Fluorescence Rejection in Resonance Raman Spectroscopy Using a Picosecond-Gated Intensified Charge-Coupled Device Camera

A Raman instrument was assembled and tested that rejects typically 98–99% of background fluorescence. Use is made of short (picosecond) laser pulses and time-gated detection in order to record the Raman signals during the pulse while blocking most of the fluorescence. Our approach uses an ultrafast-gated intensified charge-coupled device (ICCD) camera as a simple and straightforward alternative to ps Kerr gating. The fluorescence rejection efficiency depends mainly on the fluorescence lifetime and on the closing speed of the gate (which is about 80 ps in our setup). A formula to calculate this rejection factor is presented. The gated intensifier can be operated at 80 MHz, so high repetition rates and low pulse energies can be used, thus minimizing photodegradation. For excitation we use a frequency-tripled or -doubled Ti: sapphire laser with a pulse width of 3 ps; it should not be shorter in view of the required spectral resolution. Other critical aspects tested include intensifier efficiency as a function of gate width, uniformity of the gate pulse across the spectrum, and spectral resolution in comparison with ungated detection. The total instrumental resolution is 7 cm−1 in the blue and 15 cm−1 in the ultraviolet (UV) region. The setup allows one to use resonance Raman spectroscopy (RRS) for extra sensitivity and selectivity, even in the case of strong background fluorescence. Excitation wavelengths in the visible or UV range no longer have to be avoided. The effectiveness of this setup is demonstrated on a test system: pyrene in the presence of toluene fluorescence (λexc = 257 nm). Furthermore, good time-gated RRS spectra are shown for a strongly fluorescent flavoprotein (λexc = 405 nm). Advantages and disadvantages of this approach for RRS are discussed.

[1]  R. Jackson,et al.  Fluorescence rejection in Raman spectroscopy using a synchronously pumped, cavity-dumped dye laser and gated photon counting , 1986 .

[2]  E. Baerends,et al.  Combined theoretical and experimental deep-UV resonance raman studies of substituted pyrenes. , 2005, The journal of physical chemistry. A.

[3]  E. Liang,et al.  Surface-Enhanced Resonance Raman Spectroscopy of Flavins on Silver Nitrate-Modified Cu and Fe as Well as Cu-Zn-Pb and Fe-C-Cr-Ni Surfaces , 1994 .

[4]  Pavel Matousek,et al.  Efficient Rejection of Fluorescence from Raman Spectra Using Picosecond Kerr Gating , 1999 .

[5]  S. Bell,et al.  Quantitative Raman spectroscopy of highly fluorescent samples using pseudosecond derivatives and multivariate analysis. , 2001, Analytical chemistry.

[6]  Marco W. Fraaije,et al.  Baeyer-Villiger monooxygenases, an emerging family of flavin-dependent biocatalysts , 2003 .

[7]  A. Munro,et al.  Analysis of the structure of the flavin-binding sites of flavocytochrome P450 BM3 using surface enhanced resonance Raman scattering , 1999, European Biophysics Journal.

[8]  Dmitry Martyshkin,et al.  Effective suppression of fluorescence light in Raman measurements using ultrafast time gated charge coupled device camera , 2004 .

[9]  Hiro-o Hamaguchi,et al.  Picosecond Raman Spectroscopy Using a Streak Camera , 1993 .

[10]  I. P. Chernikevich,et al.  Surface enhanced Raman scattering investigation of protein-bound flavin adenine dinucleotide structure , 1995 .

[11]  Marco W. Fraaije,et al.  Discovery of a thermostable Baeyer–Villiger monooxygenase by genome mining , 2004, Applied Microbiology and Biotechnology.

[12]  R. W. Jackson,et al.  Fluorescence rejection in Raman spectroscopy using a gated intensified diode array detector , 1986 .

[13]  William F. Finney,et al.  Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy , 2005, Applied spectroscopy.

[14]  S. Asher,et al.  Ultraviolet resonance Raman study of the pyrene S4, S3, and S2 excited electronic states , 1988 .

[15]  T. Spiro,et al.  Normal mode analysis of lumiflavin and interpretation of resonance Raman spectra of flavoproteins. , 1981, Biochemistry.

[16]  P. Matousek,et al.  Resonance Raman spectroscopy of highly fluorescing lignin containing chemical pulps: Suppression of fluorescence with an optical Kerr gate , 2004 .

[17]  Michael J. Pelletier,et al.  Analytical Applications of Raman Spectroscopy , 1999 .

[18]  N. Vermeulen,et al.  Binding of 7-methoxy-4-(aminomethyl)-coumarin to wild-type and W128F mutant cytochrome P450 2D6 studied by time-resolved fluorescence spectroscopy. , 2006, The Biochemical journal.

[19]  Pavel Matousek,et al.  Picosecond Time-Resolved Raman Spectroscopy of Solids: Capabilities and Limitations for Fluorescence Rejection and the Influence of Diffuse Reflectance , 2001 .

[20]  R. J. Dijkstra,et al.  On-line identification method in column liquid chromatography: UV resonance Raman spectroscopy. , 2001, Analytical chemistry.

[21]  R. J. Dijkstra,et al.  Capillary electrophoresis coupled on-line with ultraviolet resonance Raman spectroscopy. , 2003, Analytical chemistry.

[22]  Richard A. Mathies,et al.  Effective Rejection of Fluorescence Interference in Raman Spectroscopy Using a Shifted Excitation Difference Technique , 1992 .