Semi-empirical formulation of multiple scattering for the Gaussian beam model of heavy charged particles stopping in tissue-like matter

Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particles in water, empirically found in measurements and detailed calculations. This fact was translated into a simple linear formula, from which the scattering power that is only inversely proportional to the residual range was derived. The simplicity enabled the analytical formulation for ions stopping in water, which was designed to be equivalent with the extended Highland model and agreed with measurements within 2% or 0.02 cm in RMS displacement. The simplicity will also improve the efficiency of numerical path integrals in the presence of heterogeneity.

[1]  N. Kanematsu Alternative scattering power for Gaussian beam model of heavy charged particles , 2008, 0806.0106.

[2]  N. Kanematsu,et al.  The grid-dose-spreading algorithm for dose distribution calculation in heavy charged particle radiotherapy. , 2007, Medical physics.

[3]  H. Yamashita,et al.  Extended collimator model for pencil-beam dose calculation in proton radiotherapy , 2006, Physics in medicine and biology.

[4]  T. Inaniwa,et al.  Spatial fragment distribution from a therapeutic pencil-like carbon beam in water , 2005, Physics in medicine and biology.

[5]  A. Brahme,et al.  Influence of multiple scattering and energy loss straggling on the absorbed dose distributions of therapeutic light ion beams: I. Analytical pencil beam model. , 2004, Physics in medicine and biology.

[6]  Nobuyuki Kanematsu,et al.  A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning. , 2003, Physics in medicine and biology.

[7]  J O Deasy,et al.  A proton dose calculation algorithm for conformal therapy simulations based on Molière's theory of lateral deflections. , 1998, Medical physics.

[8]  Nobuyuki Kanematsu,et al.  A Proton Dose Calculation Code for Treatment Planning Based on the Pencil Beam Algorithm , 1998 .

[9]  Robert J. Schneider,et al.  Multiple Coulomb scattering of 160 MeV protons , 1993 .

[10]  M. Phillips,et al.  The multiple Coulomb scattering of very heavy charged particles. , 1990, Medical physics.

[11]  Geoffrey S. Ibbott,et al.  Radiation Dosimetry: Electron Beams with Energies Between 1 and 50MeV (ICRU Report No. 35) , 1985 .

[12]  V. Highland,et al.  Some Practical Remarks on Multiple Scattering , 1975 .

[13]  A. O. Hanson,et al.  MEASUREMENT OF MULTIPLE SCATTERING OF 15.7-MEV ELECTRONS , 1951 .

[14]  Leonard Eyges,et al.  Multiple Scattering with Energy Loss , 1948 .

[15]  T. Gaisser Cosmic ray theory. , 1990 .