In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty

The objective of this study was to investigate biomechanics of TKA patients during high flexion. Six patients (seven knees) with a posterior-substituting TKA and weight-bearing flexion >130° were included in the study. The six degree-of-freedom kinematics, tibiofemoral contact, and cam-post contact were measured during a deep knee bend using dual-plane fluoroscopy. The patients achieved average weight-bearing flexion of 139.5 ± 4.5°. Posterior femoral translation and internal tibial rotation increased steadily beyond 90° flexion, and a sharp increase in varus rotation was noted at maximum flexion. Initial cam-post engagement was observed at 100.3 ± 6.7° flexion. Five knees had cam-post disengagement before maximum flexion. Lateral femoral condylar lift-off was found in five out of seven knees at maximum flexion, and medial condylar lift-off was found in one knee. Future studies should investigate if the kinematic characteristics of posterior-substituting TKA knees noted in this study are causative factors of high knee flexion.

[1]  S. Banks,et al.  Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. , 2002, The Journal of bone and joint surgery. British volume.

[2]  Jeremy F. Suggs,et al.  Patient function after a posterior stabilizing total knee arthroplasty: cam–post engagement and knee kinematics , 2008, Knee Surgery, Sports Traumatology, Arthroscopy.

[3]  B. Morrey Factors Affecting Flexion after Total Knee Arthroplasty , 2008 .

[4]  Jeremy F. Suggs,et al.  Investigation of in-vivo total knee arthroplasty biomechanics using a dual fluoroscopic imaging system , 2007 .

[5]  S. Banks,et al.  A kinematic comparison of fixed- and mobile-bearing knee replacements. , 2006, The Journal of bone and joint surgery. British volume.

[6]  Thomas P Andriacchi,et al.  The use of functional analysis in evaluating knee kinematics. , 2003, Clinical orthopaedics and related research.

[7]  S. Banks,et al.  Kneeling kinematics after total knee arthroplasty: anterior-posterior contact position of a standard and a high-flex tibial insert design. , 2007, The Journal of arthroplasty.

[8]  J B Stiehl,et al.  Femoral condylar lift-off in vivo in total knee arthroplasty. , 2001, The Journal of bone and joint surgery. British volume.

[9]  Satoshi Hamai,et al.  Kinematic analysis of kneeling in cruciate‐retaining and posterior‐stabilized total knee arthroplasties , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  T-H Kim,et al.  The NexGen LPS-flex to the knee prosthesis at a minimum of three years. , 2008, The Journal of bone and joint surgery. British volume.

[11]  R. Komistek,et al.  The influence of femoral condylar lift-off on the wear of artificial knee joints , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  U P Wyss,et al.  Hip, knee, and ankle kinematics of high range of motion activities of daily living , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[13]  Guoan Li,et al.  In vivo kneeling biomechanics after posterior stabilized total knee arthroplasty , 2007, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[14]  U P Wyss,et al.  Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants , 2001, International journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation.

[15]  K. Park,et al.  Functional Disabilities and Issues of Concern in Female Asian Patients Before TKA , 2007, Clinical orthopaedics and related research.

[16]  K. Yoon,et al.  High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. , 2007, The Journal of bone and joint surgery. British volume.

[17]  D. Dennis,et al.  The Impact of Femoral Component Rotational Alignment on Condylar Lift-Off , 2003, Clinical orthopaedics and related research.

[18]  Todd Johnson,et al.  Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty. , 2006, The Journal of bone and joint surgery. American volume.

[19]  Guoan Li,et al.  Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  Jeffrey T. Bingham,et al.  Effect of Posterior Cruciate Ligament Deficiency on in vivo Translation and Rotation of the Knee during Weightbearing Flexion , 2008, The American journal of sports medicine.

[21]  F. Amirouche,et al.  Optimisation of the posterior stabilised tibial post for greater femoral rollback after total knee arthroplasty—a finite element analysis , 2009, International Orthopaedics.

[22]  Harry E Rubash,et al.  Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: an in vitro robotic experimental investigation. , 2004, The Journal of bone and joint surgery. American volume.

[23]  D. Dennis,et al.  A Posterior-Stabilized Total Knee Arthroplasty Shows Condylar Lift-off during Deep Knee Bends , 2005, Clinical orthopaedics and related research.

[24]  Todd Johnson,et al.  Biomechanics of Posterior-Substituting Total Knee Arthroplasty: An In Vitro Study , 2002, Clinical orthopaedics and related research.