Secondary (low-side) surges in distribution transformers

The Task Force was formed in response to a proposal that a secondary, or low-side, current surge withstand design test be included in the IEEE test standards. It was charged with reviewing all information on low-side surges and determining if revisions of dielectric tests of distribution transformers are indeed warranted. Although agreement on a standard test has not been reached, substantial work has been done and is summarized. The problem of failures of distribution transformers due to low-side surge phenomena is described, and how it is being addressed by the industry is detailed. The problem is described in historical perspective along with the varied viewpoints of the Task Force members. The system and transformer parameters that influence the problem are discussed. Proposed solutions and their tradeoffs are presented. A reference list of published literature is provided.<<ETX>>

[1]  D. J. Ward Evaluating product reliability costs , 1990 .

[2]  C. J. McMillen,et al.  Gas Bubble Studies and Impulse Tests on Distribution Transformers During Loading Above Nameplate Rating , 1983, IEEE Power Engineering Review.

[3]  R. C. Dugan,et al.  Low-voltage-side current-surge phenomena in single-phase distribution transformer systems , 1988 .

[4]  W. A. McMorris,et al.  Voltage Stresses in Distribution Transformers Due to Lightning Currents in Low-Voltage Circuits , 1948, Transactions of the American Institute of Electrical Engineers.

[5]  D. D. MacCarthy,et al.  Lightning Investigation on a Rural Distribution System , 1949, Transactions of the American Institute of Electrical Engineers.

[6]  D. W. Caverly,et al.  Scaled low-voltage side surge current tests on a model distribution system , 1988 .

[7]  D. R. Smith,et al.  A Simplified Lumped Parameter Model for Finding Distribution Transformer and Secondary System Responses to Lightning , 1989, IEEE Power Engineering Review.

[8]  D. J. Kvaltine,et al.  Lightning Faults on Distribution Lines , 1989, IEEE Power Engineering Review.

[9]  G.H. Kaufmann Impulse testing of distribution transformers under load , 1977, IEEE Transactions on Power Apparatus and Systems.

[10]  D. E. Parrish,et al.  Lightning-caused distribution transformer outages on a Florida distribution system , 1991 .

[11]  A. J. Eriksson The Incidence of Lightning Strikes to Power Lines , 1987, IEEE Transactions on Power Delivery.

[12]  F.D. Martzloff Coordination of Surge Protectors in Low-Voltage AC Power Circuits , 1980, IEEE Transactions on Power Apparatus and Systems.

[13]  T. J. Dionise,et al.  Lightning induced failures in distributed transformers , 1988 .

[14]  R. C. Dugan,et al.  Protecting distribution transformers from low-side current surges , 1990 .

[15]  M. Darveniza,et al.  Lightning Protection of Pole Mounted Transformers , 1989, IEEE Power Engineering Review.

[16]  F.D. Martzloff The Propagation and Attenuation of Surge Voltages and Surge Currents in Low-VOltage AC Circuits , 1983, IEEE Transactions on Power Apparatus and Systems.