Harmonic Mitigation, Maximum Power Point Tracking, and Dynamic Performance of Variable-speed Grid-connected Wind Turbine

Abstract This article presents a method for harmonic mitigation and maximum power point tracking for a variable-speed grid-connected 20-kW wind turbine. The wind energy conversion system consists of a permanent magnet synchronous generator driven by variable-speed 20-kW wind turbine. The output of the permanent magnet synchronous generator is connected to a single-switch three-phase boost rectifier to generate DC voltage, which feeds a current-controlled inverter to interface the system with the electric utility. The single-switch three-phase boost rectifier is an active power factor correction technique to maintain the power factor at the permanent magnet synchronous generator side to nearly unity and mitigate the permanent magnet synchronous generator current harmonics. To mitigate inverter output current and voltage harmonics, an LCL filter has been used. A complete analysis of the harmonic content has been done everywhere in the system. The results show that the proposed maximum power point tracking control strategy succeeded to track the maximum wind power irrespective of the wind speed. This strategy in presence of an LCL filter achieved harmonic mitigation at the permanent magnet synchronous generator and inverter output sides. The dynamic response of the wind energy conversion system is tested under a three-phase fault condition. For comparison purposes, an active power filter is designed and checked against the single-switch three-phase boost rectifier for harmonic mitigation at the permanent magnet synchronous generator side.

[1]  APEC 2000 - Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition , 2000, APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058).

[2]  L. J. Borle,et al.  Ramptime Current Control , 1996 .

[3]  Torbjörn Thiringer,et al.  Control by variable rotor speed of a fixed-pitch wind turbine operating in a wide speed range , 1993 .

[4]  Masaaki Sakui,et al.  A maximum power control of wind generator system using a permanent magnet synchronous generator and a boost chopper circuit , 2002, Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579).

[5]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[6]  Liuchen Chang,et al.  An intelligent maximum power extraction algorithm for inverter-based variable speed wind turbine systems , 2004 .

[7]  Ion Boldea,et al.  Variable Speed Generators , 2005 .

[8]  Phoivos D. Ziogas,et al.  An active power factor correction technique for three-phase diode rectifiers , 1989 .

[9]  L. J. Borle,et al.  Zero average current error controlled power flow for AC-DC power converters , 1995 .

[10]  M. Negnevitsky,et al.  Control of a stand alone variable speed wind turbine with a permanent magnet synchronous generator , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[11]  Vahan Gevorgian,et al.  A peak power tracker for small wind turbines in battery charging applications , 1999 .

[12]  J. Stensby,et al.  Phase-Locked Loops: Theory and Applications , 1997 .

[13]  Zhe Chen,et al.  Overview of different wind generator systems and their comparisons , 2008 .

[14]  Kostas Kalaitzakis,et al.  Design of a maximum power tracking system for wind-energy-conversion applications , 2006, IEEE Transactions on Industrial Electronics.

[15]  Hui Li,et al.  Neural-network-based sensorless maximum wind energy capture with compensated power coefficient , 2004, IEEE Transactions on Industry Applications.

[16]  D. S. Zinger,et al.  A variable speed wind turbine power control , 1997 .

[17]  Peter Mutschler,et al.  The influence of control strategies on the energy capture of wind turbines , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[18]  C. V. Nayar,et al.  ZACE current controlled power flow for AC-DC power converters , 1994, Proceedings of 1994 Power Electronics Specialist Conference - PESC'94.

[19]  Mazen Abdel-Salam,et al.  Ramptime Current -Controlled APF for Harmonic Mitigation, Power Factor Correction and Load Balancing , 2010 .

[20]  K. Tan,et al.  Optimum control strategies in energy conversion of PMSG wind turbine system without mechanical sensors , 2004, IEEE Transactions on Energy Conversion.

[21]  L. J. Borle A three-phase grid-connected inverter with improved ramptime current control in programmable logic , 1998, 1998 International Conference on Power Electronic Drives and Energy Systems for Industrial Growth, 1998. Proceedings..

[22]  Vassilios G. Agelidis,et al.  A new digital zero average current error control algorithm for inverters , 2000 .

[23]  Syed Islam,et al.  Power Electronics for Renewable Energy Sources , 2011 .