Investigating the Effects of Temperature on Photoplethysmography

Pulse oximetry is a commonly used technique to determine arterial oxygen saturation (SpO2) and heart rate. This method uses photoplethysmography (PPG) signals to estimate SpO2. However, pulse oximeters can be less accurate at cold temperatures. In this research, the effects of temperature on PPG signal quality was investigated for a group of 20 adult volunteers. Raw PPG data was obtained using a custom pulse oximeter (PO) system. Three tests were performed with the subject's hand maintained at baseline, cold, and warm temperatures. Analysis showed the median PPG signal RMS, as an indicator of signal-to-noise, for the warm test was 0.0289 V [IQR = 0.0262 - 0.0315 V] compared to the baseline test's 0.0174 V [IQR = 0.0104 - 0.0285 V] and the cold test's 0.0066 V [IQR = 0.0053 - 0.0106V]. This improvement of up to 4x in signal quality was associated with a closer match between the SpO2 values estimated by the PO system and a commercial pulse oximeter. Paired RMS value comparison between the three tests showed a statistically significant difference for all P-values (P < 0.004). Results indicate that warm temperatures improve PPG quality and thus pulse oximeter accuracy.

[1]  B. Engbretson,et al.  Does ambient light affect the accuracy of pulse oximetry? , 2003, Respiratory care.

[2]  O G Edholm,et al.  The effect of temperature on blood flow and deep temperature in the human forearm , 1943, The Journal of physiology.

[3]  John M. Graybeal,et al.  The Effect of Motion on Pulse Oximetry and Its Clinical Significance , 2007, Anesthesia and analgesia.

[4]  B. Lilja,et al.  The effect of local cold application on intramuscular blood flow at rest and after running. , 1985, Medicine and science in sports and exercise.

[5]  J. Severinghaus,et al.  Dark Skin Decreases the Accuracy of Pulse Oximeters at Low Oxygen Saturation: The Effects of Oximeter Probe Type and Gender , 2007, Anesthesia and analgesia.

[6]  Sara Bergstrand,et al.  Blood flow measurements at different depths using photoplethysmography and laser Doppler techniques , 2009, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[7]  K. Shelley Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate , 2007, Anesthesia and analgesia.

[8]  T. L. Rusch,et al.  Signal processing methods for pulse oximetry , 1996, Comput. Biol. Medicine.

[9]  Greg Atkinson,et al.  Influence of Cold Water Immersion on Limb and Cutaneous Blood Flow at Rest , 2011, The American journal of sports medicine.

[10]  Meir Nitzan,et al.  Pulse oximetry: fundamentals and technology update , 2014, Medical devices.

[11]  C. Hanning,et al.  Fortnightly Review: Pulse oximetry: a practical review , 1995 .

[12]  W. B. Murray,et al.  The peripheral pulse wave: Information overlooked , 1996, Journal of clinical monitoring.

[13]  Catherine O'Brien,et al.  Hypohydration effect on finger skin temperature and blood flow during cold-water finger immersion. , 2003, Journal of applied physiology.

[14]  L. Nilsson Respiration Signals from Photoplethysmography , 2013, Anesthesia and analgesia.

[15]  Roland Kadefors,et al.  A non-invasive measure of changes in blood flow in the human anterior tibial muscle , 2001, European Journal of Applied Physiology.

[16]  S. Barker,et al.  Masimo Signal Extraction Pulse Oximetry , 2004, Journal of Clinical Monitoring and Computing.

[17]  N. Artinian,et al.  Pulse oximetry in adults. , 2009, The American journal of nursing.

[18]  Kirk H. Shelley,et al.  Measuring venous oxygenation using the photoplethysmograph waveform , 2010, Journal of Clinical Monitoring and Computing.

[19]  Jonas Pettersson,et al.  Non-invasive continuous estimation of blood flow changes in human patellar bone , 2006, Medical and Biological Engineering and Computing.

[20]  Susan DeMeulenaere,et al.  Pulse Oximetry: Uses and Limitations , 2007 .

[21]  Y. Mendelson Pulse oximetry: theory and applications for noninvasive monitoring. , 1992, Clinical chemistry.

[22]  J. Dickson,et al.  Humans are Horribly Variable , 2014 .

[23]  Kirk H. Shelley,et al.  Modulation of finger photoplethysmographic traces during forced respiration: Venous blood in motion? , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  I. Macdonald,et al.  Effect of two methods of hand heating on body temperature, forearm blood flow, and deep venous oxygen saturation , 1990 .