Microwave imaging for thermal therapy monitoring: temperature accuracy and image reconstruction time improvements

Microwave imaging has been investigated as a method of non-invasively estimating tissue electrical properties especially the conductivity, which is highly temperature dependent, as a means of monitoring thermal therapy. The technique we have chosen utilizes an iterative Gauss-Newton approach to converge on the correct property distribution. A previous implementation utilizing the complex form (CF) of the electric fields along with a sub-optimal phantom experimental configuration resulted in imaging temperature accuracy of only 1.6°C. Applying the log-magnitude/phase form (LMPF) of the algorithm has resulted in imaging accuracy on the order of 0.3°C which is a significant advance for the area of treatment monitoring. The LMPF algorithm was originally introduced as a way to reconstruct images of large, high-contrast scatterers as is the case in breast imaging. However, recent analysis of the Jacobian matrices for the comparable implementations has shown that the reconstruction problem in the new formulation more closely resembles a linear task as is the case in x-ray computed tomography. The comparisons were performed by examining plots of the Jacobian matrix terms for fixed transmit and receive antennas which demonstrated higher sensitivity in the center of the imaging zone along with narrower paths of senstivity between the atnenna pair for the LMPF algorithm. Animal model experiments have also been performed to validate these capabilities in a more realistic setting. Finally, the overall computational efficiency has been significantly enhanced through the use of the adjoint image reconstruction approach. This enables us to reconstruct images in roughly one minute which is essential if the approach is to be used as a therapy feedback mechanism.

[1]  S L George,et al.  Sensitivity of hyperthermia trial outcomes to temperature and time: implications for thermal goals of treatment. , 1993, International journal of radiation oncology, biology, physics.

[2]  M. Amichetti,et al.  Report of long-term follow-up in a randomized trial comparing radiation therapy and radiation therapy plus hyperthermia to metastatic lymph nodes in stage IV head and neck patients. , 1994, International Journal of Radiation Oncology, Biology, Physics.

[3]  P Stauffer,et al.  Non-invasive temperature profile estimation in a lossy medium based on multi-band radiometric signals sensed by a microwave dual-purpose body-contacting antenna , 2002, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  K Paulsen,et al.  Non-invasive thermal assessment of tissue phantoms using an active near field microwave imaging technique. , 1998, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[5]  A. Hart,et al.  Comparison of radiotherapy alone with radiotherapy plus hyperthermia in locally advanced pelvic tumours: a prospective, randomised, multicentre trial , 2000, The Lancet.

[6]  P. VanBaren,et al.  Noninvasive real-time multipoint temperature control for ultrasound phased array treatments , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  K D Paulsen,et al.  Initial in vivo experience with EIT as a thermal estimator during hyperthermia. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[8]  K D Paulsen,et al.  Image accuracy improvements in microwave tomographic thermometry: phantom experience , 2003, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[9]  B. Pogue,et al.  Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery , 2001, IEEE Transactions on Medical Imaging.

[10]  Shireen D. Geimer,et al.  Microwave image reconstruction from 3-D fields coupled to 2-D parameter estimation , 2004, IEEE Transactions on Medical Imaging.

[11]  H C Charles,et al.  1H MRI phase thermometry in vivo in canine brain, muscle, and tumor tissue. , 1996, Medical physics.