Detecting and adjusting for artifacts in fMRI time series data

We present a new method to detect and adjust for noise and artifacts in functional MRI time series data. We note that the assumption of stationary variance, which is central to the theoretical treatment of fMRI time series data, is often violated in practice. Sporadic events such as eye, mouth, or arm movements can increase noise in a spatially global pattern throughout an image, leading to a non-stationary noise process. We derive a restricted maximum likelihood (ReML) algorithm that estimates the variance of the noise for each image in the time series. These variance parameters are then used to obtain a weighted least squares estimate of the regression parameters of a linear model. We apply this approach to a typical fMRI experiment with a block design and show that the noise estimates strongly vary across different images and that our method detects and appropriately weights images that are affected by artifacts. Furthermore, we show that the noise process has a global spatial distribution and that the variance increase is multiplicative rather than additive. The new algorithm results in significantly increased sensitivity in the ability to detect regions of activation. The new method may be particularly useful for studies that involve special populations (e.g., children or elderly) where sporadic, artifact-generating events are more likely.

[1]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited—Again , 1995, NeuroImage.

[2]  Karl J. Friston,et al.  Variability in fMRI: An Examination of Intersession Differences , 2000, NeuroImage.

[3]  R. Weisskoff,et al.  Effect of temporal autocorrelation due to physiological noise and stimulus paradigm on voxel‐level false‐positive rates in fMRI , 1998, Human brain mapping.

[4]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[5]  R. Buxton,et al.  Estimation of respiration‐induced noise fluctuations from undersampled multislice fMRI data † , 2001, Magnetic resonance in medicine.

[6]  Alan C. Evans,et al.  A general statistical analysis for fMRI data , 2000, NeuroImage.

[7]  R. Turner,et al.  Event-Related fMRI: Characterizing Differential Responses , 1998, NeuroImage.

[8]  M. D’Esposito,et al.  Empirical analyses of BOLD fMRI statistics. I. Spatially unsmoothed data collected under null-hypothesis conditions. , 1997, NeuroImage.

[9]  Thomas E. Nichols,et al.  Diagnosis and exploration of massively univariate neuroimaging models , 2003, NeuroImage.

[10]  R W Cox,et al.  Magnetic field changes in the human brain due to swallowing or speaking , 1998, Magnetic resonance in medicine.

[11]  Karl J. Friston,et al.  A unified statistical approach for determining significant signals in images of cerebral activation , 1996, Human brain mapping.

[12]  J. Lewin,et al.  Inadequacy of motion correction algorithms in functional MRI: Role of susceptibility‐induced artifacts , 1997, Journal of magnetic resonance imaging : JMRI.

[13]  Mark D'Esposito,et al.  Variation of BOLD hemodynamic responses across subjects and brain regions and their effects on statistical analyses , 2004, NeuroImage.

[14]  E Zarahn,et al.  Empirical analyses of BOLD fMRI statistics. II. Spatially smoothed data collected under null-hypothesis and experimental conditions. , 1997, NeuroImage.

[15]  Karl J. Friston,et al.  Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.

[16]  R. Turner,et al.  Characterization and Correction of Interpolation Effects in the Realignment of fMRI Time Series , 2000, NeuroImage.

[17]  Stephen M. Smith,et al.  Temporal Autocorrelation in Univariate Linear Modeling of FMRI Data , 2001, NeuroImage.

[18]  Michael S Beauchamp,et al.  Detection of eye movements from fMRI data , 2003, Magnetic resonance in medicine.

[19]  Karl J. Friston,et al.  To Smooth or Not to Smooth? Bias and Efficiency in fMRI Time-Series Analysis , 2000, NeuroImage.

[20]  M. D’Esposito,et al.  The Variability of Human, BOLD Hemodynamic Responses , 1998, NeuroImage.

[21]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[22]  R W Cox,et al.  Event‐related fMRI of tasks involving brief motion , 1999, Human brain mapping.

[23]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited , 1995, NeuroImage.

[24]  Karl J. Friston,et al.  Modelling Geometric Deformations in Epi Time Series , 2022 .

[25]  T. Speed,et al.  Restricted Maximum Likelihood (REML) , 2006 .