Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution.

The myocardial perfusion reserve, defined as the ratio of hyperemic and basal myocardial blood flow, is a useful indicator of the functional significance of a coronary artery lesion. Rapid magnetic resonance (MR) imaging for the noninvasive detection of a bolus-injected contrast agent as a MR tracer is applied to the measurement of regional tissue perfusion during rest and hyperemia, in patients with microvascular dysfunction. A Fermi function model for the distribution of tracer residence times in the myocardium is used to fit the MR signal curves. The myocardial perfusion reserve is calculated from the impulse response amplitudes for rest and hyperemia. The assumptions of the model are tested with Monte Carlo simulations, using a multiple path, axially distributed mathematical model of blood tissue exchange, which allows for systematic variation of blood flow, vascular volume, and capillary permeability. For a contrast-to-noise ratio of 6:1, and over a range of flows from 0.5 to 4.0 ml/min per g of tissue, the ratio of the impulse response amplitudes for hyperemic and basal flows is linearly proportional to the ratio of model blood flows, if the mean transit time of the input function is shorter than approximately 9 s. The uncertainty in the blood flow reserve estimates grows both at low (< 1.0 ml/min/g) and high (> 3-4 ml/min/g) flows. The predictions of the Monte Carlo simulations agree with the results of MR first pass studies in patients without significant coronary artery lesions and microvascular dysfunction, where the perfusion reserve in the territory of the left anterior descending coronary artery (LAD) correlates linearly with the intracoronary Doppler ultrasound flow reserve in the LAD (r = 0.84), in agreement with previous PET studies.

[1]  B R Rosen,et al.  Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchange , 1996, Magnetic resonance in medicine.

[2]  C. Higgins,et al.  Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging. , 1996, Radiology.

[3]  K Uğurbil,et al.  Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation , 1995, Magnetic resonance in medicine.

[4]  J Valk,et al.  Semiquantitation of regional myocardial blood flow in normal human subjects by first-pass magnetic resonance imaging. , 1995, American heart journal.

[5]  W. Hundley,et al.  Measurement of absolute epicardial coronary artery flow and flow reserve with breath-hold cine phase-contrast magnetic resonance imaging. , 1995, Circulation.

[6]  K. Yu,et al.  The Use of Contrast-Enhanced Magnetic Resonance Imaging To Define Ischemic Injury after Reperfusion: Comparison in Normal and Hypertrophied Hearts , 1994, Investigative radiology.

[7]  F. Prato,et al.  Measurement of the extraction efficiency and distribution volume for Gd‐DTPA in normal and diseased canine myocardium , 1993, Magnetic resonance in medicine.

[8]  K. Uğurbil,et al.  Contrast‐enhanced first pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemia , 1993, Magnetic resonance in medicine.

[9]  R. Wilson,et al.  Assessment of the human coronary circulation using a Doppler catheter. , 1991, The American journal of cardiology.

[10]  R. Wilson,et al.  Effects of adenosine on human coronary arterial circulation. , 1990, Circulation.

[11]  H. Weinmann,et al.  Tolerance of extracellular contrast agents for magnetic resonance imaging. , 1990, Investigative radiology.

[12]  R. Wilson,et al.  Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload. , 1990, Circulation.

[13]  R. Wilson,et al.  Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease. , 1987, Circulation.

[14]  C A Mistretta,et al.  Digital subtraction angiographic imaging of coronary flow reserve. , 1987, Circulation.

[15]  G L Wolf,et al.  Relaxation of water protons in the intra‐ and extracellular regions of blood containing Gd(DTPA) , 1986, Magnetic resonance in medicine.

[16]  William H. Press,et al.  Numerical recipes in C. The art of scientific computing , 1987 .

[17]  J B Bassingthwaighte,et al.  Stability of heterogeneity of myocardial blood flow in normal awake baboons. , 1985, Circulation research.

[18]  R. Wilson,et al.  Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man. , 1985, Circulation.

[19]  R. Slutsky,et al.  Tissue distribution and magnetic resonance spin lattice relaxation effects of gadolinium-DTPA. , 1985, Radiology.

[20]  L Axel,et al.  Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. , 1983, Investigative radiology.

[21]  K. Lipscomb,et al.  Effects of coronary stenoses on coronary flow reserve and resistance. , 1974, The American journal of cardiology.

[22]  C. Starmer,et al.  Indicator Transit Time Considered as a Gamma Variate , 1964, Circulation research.