Surface plasmon resonance spectroscopy as an alternative for sensing heavy metal ions: a review

Purpose – The purpose of this paper is to review the novel application of surface plasmon resonance (SPR) in sensing heavy metal ions and the development of SPR to become an alternative heavy metal ions sensor. Design/methodology/approach – The possible dangerous toxic effects of heavy metal ions are revealed in the short introduction. The existing conventional methods for sensing heavy metal ions and their drawbacks are also discussed. To overcome these drawbacks, SPR has been investigated from the basic principle to the potential alternative in sensing heavy metal ions. Findings – Application of SPR in sensing heavy metal ions emerged a decade ago. A wide range of active layers or recognition elements (e.g. polymer, protein, nanoparticles) have been developed to combine with SPR. The detection limit, sensitivity and selectivity of SPR sensing in heavy metal ions have been improved from time to time, until the present. Originality/value – This paper provides up-to-date and systematic information on SPR s...

[1]  Laszlo Magos,et al.  The toxicology of mercury--current exposures and clinical manifestations. , 2003, The New England journal of medicine.

[2]  R. Goyer Results of lead research: prenatal exposure and neurological consequences. , 1996, Environmental Health Perspectives.

[3]  B. Sansoni,et al.  A review on activation analysis of air particulate matter , 1985 .

[4]  P. Avino,et al.  Heavy metal determination in atmospheric particulate matter by Instrumental Neutron Activation Analysis , 2008 .

[5]  Baobao Cao,et al.  Rapid detection of toxic metals in non-crushed oyster shells by portable X-ray fluorescence spectrometry. , 2010, Environmental pollution.

[6]  L. P. Eksperiandova,et al.  Analysis of waste water by x‐ray fluorescence spectrometry , 2002 .

[7]  Ó. Pozo,et al.  Method optimization for the determination of four mercury species by micro-liquid chromatography-inductively coupled plasma mass spectrometry coupling in environmental water samples. , 2006, Analytica chimica acta.

[8]  Reinhardt Willsch,et al.  Fiber optic sensor for adsorption studies using surface plasmon resonance , 1995, European Symposium on Optics for Environmental and Public Safety.

[9]  L. Moens,et al.  Inductively coupled plasma mass spectrometric determination of heavy metals in soil and sludge candidate reference materials , 1995 .

[10]  D. A. Russell,et al.  Novel determination of cadmium ions using an enzyme self-assembled monolayer with surface plasmon resonance , 2003 .

[11]  A. Raggi,et al.  Chromium determination in foods by quadrupole inductively coupled plasma–mass spectrometry with ultrasonic nebulization , 2003 .

[12]  N. Yusof,et al.  Surface Plasmon Resonance Optical Sensor for Detection of Essential Heavy Metal Ions with Potential for Toxicity: Copper, Zinc and Manganese Ions , 2011 .

[13]  S. Fujiwara,et al.  Rapid determination of arsenic species in freshwater organisms from the arsenic-rich Hayakawa River in Japan using HPLC-ICP-MS. , 2009, Chemosphere.

[14]  R. Naidu,et al.  Speciation of chromium in waste water using ion chromatography inductively coupled plasma mass spectrometry. , 2007, Talanta.

[15]  C. Schauer,et al.  Selective detection of hexachromium ions by localized surface plasmon resonance measurements using gold nanoparticles/chitosan composite interfaces. , 2009, The Analyst.

[16]  R. Wood,et al.  On a Remarkable Case of Uneven Distribution of Light in a Diffraction Grating Spectrum , 1902 .

[17]  R. Abdulah,et al.  Rapid and direct determination of selenium, copper, and zinc in blood plasma by flow injection-inductively coupled plasma-mass spectrometry , 2007, Biological Trace Element Research.

[18]  Karel Vytras,et al.  Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode , 2009 .

[19]  H. Weiss,et al.  Analytical investigations of phenyl arsenicals in groundwater. , 2008, Talanta.

[20]  Paul Westerhoff,et al.  Detection of arsenic in groundwater using a surface plasmon resonance sensor , 2007 .

[21]  M D McNeely,et al.  Atomic absorption spectrometry of nickel, copper, zinc, and lead in sweat collected from healthy subjects during sauna bathing. , 1973, Clinical chemistry.

[22]  Nongjian Tao,et al.  Detection of heavy metal ions in drinking water using a high-resolution differential surface plasmon resonance sensor. , 2005, Environmental science & technology.

[23]  J. Ivanova,et al.  Comparative evaluation of the possibilities of INAA, ED-XRF, ICP-AES and AAS in the analysis of plants , 1998 .

[24]  D. Bannon,et al.  Graphite furnace atomic absorption spectroscopic measurement of blood lead in matrix-matched standards. , 1994, Clinical chemistry.

[25]  K. Heumann,et al.  Simultaneous multi-species determination of trimethyllead, monomethylmercury and three butyltin compounds by species-specific isotope dilution GC–ICP–MS in biological samples , 2005, Analytical and bioanalytical chemistry.

[26]  E. Ortiz,et al.  Instrumental nuclear activation analysis (INAA) characterization of environmental air filter samples. , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[27]  M. Olivares,et al.  The Gastrointestinal Tract and Acute Effects of Copper in Drinking Water and Beverages , 1999, Reviews on environmental health.

[28]  M. Freitas,et al.  Air pollution at an urban traffic tunnel in Lisbon, Portugal: an INAA study. , 2011, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[29]  Nor Azah Yusof,et al.  Detection of mercury and copper ions using surface plasmon resonance optical sensor. , 2011 .

[30]  L. Teppo,et al.  Health effects of cadmium exposure - a review of the literature and a risk estimate , 1998 .

[31]  Ching-Mei Wu,et al.  Immobilization of metallothionein as a sensitive biosensor chip for the detection of metal ions by surface plasmon resonance. , 2004, Biosensors & bioelectronics.

[32]  W. Michaelis,et al.  Multi-element determination of dissolved heavy metal traces in sea water by total-reflection x-ray fluorescence spectrometry , 1985 .

[33]  R. Wood XLII. On a remarkable case of uneven distribution of light in a diffraction grating spectrum , 1902 .

[34]  Shaopeng Wang,et al.  Detection of heavy metal ions in water by high-resolution surface plasmon resonance spectroscopy combined with anodic stripping voltammetry. , 2007, Analytical chemistry.

[35]  E. Lai,et al.  Surface plasmon resonance sensor for Hg(II) detection by binding interactions with polypyrrole and 2-mercaptobenzothiazole , 2004 .

[36]  Shizhi Qian,et al.  Ultrasensitive detection of mercury (II) ions using electrochemical surface plasmon resonance with magnetohydrodynamic convection. , 2009, Journal of colloid and interface science.

[37]  Yan Du,et al.  Au NPs-enhanced surface plasmon resonance for sensitive detection of mercury(II) ions. , 2010, Biosensors & bioelectronics.

[38]  V. Talbot,et al.  Rapid multielement analysis of oyster and cockle tissue using X-ray fluorescence spectrometry, with application to reconnaissance marine pollution investigations. , 1987, The Science of the total environment.

[39]  R. Barnes Advances in inductively coupled plasma mass spectrometry: human nutrition and toxicology , 1993 .

[40]  R. Goyer Lead toxicity: from overt to subclinical to subtle health effects. , 1990, Environmental health perspectives.

[41]  Sung-Hoon Kim,et al.  Optical detection of Cu2+ ion using a SQ-dye containing polymeric thin-film on Au surface , 2001 .

[42]  N. Stradiotto,et al.  Simultaneous determination of trace amounts of zinc, lead and copper in rum by anodic stripping voltammetry. , 1997, Talanta.

[43]  R. Muzzarelli,et al.  The determination of copper in sea water by atomic absorption spectrometry with a graphite atomizer after elution from chitosan. , 1974, Analytica chimica acta.

[44]  Luqman Chuah Abdullah,et al.  Surface Plasmon Resonance Sensing Detection of Mercury and Lead Ions Based on Conducting Polymer Composite , 2011, PLoS ONE.

[45]  P. Jitaru,et al.  Simultaneous multi-elemental speciation analysis of organometallic compounds by solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight-mass spectrometry , 2004 .

[46]  Lih-Yuan Lin,et al.  Utilization of albumin-based sensor chips for the detection of metal content and characterization of metal–protein interaction by surface plasmon resonance , 2005 .

[47]  S M El-Bahi,et al.  Heavy metals and rare earth elements in phosphate fertilizer components using instrumental neutron activation analysis. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[48]  I. Shtangeeva Variation of the elemental composition of plants and soils , 1994 .

[49]  Bin Hu,et al.  Simultaneous separation and speciation of inorganic As(III)/As(V) and Cr(III)/Cr(VI) in natural waters utilizing capillary microextraction on ordered mesoporous Al2O3 prior to their on-line determination by ICP-MS. , 2008, Journal of hazardous materials.

[50]  Zi-Ling Xue,et al.  Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode. , 2010, Talanta.

[51]  Yanju Wang,et al.  Studies of metal ion binding by apo-metallothioneins attached onto preformed self-assembled monolayers using a highly sensitive surface plasmon resonance spectrometer. , 2007, Sensors and actuators. B, Chemical.

[52]  Taewook Kang,et al.  Surface plasmon resonance analysis of aqueous copper ions with amino-terminated self-assembled monolayers , 2007 .

[53]  T. Hettipathirana Simultaneous determination of parts-per-million level Cr, As, Cd and Pb, and major elements in low level contaminated soils using borate fusion and energy dispersive X-ray fluorescence spectrometry with polarized excitation , 2004 .

[54]  J. Yi,et al.  Surface plasmon resonance analysis of aqueous mercuric ions , 2004 .

[55]  A. Sigleo,et al.  Concentrations of elements in the National Bureau of Standards' bituminous and subbituminous coal standard reference materials , 1980 .

[56]  M. Trevisan,et al.  Characterization of mercury species in soils by HPLC-ICP-MS and measurement of fraction removed by diffusive gradient in thin films. , 2008, Talanta.

[57]  G. Stingeder,et al.  CE-ICP-SFMS and HPIC-ICP-SFMS for arsenic speciation in soil solution and soil water extractsPresented at the 2002 Winter Conference on Plasma Spectrochemistry, Scottsdale, AZ, USA, January 6???12, 2002. , 2002 .

[58]  P. Ostapczuk,et al.  Application of differential pulse anodic stripping voltammetry to the determination of heavy metals in environmental samples. , 1987, The Science of the total environment.

[59]  E. Marguí,et al.  Application of X-ray fluorescence spectrometry to determination and quantitation of metals in vegetal material , 2009 .

[60]  A. Manivannan,et al.  Detection of trace levels of Pb2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry , 2006 .

[61]  R. Magee,et al.  Determination of copper in sea water by atomic absorption spectroscopy , 1965 .

[62]  M. Stiff,et al.  The determination of cadmium. lead, copper and zinc in ground water, estuarine water, sewage and sewage effluent by anodic stripping voltammetry , 1975 .

[63]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[64]  B. Liedberg,et al.  Principles of biosensing with an extended coupling matrix and surface plasmon resonance , 1993 .

[65]  M. Piepenbrink,et al.  Developmental immunotoxicology of lead. , 2004, Toxicology and applied pharmacology.

[66]  H. Gonick,et al.  Is lead exposure the principal cause of essential hypertension? , 2002, Medical hypotheses.