Nonlinear integral sliding mode variable structure control for two-tank system with input — Limitation

To deal with the unsatisfactory transient response of the conventional integral sliding mode control (ISMC), A nonlinear integral sliding mode controller (NISMC) is proposed in this paper, which uses a smooth nonlinear function with “small error amplification and large error saturation” property, meanwhile, takes the limited input into account. The proposed NISMC improves the transient performance, i.e., less controller chattering and less steady error. The two-tank system is usually treated as a paradigm to test the control algorithms. Five kinds of sliding-mode control methods (SMC) are used to control the two-tank liquid level to test the performance. The simulation and experimental results show that the proposed NISMC has the superior performance as compared to the comparison methods.

[1]  Iztok Fister,et al.  Parameter tuning of PID controller with reactive nature-inspired algorithms , 2016, Robotics Auton. Syst..

[2]  Zhao Ke-you Analysis and design for single input linear systems subject to input saturation and uncertainty , 2005 .

[3]  Aman Kumar,et al.  Level control of two tank system by fractional order integral state feedback controller tuned by PSO with experimental validation , 2016, 2016 IEEE First International Conference on Control, Measurement and Instrumentation (CMI).

[4]  T. Chern,et al.  Design of integral variable structure controller and application to electrohydraulic velocity servosystems , 1991 .

[5]  D. Ho,et al.  Design of sliding mode control for nonlinear stochastic systems subject to actuator nonlinearity , 2006 .

[6]  D. Cho,et al.  Sliding mode and classical controllers in magnetic levitation systems , 1993, IEEE Control Systems.

[7]  Zafer Aydogmus,et al.  Implementation of a fuzzy-based level control using SCADA , 2009, Expert Syst. Appl..

[8]  Makoto Yokoyama,et al.  A Design Method of Sliding Mode Controller for Servo-systems Subject to Actuator Saturation , 2003 .

[9]  Hu Shousong,et al.  Adaptive Sliding Mode Tracking Control with Saturated Dead-zone Nonlinear Inputs , 2009 .

[10]  Myung-Joong Youn,et al.  Robust nonlinear speed control of PM synchronous motor using boundary layer integral sliding mode control technique , 2000, IEEE Trans. Control. Syst. Technol..

[11]  N. A. Selamat,et al.  Comparison of LQR and PID controller tuning using PSO for Coupled Tank System , 2015, 2015 IEEE 11th International Colloquium on Signal Processing & Its Applications (CSPA).

[12]  Suk-Kyo Hong,et al.  Antisway Tracking Control of Overhead Cranes With System Uncertainty and Actuator Nonlinearity Using an Adaptive Fuzzy Sliding-Mode Control , 2008, IEEE Transactions on Industrial Electronics.

[13]  Norhaliza Abdul Wahab,et al.  Control of a Two Layered Coupled Tank : Application of IMC , IMC-PI and Pole-Placement PI Controllers , 2022 .

[14]  Wahyudi,et al.  ROBUST ANTI-WINDUP PID CONTROL OF A COUPLE INDUSTRIAL TANK SYSTEM , .

[15]  Makoto Yokoyama,et al.  A DESIGN METHOD OF SLIDING MODE CONTROLLER FOR SERVO-SYSTEMS SUBJECT TO ACTUATOR SATURATION , 2002 .

[16]  Wenlong Fu,et al.  An adaptively fast fuzzy fractional order PID control for pumped storage hydro unit using improved gravitational search algorithm , 2016 .

[17]  Yu-Shen Lu Integral variable-structure control with variable-structure sliding dynamics for antireset windup , 2008 .

[18]  Dong-Juan Li Neural network control for a class of continuous stirred tank reactor process with dead-zone input , 2014, Neurocomputing.

[19]  Jie Li,et al.  Conditional integral sliding mode variable structure control for two-tank system , 2017, 2017 12th IEEE Conference on Industrial Electronics and Applications (ICIEA).

[20]  Soumya Ranjan Mahapatro,et al.  Internal model based PI controller design for the coupled tank system: An experimental study , 2016, 2016 IEEE First International Conference on Control, Measurement and Instrumentation (CMI).

[21]  Pedro Ponce,et al.  A novel robust liquid level controller for coupled-tanks systems using artificial hydrocarbon networks , 2015, Expert Syst. Appl..

[22]  Hassan K. Khalil,et al.  Robust output feedback regulation of minimum-phase nonlinear systems using conditional integrators , 2005, Autom..

[23]  R. Kiruba,et al.  Design and implementation of two tank conical interacting system using intelligent technique (PSO) , 2015, 2015 International Conference on Advanced Computing and Communication Systems.

[24]  Sankata B. Prusty,et al.  A novel fuzzy based adaptive control of the four tank system , 2015, Proceedings of the 2015 Third International Conference on Computer, Communication, Control and Information Technology (C3IT).

[25]  Marcin Mrugalski,et al.  An unscented Kalman filter in designing dynamic GMDH neural networks for robust fault detection , 2013, Int. J. Appl. Math. Comput. Sci..

[26]  Eduard Petlenkov,et al.  Design and implementation of fractional-order PID controllers for a fluid tank system , 2013, 2013 American Control Conference.

[27]  Jung-Hoon Lee Highly robust position control of BLDDSM using an improved integral variable structure systems , 2006, Autom..