Using a sensitive optical system to analyze gases dissolved in samples extracted from transformer oil

A sensitive optical system which can be used to measure accurately the concentrations of fault gases dissolved in samples extracted from transformer oil is described, and some test results are presented.

[1]  Ivanka Höhlein-Atanasova,et al.  Carbon oxides in the interpretation of dissolved gas analysis in transformers and tap changers , 2010, IEEE Electrical Insulation Magazine.

[2]  Michel Duval,et al.  A review of faults detectable by gas-in-oil analysis in transformers , 2002 .

[3]  I. White,et al.  Trace detection of C2H2 in ambient air using continuous wave cavity ring-down spectroscopy combined with sample pre-concentration , 2008 .

[4]  L. Hollberg,et al.  Frequency stabilization of semiconductor lasers by resonant optical feedback. , 1987, Optics letters.

[5]  Raj Aggarwal,et al.  Analysis of power transformer dissolved gas data using the self-organizing map , 2003 .

[6]  M. Carras,et al.  Optical-feedback cavity-enhanced absorption spectroscopy with a quantum cascade laser. , 2010, Optics letters.

[7]  F. Capasso,et al.  New frontiers in quantum cascade lasers and applications , 2000, IEEE Journal of Selected Topics in Quantum Electronics.

[8]  Tapan Kumar Saha,et al.  Review of modern diagnostic techniques for assessing insulation condition in aged transformers , 2003 .

[9]  D. Romanini,et al.  CW cavity ring down spectroscopy , 1997 .

[10]  S. J. Ferrito A comparative study of dissolved gas analysis techniques: the vacuum extraction method versus the direct injection method , 1990 .

[11]  Q. Henry Wu,et al.  Power Transformer Fault Classification Based on Dissolved Gas Analysis by Implementing Bootstrap and Genetic Programming , 2009, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[12]  P. Werle,et al.  Near- and mid-infrared laser-optical sensors for gas analysis , 2002 .

[13]  V. M. Devi,et al.  Q branches of the nu(7) fundamental of ethane (C(2)H(6)): integrated intensity measurements for atmospheric measurement applications. , 1986, Applied optics.

[14]  Federico Capasso,et al.  Single-mode, tunable distributed-feedback and multiple-wavelength quantum cascade lasers , 2002 .

[15]  Emiliano Sisinni,et al.  Fast, Versatile, and Low-Cost Interface Circuit for Electrochemical and Resistive Gas Sensor , 2014, IEEE Sensors Journal.

[16]  J. J. Kelly Transformer Fault Diagnosis by Dissolved-Gas Analysis , 1980, IEEE Transactions on Industry Applications.

[17]  V.G. Arakelian,et al.  The long way to the automatic chromatographic analysis of gases dissolved in insulating oil , 2004, IEEE Electrical Insulation Magazine.

[18]  K. Suganuma,et al.  Development of oil-dissolved hydrogen gas detector for diagnosis of transformers , 1990 .

[19]  W.H. Tang,et al.  A Probabilistic Classifier for Transformer Dissolved Gas Analysis With a Particle Swarm Optimizer , 2008, IEEE Transactions on Power Delivery.

[20]  Thierry Gonthiez,et al.  Multispecies breath analysis faster than a single respiratory cycle by optical-feedback cavity-enhanced absorption spectroscopy. , 2009, Journal of biomedical optics.

[21]  L. L. Lai,et al.  A fuzzy dissolved gas analysis method for the diagnosis of multiple incipient faults in a transformer , 2000 .

[22]  Z. Balogh,et al.  Modelling, simulation and monitoring the use of LabVIEW , 2012, 2012 6th International Conference on Application of Information and Communication Technologies (AICT).

[23]  Selwyn Palmer,et al.  Detection of faults in new and old transformers by dissolved-gas analysis , 1988 .

[24]  A. Fried,et al.  Development of a tunable mid-IR difference frequency laser source for highly sensitive airborne trace gas detection , 2002, Applied physics. B, Lasers and optics.

[25]  L. Nähle,et al.  Continuous wave, distributed feedback diode laser based sensor for trace-gas detection of ethane , 2012 .

[26]  Michel Duval,et al.  New techniques for dissolved gas-in-oil analysis , 2003 .

[27]  Yabai He,et al.  Ringdown and cavity-enhanced absorption spectroscopy using a continuous-wave tunable diode laser and a rapidly swept optical cavity , 2000 .

[28]  Frank K. Tittel,et al.  Compact QEPAS sensor for trace methane and ammonia detection in impure hydrogen , 2012 .

[29]  G. Berden,et al.  Cavity enhanced absorption spectroscopy in the 10 μm region using a waveguide CO2 laser , 2001 .

[30]  Wei Huang,et al.  Portable remote sensor of methane leakage using near-IR diode laser , 2005, Other Conferences.

[31]  I. Cotton,et al.  Dissolved gas analysis of alternative fluids for power transformers , 2007, IEEE Electrical Insulation Magazine.

[32]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[33]  P. Zylka,et al.  Electrochemical gas sensors can supplement chromatography-based DGA , 2005 .

[34]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[35]  A. Orr-Ewing,et al.  A quantum cascade laser-based optical feedback cavity-enhanced absorption spectrometer for the simultaneous measurement of CH4 and N2O in air , 2011 .

[36]  B. Alawieh,et al.  Real-time control of free-standing cart-mounted inverted pendulum using LabVIEW RT , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[37]  Jintao Li,et al.  Sliding Average Allan Variance for Inertial Sensor Stochastic Error Analysis , 2013, IEEE Transactions on Instrumentation and Measurement.