Minimum Variance Signal Selection for Aorta Radius Estimation Using Radar

This paper studies the optimum signal choice for the estimation of the aortic blood pressure via aorta radius, using a monostatic radar configuration. The method involves developing the Cramér-Rao lower bound (CRLB) for a simplified model. The CRLB for model parameters are compared with simulation results using a grid-based approach for estimation. The CRLBs are within the 99% confidence intervals for all chosen parameter values. The CRLBs show an optimal region within an ellipsoid centered at 1 GHz center frequency and 1.25 GHz bandwidth with axes of 0.5 GHz and 1 GHz, respectively. Calculations show that emitted signal energy to received noise spectral density should exceed for a precision of approximately 0.1 mm for a large range of model parameters. This implies a minimum average power of 0.4 . These values are based on optimistic assumptions. Reflections, improved propagation model, true receiver noise, and parameter ranges should be considered in a practical implementation.

[1]  David T. Westwick,et al.  Tumor Response Estimation in Radar-Based Microwave Breast Cancer Detection , 2008, IEEE Transactions on Biomedical Engineering.

[2]  Jong Yong Abdiel Foo,et al.  Pulse transit time as an indirect marker for variations in cardiovascular related reactivity. , 2006, Technology and health care : official journal of the European Society for Engineering and Medicine.

[3]  Ilangko Balasingham,et al.  A feasibility study on aortic pressure estimation using UWB radar , 2009, 2009 IEEE International Conference on Ultra-Wideband.

[4]  C. Fowler,et al.  Assessment of ultra-wideband (UWB) technology , 1990, IEEE Aerospace and Electronic Systems Magazine.

[5]  Marc M. Budge,et al.  Terminology for Describing the Elastic Behavior of Arteries , 2003 .

[6]  I.Ya. Immoreev Ultra-wideband radars: features and ways of development , 2005, European Radar Conference, 2005. EURAD 2005..

[7]  P. Verdonck,et al.  Development and modelling of arterial applanation tonometry: a review. , 2002, Technology and health care : official journal of the European Society for Engineering and Medicine.

[8]  Laura Anitori,et al.  FMCW radar for life-sign detection , 2009, 2009 IEEE Radar Conference.

[9]  Brian M. Sadler,et al.  A Survey of Time Delay Estimation Performance Bounds , 2006, Fourth IEEE Workshop on Sensor Array and Multichannel Processing, 2006..

[10]  Kiyomi Niki,et al.  Relationship between the pressure and diameter of the carotid artery in humans , 2000, Heart and Vessels.

[11]  Philip M. Woodward,et al.  Probability and Information Theory with Applications to Radar , 1954 .

[12]  R. Kattai,et al.  Continuous blood pressure monitoring during exercise using pulse wave transit time measurement , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Ehud Weinstein,et al.  Comparison of the Ziv-Zakai lower bound on time delay estimation with correlator performance , 1983, ICASSP.

[14]  Klaus Krickeberg,et al.  Probability and information theory II , 1969 .

[15]  G. Drummond,et al.  Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia. , 2006, British journal of anaesthesia.

[16]  Giuseppe Mancia,et al.  Non-invasive beat-to-beat blood pressure monitoring: new developments , 2003, Blood pressure monitoring.

[17]  S Marakas,et al.  Pressure-diameter relation of the human aorta. A new method of determination by the application of a special ultrasonic dimension catheter. , 1995, Circulation.

[18]  Harry L. Van Trees,et al.  Detection, Estimation, and Modulation Theory, Part I , 1968 .

[19]  B.D. Van Veen,et al.  An overview of ultra-wideband microwave imaging via space-time beamforming for early-stage breast-cancer detection , 2005, IEEE Antennas and Propagation Magazine.

[20]  Andreas Pommert,et al.  Creating a high-resolution spatial/symbolic model of the inner organs based on the Visible Human , 2001, Medical Image Anal..

[21]  L. Scharf,et al.  Statistical Signal Processing: Detection, Estimation, and Time Series Analysis , 1991 .

[22]  C. Gabriel Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies. , 1996 .