Validation of finite element models for strain analysis of implant-supported prostheses using digital image correlation.

OBJECTIVES A validated numerical model for stress/strain predictions is essential in understanding the biomechanical behavior of implant-supported dental prostheses. The digital image correlation (DIC) method for full-field strain measurement was compared with finite element analysis (FEA) in assessing bone strain induced by implants. METHODS An epoxy resin model simulating the lower arch was made for the experimental test with acrylic resin replicas of the first premolar and second molar and threaded implants replacing the second premolar and first molar. Splinted (G1/G3) and non-splinted (G2/G4) metal-ceramic screw-retained crowns were fabricated and loaded with (G1/G2) or without (G3/G4) the second molar that provided proximal contact. A single-camera, two-dimensional DIC system was used to record deformation of the resin model surface under a load of 250N. Three-dimensional finite element (FE) models were constructed for the physical models using computer-aided design (CAD) software. Surface strains were used for comparison between the two methods, while internal strains at the implant/resin block interface were calculated using FEA. RESULTS Both methods found similar strain distributions over the simulant bone block surface, which indicated possible benefits of having splinted crowns and proximal contact in reducing bone strains. Internal strains predicted by FEA at the implant-resin interface were 8 times higher than those on the surface of the model, and they confirmed the results deduced from the surface strains. FEA gave higher strain values than experiments, probably due to incorrect material properties being used. SIGNIFICANCE DIC is a useful tool for validating FE models used for the biomechanical analysis of dental prosthesis.

[1]  E. Radin,et al.  Bone remodeling in response to in vivo fatigue microdamage. , 1985, Journal of biomechanics.

[2]  J H Keyak,et al.  Validation of an automated method of three-dimensional finite element modelling of bone. , 1993, Journal of biomedical engineering.

[3]  R. Jagger,et al.  The effect of cross-linking chain length on mechanical properties of a dough-molded poly(methylmethacrylate) resin. , 1992, Dental materials : official publication of the Academy of Dental Materials.

[4]  H. Iplikçioğlu,et al.  Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a Morse taper implant. , 2003, The International journal of oral & maxillofacial implants.

[5]  Matthias Karl,et al.  Biomechanical methods applied in dentistry: a comparative overview of photoelastic examinations, strain gauge measurements, finite element analysis and three-dimensional deformation analysis. , 2009, The European journal of prosthodontics and restorative dentistry.

[6]  R. James,et al.  The experimental verification of the efficacy of finite element modeling to dental implant systems. , 1996, The Journal of oral implantology.

[7]  Aslihan Usumez,et al.  The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study. , 2004, The Journal of prosthetic dentistry.

[8]  T. Taylor,et al.  Strain Situation after Fixation of Three-Unit Ceramic Veneered Implant Superstructures , 2005, Implant dentistry.

[9]  R Skalak,et al.  Biomechanical considerations in osseointegrated prostheses. , 1983, The Journal of prosthetic dentistry.

[10]  Jui-Ting Hsu,et al.  Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis. , 2005, Clinical oral implants research.

[11]  Jeremy D Seidt,et al.  Comparison of strains for splinted and nonsplinted implant prostheses using three-dimensional image correlation. , 2010, The International journal of oral & maxillofacial implants.

[12]  Angelo A Caputo,et al.  Effect of splinting and interproximal contact tightness on load transfer by implant restorations. , 2002, The Journal of prosthetic dentistry.

[13]  F van Keulen,et al.  Development and experimental validation of a three-dimensional finite element model of the human scapula , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[14]  Daniel P Nicolella,et al.  Measurement of microstructural strain in cortical bone. , 2005, European journal of morphology.

[15]  Xi Ding,et al.  Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis. , 2009, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[16]  Alexei Mossolov,et al.  Tooth-implant connection: some biomechanical aspects based on finite element analyses. , 2002, Clinical oral implants research.

[17]  C. Soares,et al.  Influence of root embedment material and periodontal ligament simulation on fracture resistance tests. , 2005, Brazilian oral research.

[18]  H Weber,et al.  Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae. , 1995, The International journal of oral & maxillofacial implants.

[19]  R. Aversa,et al.  Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite elements analysis. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[20]  P Rüegsegger,et al.  Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions. , 1999, Journal of biomechanics.

[21]  Uwe Wolfram,et al.  Periodontal ligament hydrostatic pressure with areas of root resorption after application of a continuous torque moment. , 2007, The Angle orthodontist.

[22]  David C Watts,et al.  Measurement of the full-field polymerization shrinkage and depth of cure of dental composites using digital image correlation. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[23]  H. Iplikçioğlu,et al.  A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants. , 2002, The International journal of prosthodontics.

[24]  J M Leary,et al.  Influence of post dimension on stress distribution in dentin. , 1996, The Journal of prosthetic dentistry.

[25]  B. Noble,et al.  Bone microdamage and cell apoptosis. , 2003, European cells & materials.

[26]  M. Pamenius,et al.  The determination of elastic constants by dynamic experiments. , 1986, Dental materials : official publication of the Academy of Dental Materials.

[27]  S. Bernardes,et al.  Photoelastic analysis of stress patterns from different implant-abutment interfaces. , 2009, The International journal of oral & maxillofacial implants.

[28]  Lianshan Lin,et al.  Digital image correlation analysis of the load transfer by implant-supported restorations. , 2011, Journal of biomechanics.

[29]  Jen-Chyan Wang,et al.  Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. , 2008, The International Journal of Oral and Maxillofacial Implants.

[30]  K. Akca,et al.  A photoelastic and strain-gauge analysis of interface force transmission of internal-cone implants. , 2008, The International journal of periodontics & restorative dentistry.

[31]  T. Taylor,et al.  In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations. , 2007, The Journal of prosthetic dentistry.

[32]  K. Akca,et al.  Effect of compromised cortical bone on implant load distribution. , 2008, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[33]  K. Akca,et al.  Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants. , 2009, The International journal of oral & maxillofacial implants.

[34]  Jonathan Reeve,et al.  Osteocyte function, osteocyte death and bone fracture resistance , 2000, Molecular and Cellular Endocrinology.

[35]  C. Whyne,et al.  Toward Characterization of Craniofacial Biomechanics , 2010, The Journal of craniofacial surgery.

[36]  T. Taylor,et al.  Static implant loading caused by as-cast metal and ceramic-veneered superstructures. , 2005, The Journal of prosthetic dentistry.