Reproducibility and validity of electric source localisation with high-resolution electroencephalography.

The present study investigates the reproducibility and validity of the EEG source localisation of somatosensory evoked potentials (SEPs) using high-resolution EEG (61 scalp electrodes) and a source reconstruction on the basis of the individual brain morphology as obtained from magnetic resonance images (MRIs). The somatosensory evoked potentials (SEPs) to electrical stimulation of the right median nerve were repeatedly collected from the scalp of one healthy subject in 9 replications run on 9 different days. The source reconstruction for the 19 ms SEP component was performed by using a single moving dipole model as a source model. Two different head models were used: a spherical 3 shell model and a more realistically shaped 3 compartment model computed using the boundary element method (BEM). The source locations of the 19 ms SEP component were found to be highly reproducible using both head models: the mean standard deviation of the dipole locations was found to be 2.6 mm for the 3 shell model and 4 mm for the more realistically shaped head model. By projection into the individual MRI, the dipoles resulting from either head models were found to be located within the postcentral gyrus. The electric source locations were consistent with the maximum of the task-specific changes seen in a functional magnetic resonance imaging (fMRI) experiment when using the same somatosensory stimulation protocol.

[1]  T. Elbert,et al.  Oscillatory Event-Related Brain Dynamics , 1994, NATO ASI Series.

[2]  Olaf Dössel,et al.  Possibilities of Functional Brain Imaging Using a Combination of MEG and MRT , 1994 .

[3]  H. Steinmetz,et al.  Craniocerebral topography within the international 10-20 system. , 1989, Electroencephalography and clinical neurophysiology.

[4]  R. C. Oldfield THE ASSESSMENT AND ANALYSIS OF HANDEDNESS , 1971 .

[5]  R. Hari,et al.  Neuromagnetic studies of somatosensory system: Principles and examples , 1985, Progress in Neurobiology.

[6]  M Scherg,et al.  Preoperative localization of the central sulcus by dipole source analysis of early somatosensory evoked potentials and three-dimensional magnetic resonance imaging. , 1994, Journal of neurosurgery.

[7]  Christo Pantev,et al.  Reproducibility and Validity of Neuromagnetic Source Localization Using A Large Array Biomagnetometer , 1991 .

[8]  Onno W. Weier,et al.  On the numerical accuracy of the boundary element method (EEG application) , 1989, IEEE Transactions on Biomedical Engineering.

[9]  Franca Tecchio,et al.  Neuromagnetic fields of the brain evoked by voluntary movement and electrical stimulation of the index finger , 1995, Brain Research.

[10]  C C Wood,et al.  Electrical sources in human somatosensory cortex: identification by combined magnetic and potential recordings. , 1985, Science.

[11]  Stephen J. Jones,et al.  Potentials evoked in human and monkey cerebral cortex by stimulation of the median nerve. A review of scalp and intracranial recordings. , 1991, Brain : a journal of neurology.

[12]  B Lütkenhöner,et al.  A Neuromagnetic Study of the Functional Organization of the Sensorimotor Cortex , 1994, The European journal of neuroscience.

[13]  R. Llinás,et al.  The interactive use of magnetoencephalography in stereotactic image-guided neurosurgery. , 1996, Neurosurgery.

[14]  P. M. Rossini,et al.  Neuromagnetic somatosensory homunculus: A non-invasive approach in humans , 1991, Neuroscience Letters.

[15]  P. Rossini,et al.  Short latency somatosensory evoked responses to median nerve stimulation in healthy humans: electric and magnetic recordings. , 1989, The International journal of neuroscience.