Break point diagnosis of grounding grids using transient electromagnetic apparent resistivity imaging
暂无分享,去创建一个
[1] X.-L. Zhang,et al. Development of an Electrochemical In Situ Detection Sensor for Grounding Grid Corrosion , 2010 .
[2] Xuesong Zhu,et al. Research on Ground Grid Diagnosis with Topological Decomposition and Node Voltage Method , 2012, 2012 Spring Congress on Engineering and Technology.
[3] Huaiqing Zhang,et al. Transient process and optimal design of receiver coil for small‐loop transient electromagnetics , 2014 .
[4] B. Zhang,et al. Analysis of Transient Performance of Grounding System Considering Soil Ionization by Time Domain Method , 2013, IEEE Transactions on Magnetics.
[5] L. Grcev,et al. Lightning Surge Efficiency of Grounding Grids , 2011, IEEE Transactions on Power Delivery.
[6] H. Motoyama,et al. Electromagnetic Transient Response of Buried Bare Wire and Ground Grid , 2007, IEEE Transactions on Power Delivery.
[7] Yaqing Liu,et al. An engineering model for transient analysis of grounding system under lightning strikes: nonuniform transmission-line approach , 2005, IEEE Transactions on Power Delivery.
[8] G. W. Hohmann,et al. 4. Electromagnetic Theory for Geophysical Applications , 1987 .
[9] Oliver Kuras,et al. Recent developments in the direct-current geoelectrical imaging method , 2013 .
[10] Dragan Poljak,et al. Wire antenna model for transient analysis of simple grounding systems. Part II : the horizontal grounding electrode , 2006 .
[11] B. Zhang,et al. Diagnosis of breaks in substation's grounding grid by using the electromagnetic method , 2002 .
[12] N. D. Hatziargyriou,et al. Time Domain Analysis of Grounding Electrodes' Impulse Response , 2002, IEEE Power Engineering Review.
[13] M. Nabighian. Quasi-static transient response of a conducting half-space; an approximate representation , 1979 .
[14] D. Mukhedkar,et al. Transient Performance of Grounding Grids , 1989, IEEE Power Engineering Review.
[15] Yang Liu,et al. A magnetic detecting and evaluation method of substation’s grounding grids with break and corrosion , 2010 .
[16] Z.D. Grcev,et al. Frequency Dependent and Transient Characteristics of Substation Grounding Systems , 1997, IEEE Power Engineering Review.
[17] Ke Wu,et al. Fast and Accurate Transient Analysis of Buried Wires and its Applications , 2014, IEEE Transactions on Electromagnetic Compatibility.
[18] Zhibin Zhao,et al. Grounding Performance Analysis of the Substation Grounding Grids by Finite Element Method in Frequency Domain , 2006, IEEE Transactions on Magnetics.
[19] Jiansheng Yuan,et al. Simulation of substation grounding grids with unequal-potential , 2000 .
[20] Dragan Poljak,et al. Wire antenna versus modified transmission line approach to the transient analysis of grounding grid , 2011 .
[21] F. Dawalibi,et al. Analysis of Grounding Systems in Soils with Finite Volumes of Different Resistivities , 2002, IEEE Power Engineering Review.
[22] F. Dawalibi. Electromagnetic Fields Generated by Overhead and Buried Short Conductors Part 2 - Ground Networks , 1986, IEEE Transactions on Power Delivery.
[23] Rino Lucić,et al. Grounding grid transient analysis using the improved transmission line model based on the finite element method , 2013 .