes featuring high fill factor , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Xuefeng Zhuang,et al.  Capacitive micromachined ultrasonic transducers (CMUTs) with isolation posts , 2004, IEEE Ultrasonics Symposium, 2004.

[23]  G. G. Yaralioglu,et al.  Biocompatible coatings for CMUTs in a harsh, aqueous environment , 2007 .

[24]  O. Oralkan,et al.  Capacitive micromachined ultrasonic transducer design for high power transmission , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.