Exposure of the Swiss population to computed tomography

BackgroundThe frequency of CT procedures has registered a significant increase over the last decade, which led at the international level to an increasing concern on the radiological risk associated with the use of CT especially in paediatrics. This work aimed at investigating the use of computed tomography in Switzerland, following the evolution of CT frequency and dose data over a decade and comparing it to data reported in other countries.MethodsThe frequency and dose data related to CT are obtained by means of a nationwide survey. National frequencies were established by projecting the collected data, using the ratio of the number of CT units belonging to the respondents to the total number of CT units in the country. The effective doses per examination were collected during an auditing campaign.ResultsIn 2008 about 0.8 Million CT procedures (~ 100 CT examinations / 1000 population) were performed in the country, leading to a collective effective dose of more than 6000 man.Sv (0.8 mSv/caput). In a decade the frequency of CT examinations averaged over the population and the associated average effective dose per caput increased by a factor of 2.2 and 2.9 respectively.ConclusionsAlthough the contribution of CT to the total medical X-rays is 6% in terms of the frequency, it represents 68% in terms of the collective effective dose. These results are comparable to those reported in a number of countries in Europe and America with similar health level.

[1]  David J Brenner,et al.  Should We be Concerned About the Rapid Increase in CT Usage? , 2010, Reviews on environmental health.

[2]  B. Burnand,et al.  NATION-WIDE SURVEY ON RADIATION DOSES IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY IN SWITZERLAND IN 1998 , 2002, Health physics.

[3]  Abbas Aroua,et al.  EXPOSURE OF THE SWISS POPULATION BY MEDICAL X-RAYS: 2008 REVIEW , 2012, Health physics.

[4]  Wolfgang Weiss International Evaluation of the Research Activities of the Finnish Radiation and Nuclear Safety Authority (STUK) , 2006 .

[5]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[6]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[7]  F R Verdun,et al.  Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels. , 2010, Radiation protection dosimetry.

[8]  F R Verdun,et al.  EXPOSURE OF THE SWISS POPULATION BY RADIODIAGNOSTICS: 2003 REVIEW , 2007, Health physics.

[9]  W. Eckelman,et al.  NCRP report no. 93: Ionizing radiation exposure of the population of the United States: National Council on Radiation Protection and Measurements, Bethesda, Maryland (1987). US$15.00 , 1988 .

[10]  岩崎 民子 SOURCES AND EFFECTS OF IONIZING RADIATION : United Nations Scientific Committee on the Effects of Atomic Radiation UNSCEAR 2000 Report to the General Assembly, with Scientific Annexes , 2002 .

[11]  B. Burnand,et al.  Dosimetric aspects of a national survey of diagnostic and interventional radiology in Switzerland. , 2002, Medical physics.