Mitigation of Rooftop Solar PV Impacts and Evening Peak Support by Managing Available Capacity of Distributed Energy Storage Systems

A high penetration of rooftop solar photovoltaic (PV) resources into low-voltage (LV) distribution networks creates reverse power-flow and voltage-rise problems. This generally occurs when the generation from PV resources substantially exceeds the load demand during high insolation period. This paper has investigated the solar PV impacts and developed a mitigation strategy by an effective use of distributed energy storage systems integrated with solar PV units in LV networks. The storage is used to consume surplus solar PV power locally during PV peak, and the stored energy is utilized in the evening for the peak-load support. A charging/discharging control strategy is developed taking into account the current state of charge (SoC) of the storage and the intended length of charging/discharging period to effectively utilize the available capacity of the storage. The proposed strategy can also mitigate the impact of sudden changes in PV output, due to unstable weather conditions, by putting the storage into a short-term discharge mode. The charging rate is adjusted dynamically to recover the charge drained during the short-term discharge to ensure that the level of SoC is as close to the desired SoC as possible. A comprehensive battery model is used to capture the realistic behavior of the distributed energy storage units in a distribution feeder. The proposed PV impact mitigation strategy is tested on a practical distribution network in Australia and validated through simulations.

[1]  Sonia Martínez,et al.  Storage Size Determination for Grid-Connected Photovoltaic Systems , 2011, IEEE Transactions on Sustainable Energy.

[2]  L.-A. Dessaint,et al.  A Generic Battery Model for the Dynamic Simulation of Hybrid Electric Vehicles , 2007, 2007 IEEE Vehicle Power and Propulsion Conference.

[3]  P. Rodriguez,et al.  Local Reactive Power Control Methods for Overvoltage Prevention of Distributed Solar Inverters in Low-Voltage Grids , 2011, IEEE Journal of Photovoltaics.

[4]  M. Thomson,et al.  Network Power-Flow Analysis for a High Penetration of Distributed Generation , 2006, IEEE Transactions on Power Systems.

[5]  Yuzuru Ueda,et al.  STUDY ON THE OVER VOLTAGE PROBLEM AND BATTERY OPERATION FOR GRID-CONNECTED RESIDENTIAL PV SYSTEMS , 2007 .

[6]  K. M. Muttaqi,et al.  Distributed energy storage for mitigation of voltage-rise impact caused by rooftop solar PV , 2012, 2012 IEEE Power and Energy Society General Meeting.

[7]  M. McGranaghan,et al.  Sim City , 2011, IEEE Power and Energy Magazine.

[8]  Kamel Khouzam Technical and economic assessment of utility interactive PV systems for domestic applications in south east Queensland , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[9]  Gilbert M. Masters,et al.  Renewable and Efficient Electric Power Systems: Masters/Electric Power Systems , 2004 .

[10]  B. Kroposki,et al.  Distribution System Voltage Performance Analysis for High-Penetration PV , 2008, 2008 IEEE Energy 2030 Conference.

[11]  L.A.F. Ferreira,et al.  Distributed Reactive Power Generation Control for Voltage Rise Mitigation in Distribution Networks , 2008, IEEE Transactions on Power Systems.

[12]  N.K. Medora,et al.  Dynamic Battery Modeling of Lead-Acid Batteries using Manufacturers' Data , 2005, INTELEC 05 - Twenty-Seventh International Telecommunications Conference.

[13]  R. Rynkiewicz Discharge and charge modeling of lead acid batteries , 1999, APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285).

[14]  K. M. Muttaqi,et al.  A Three-Phase Power Flow Approach for Integrated 3-Wire MV and 4-Wire Multigrounded LV Networks With Rooftop Solar PV , 2013, IEEE Transactions on Power Systems.

[15]  D. Linden Handbook Of Batteries , 2001 .

[16]  Hui Li,et al.  Coordinated Control of Distributed Energy Storage System With Tap Changer Transformers for Voltage Rise Mitigation Under High Photovoltaic Penetration , 2012, IEEE Transactions on Smart Grid.

[17]  M. Tartaglia,et al.  Electrical Impact of Photovoltaic Plant in Distributed Network , 2007, IEEE Transactions on Industry Applications.

[18]  P.A.N. Garcia,et al.  Three-Phase Power Flow Based on Four-Conductor Current Injection Method for Unbalanced Distribution Networks , 2008, IEEE Transactions on Power Systems.

[19]  I. Papic Simulation model for discharging a lead-acid battery energy storage system for load leveling , 2006, 2006 IEEE Power Engineering Society General Meeting.

[20]  R Tonkoski,et al.  Coordinated Active Power Curtailment of Grid Connected PV Inverters for Overvoltage Prevention , 2011, IEEE Transactions on Sustainable Energy.

[21]  Gilbert M. Masters,et al.  Renewable and Efficient Electric Power Systems , 2004 .

[22]  D. Turcotte,et al.  Impact of High PV Penetration on Voltage Profiles in Residential Neighborhoods , 2012, IEEE Transactions on Sustainable Energy.

[23]  L.A. Kojovic,et al.  Summary of Distributed Resources Impact on Power Delivery Systems , 2008, IEEE Transactions on Power Delivery.