Development of a Small-Sized, Flexible, and Insertable Fiber-Optic Radiation Sensor for Gamma-Ray Spectroscopy

We fabricated a small-sized, flexible, and insertable fiber-optic radiation sensor (FORS) that is composed of a sensing probe, a plastic optical fiber (POF), a photomultiplier tube (PMT)-amplifier system, and a multichannel analyzer (MCA) to obtain the energy spectra of radioactive isotopes. As an inorganic scintillator for gamma-ray spectroscopy, a cerium-doped lutetium yttrium orthosilicate (LYSO:Ce) crystal was used and two solid-disc type radioactive isotopes with the same dimensions, cesium-137 (Cs-137) and cobalt-60 (Co-60), were used as gamma-ray emitters. We first determined the length of the LYSO:Ce crystal considering the absorption of charged particle energy and measured the gamma-ray energy spectra using the FORS. The experimental results demonstrated that the proposed FORS can be used to discriminate species of radioactive isotopes by measuring their inherent energy spectra, even when gamma-ray emitters are mixed. The relationship between the measured photon counts of the FORS and the radioactivity of Cs-137 was subsequently obtained. The amount of scintillating light generated from the FORS increased by increasing the radioactivity of Cs-137. Finally, the performance of the fabricated FORS according to the length and diameter of the POF was also evaluated. Based on the results of this study, it is anticipated that a novel FORS can be developed to accurately measure the gamma-ray energy spectrum in inaccessible locations such as narrow areas and holes.

[1]  N. Sharip,et al.  Efficiency and resolution of HPGe and NaI(Tl) detectors using gamma-ray spectroscopy , 2012 .

[2]  T. Li,et al.  Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[3]  C. V. van Eijk,et al.  Inorganic scintillators in medical imaging. , 2002, Physics in medicine and biology.

[4]  Bongsoo Lee,et al.  Optical fiber-based gamma-ray spectroscopy with cerium-doped lutetium yttrium orthosilicate crystal , 2013 .

[5]  Joo Hyun Moon,et al.  Evaluation of the Detection Efficiency of LYSO Scintillator in the Fiber-Optic Radiation Sensor , 2014 .

[6]  C. Swinehart,et al.  Sodium Activated Cesium Iodide as a Gamma Ray and Charged Particle Detector , 1967 .

[7]  C. Melcher,et al.  Use of GSO for inelastic gamma-ray spectroscopy measurements in the borehole , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[8]  Chan Hee Park,et al.  Development of a scintillating fiber-optic sensor for the radioactive contamination measurement in a narrow area , 2011 .

[9]  Wook Jae Yoo,et al.  Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[10]  E. W. O'Dell,et al.  Calcium Fluoride as an X-Ray and Charged Particle Detector , 1966 .

[11]  Louis Archambault,et al.  Water-equivalent dosimeter array for small-field external beam radiotherapy. , 2007, Medical physics.

[12]  Wook Jae Yoo,et al.  Measurement of Cerenkov Radiation Induced by the Gamma-Rays of Co-60 Therapy Units Using Wavelength Shifting Fiber , 2014, Sensors.

[13]  Bongsoo Lee,et al.  Measurements of Relative Depth Doses Using Fiber-Optic Radiation Sensor and EBT Film for Brachytherapy Dosimetry , 2010, IEEE Transactions on Nuclear Science.

[14]  Louis Archambault,et al.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors. , 2010, Medical physics.

[15]  C. A. Baker,et al.  Reflective coverings for scintillation counters , 1970 .

[16]  M. R. Farukhi,et al.  Barium Fluoride as a Gamma Ray and Charged Particle Detector , 1971 .

[17]  H.W. Kraner,et al.  Radiation detection and measurement , 1981, Proceedings of the IEEE.

[18]  A. Beddar,et al.  Plastic scintillation dosimetry and its application to radiotherapy , 2006 .

[19]  K. Jang,et al.  Development and characterization of the integrated fiber-optic radiation sensor for the simultaneous detection of neutrons and gamma rays. , 2011, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[20]  E. Takada,et al.  A new optical fibre sensor for multipoint radiation measurement with sensing regions in its cladding , 2004 .

[21]  E. Takada,et al.  Application of General Purpose Fiber Optic Data Links to Radiation Measurements , 2003 .

[22]  G. Knoll Radiation Detection And Measurement, 3rd Ed , 2009 .