High field human imaging

This review article examines the state of knowledge regarding human imaging using MRI at high main magnetic field strengths. The article starts with a summary of the technical issues associated with magnetic field strengths in the range of 3–8 T, including magnet characteristics and the properties of radiofrequency magnetic fields, with special reference to sensitivity, power deposition, and homogeneity. The published data on tissue‐water relaxation times in the brain is tabulated and the implications for contrast and pulse sequence implementation is elucidated. The behavior of the major fast imaging sequences, fast low angle shot (FLASH), rapid acquisition with relaxation enhancement (RARE), and echo planar imaging (EPI), is examined in this context. A number of anatomical images from 3 T systems are presented as examples. Particular attention is given to various forms of vascular imaging, namely, time of flight angiography, venography, and arterial spin labeling. The most complex changes in contrast with main magnetic field strength are in activation studies utilizing the blood oxygen level dependent mechanism, which are examined in detail. Improvements in spatial specificity are emphasized, particularly in conjunction with spin‐echo imaging. The article concludes with a discussion of the current status and the potential impact of technical developments such as parallel imaging. J. Magn. Reson. Imaging 2003;18:519–529. © 2003 Wiley‐Liss, Inc.

[1]  Michael B. Smith,et al.  Calculations of B1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically‐accurate human body model , 2001, Magnetic resonance in medicine.

[2]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[3]  J R Reichenbach,et al.  High-Resolution MR Venography at 3.0 Tesla , 2000, Journal of computer assisted tomography.

[4]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[5]  J B Poline,et al.  Transient decrease in water diffusion observed in human occipital cortex during visual stimulation , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[6]  D. Alsop,et al.  The sensitivity of low flip angle RARE imaging , 1997, Magnetic resonance in medicine.

[7]  G. Glover,et al.  Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[8]  J. Haxby,et al.  Localization of Cardiac-Induced Signal Change in fMRI , 1999, NeuroImage.

[9]  Jean A. Tkach,et al.  2D and 3D high resolution gradient echo functional imaging of the brain: Venous contributions to signal in motor cortex studies , 1994, NMR in biomedicine.

[10]  Toralf Mildner,et al.  An Investigation of the Value of Spin-Echo-Based fMRI Using a Stroop Color–Word Matching Task and EPI at 3 T , 2002, NeuroImage.

[11]  Bharat B. Biswal,et al.  SPONTANEOUS FLUCTUATIONS IN CEREBRAL OXYGEN SUPPLY , 1998 .

[12]  Peter Andersen,et al.  Proton T2 relaxation study of water, N‐acetylaspartate, and creatine in human brain using Hahn and Carr‐Purcell spin echoes at 4T and 7T , 2002, Magnetic resonance in medicine.

[13]  Carlo Pierpaoli,et al.  Simultaneous Measurement of ΔR2 and ΔR2* in Cat Brain during Hypoxia and Hypercapnia , 1997, NeuroImage.

[14]  K. Uğurbil,et al.  Analysis of wave behavior in lossy dielectric samples at high field , 2002, Magnetic resonance in medicine.

[15]  A. Kangarlu,et al.  Human magnetic resonance imaging at 8 T , 1998, NMR in biomedicine.

[16]  Petra Schmalbrock,et al.  Visualization of microvascularity in glioblastoma multiforme with 8-T high-spatial-resolution MR imaging. , 2002, AJNR. American journal of neuroradiology.

[17]  R. S. Hinks,et al.  Stabilization of echo amplitudes in FSE sequences , 1993, Magnetic resonance in medicine.

[18]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[19]  P. Röschmann,et al.  Spectroscopy and imaging with a 4 tesla whole‐body mr system , 1988, NMR in biomedicine.

[20]  S. Ogawa Brain magnetic resonance imaging with contrast-dependent oxygenation , 1990 .

[21]  B R Rosen,et al.  Mr contrast due to intravascular magnetic susceptibility perturbations , 1995, Magnetic resonance in medicine.

[22]  V. Haughton,et al.  T1 and T2 measurements on a 1.5-T commercial MR imager. , 1989, Radiology.

[23]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[24]  J. Saunders,et al.  k‐space detection and correction of physiological artifacts in fMRI , 1997, Magnetic resonance in medicine.

[25]  A. Shmuel,et al.  Imaging brain function in humans at 7 Tesla , 2001, Magnetic resonance in medicine.

[26]  A. Anderson,et al.  Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes. , 2001, Physics in medicine and biology.

[27]  M. Schnall,et al.  Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla , 2002, Magnetic resonance in medicine.

[28]  R. Goebel,et al.  7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.

[29]  D G Norris,et al.  Reduced power multislice MDEFT imaging , 2000, Journal of magnetic resonance imaging : JMRI.

[30]  J. Reichenbach,et al.  Quantitative differentiation between BOLD models in fMRI , 2001, Magnetic resonance in medicine.

[31]  P T Fox,et al.  Detection of the brain response during a cognitive task using perfusion‐based event‐related functional MRI , 2000, Neuroreport.

[32]  A. Grinvald,et al.  Interactions Between Electrical Activity and Cortical Microcirculation Revealed by Imaging Spectroscopy: Implications for Functional Brain Mapping , 1996, Science.

[33]  P A Rinck,et al.  Nuclear relaxation of human brain gray and white matter: Analysis of field dependence and implications for MRI , 1990, Magnetic resonance in medicine.

[34]  J W Carlson,et al.  Electromagnetic fields of surface coil in vivo NMR at high frequencies , 1991, Magnetic resonance in medicine.

[35]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[36]  J Hennig,et al.  Detection of BOLD changes by means of a frequency‐sensitive trueFISP technique: preliminary results , 2001, NMR in biomedicine.

[37]  Ewald Moser,et al.  On the origin of respiratory artifacts in BOLD-EPI of the human brain. , 2002, Magnetic resonance imaging.

[38]  R S Balaban,et al.  MR relaxation times in human brain: measurement at 4 T. , 1996, Radiology.

[39]  P. Lauterbur,et al.  The sensitivity of the zeugmatographic experiment involving human samples , 1979 .

[40]  T. Ibrahim,et al.  Dielectric resonance phenomena in ultra high field MRI. , 1999, Journal of computer assisted tomography.

[41]  Seong-Gi Kim,et al.  Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 T , 2002, Magnetic resonance in medicine.

[42]  P A Bottomley,et al.  RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. , 1978, Physics in medicine and biology.

[43]  K. Uğurbil,et al.  Different excitation and reception distributions with a single‐loop transmit‐receive surface coil near a head‐sized spherical phantom at 300 MHz , 2002, Magnetic resonance in medicine.

[44]  P. Mitra,et al.  The nature of spatiotemporal changes in cerebral hemodynamics as manifested in functional magnetic resonance imaging , 1997, Magnetic resonance in medicine.

[45]  R. Buxton,et al.  Estimation of respiration‐induced noise fluctuations from undersampled multislice fMRI data † , 2001, Magnetic resonance in medicine.

[46]  S. H. Koenig,et al.  Determinants of Proton Relaxation Rates in Tissue , 1984, Magnetic resonance in medicine.

[47]  J. Bodurka,et al.  Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes , 2002 .

[48]  G. Glover,et al.  Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imaging , 2002, Magnetic resonance in medicine.

[49]  R. Kauppinen,et al.  Venous blood effects in spin‐echo fMRI of human brain , 1999, Magnetic resonance in medicine.

[50]  J. Gore,et al.  Intravascular susceptibility contrast mechanisms in tissues , 1994, Magnetic resonance in medicine.

[51]  A. Shmuel,et al.  Investigation of the initial dip in fMRI at 7 Tesla , 2001, NMR in biomedicine.

[52]  W. Edelstein,et al.  The intrinsic signal‐to‐noise ratio in NMR imaging , 1986, Magnetic resonance in medicine.

[53]  Anna C. Nobre,et al.  Cortical Activation in the Human Brain during Lateral Saccades Using EPISTAR Functional Magnetic Resonance Imaging , 1996, NeuroImage.

[54]  Yong Man Ro,et al.  NMR Venography Using the Susceptibility Effect Produced by Deoxyhemoglobin , 1992, Magnetic resonance in medicine.

[55]  P. Robitaille Black body and transverse electromagnetic resonators operating at 340 MHz: volume RF coils for ultra high field MRI. , 1999, Journal of computer assisted tomography.

[56]  J. R. Baker,et al.  The intravascular contribution to fmri signal change: monte carlo modeling and diffusion‐weighted studies in vivo , 1995, Magnetic resonance in medicine.

[57]  J. Gore,et al.  Relative contributions of chemical exchange and other relaxation mechanisms in protein solutions and tissues , 1989, Magnetic resonance in medicine.

[58]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[59]  H C Charles,et al.  Reproducibility of relaxation and spin‐density parameters in phantoms and the human brain measured by MR imaging at 1.5T , 1986, Magnetic resonance in medicine.

[60]  K. Uğurbil,et al.  High‐resolution, spin‐echo BOLD, and CBF fMRI at 4 and 7 T , 2002, Magnetic resonance in medicine.

[61]  K. Uğurbil,et al.  Polarization of the RF field in a human head at high field: A study with a quadrature surface coil at 7.0 T , 2002, Magnetic resonance in medicine.

[62]  S G Kim,et al.  Perfusion imaging by a flow‐sensitive alternating inversion recovery (Fair) technique: Application to functional brain imaging , 1997, Magnetic resonance in medicine.

[63]  Jianfeng Gao,et al.  Perfusion‐based event‐related functional MRI , 1999, Magnetic resonance in medicine.

[64]  Risto A. Kauppinen,et al.  Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging , 1998, Nature Medicine.

[65]  D P Auer,et al.  Signal undershoots following visual stimulation: A comparison of gradient and spin‐echo BOLD sequences , 1998, Magnetic resonance in medicine.

[66]  P. Robitaille,et al.  Macroscopic susceptibility in ultra high field MRI. , 1999, Journal of computer assisted tomography.

[67]  R Turner,et al.  Simultaneous measurement of DeltaR2 and DeltaR2* in cat brain during hypoxia and hypercapnia. , 1997, NeuroImage.

[68]  Risto A. Kauppinen,et al.  Determination of Oxygen Extraction Ratios by Magnetic Resonance Imaging , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[69]  E. DeYoe,et al.  Reduction of physiological fluctuations in fMRI using digital filters , 1996, Magnetic resonance in medicine.

[70]  B B Biswal,et al.  Spontaneous fluctuations in cerebral oxygen supply. An introduction. , 1998, Advances in experimental medicine and biology.

[71]  A. Kangarlu,et al.  High resolution MRI of the deep brain vascular anatomy at 8 Tesla: susceptibility-based enhancement of the venous structures. , 1999, Journal of computer assisted tomography.

[72]  A. Shmuel,et al.  Perfusion‐based high‐resolution functional imaging in the human brain at 7 Tesla , 2002, Magnetic resonance in medicine.

[73]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[74]  Three second clinical NMR images using a gradient recalled acquisition in a study state mode (GRASS) , 1986 .

[75]  D. Roberts,et al.  Magnetization transfer imaging of the brain: A quantitative comparison of results obtained at 1.5 and 4.0 t , 1999, Journal of magnetic resonance imaging : JMRI.

[76]  Michael B. Smith,et al.  Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coil , 2001, Magnetic resonance in medicine.

[77]  C N Chen,et al.  The field dependence of NMR imaging. II. Arguments concerning an optimal field strength , 1986, Magnetic resonance in medicine.

[78]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[79]  M. Gyngell,et al.  The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences. , 1988, Magnetic resonance imaging.

[80]  E Yacoub,et al.  Detection of the early negative response in fMRI at 1.5 Tesla , 1999, Magnetic resonance in medicine.

[81]  J. Hennig,et al.  Detection of brain activation using oxygenation sensitive functional spectroscopy , 1994, Magnetic resonance in medicine.

[82]  Alan H Wilman,et al.  Application of magnetization transfer at 3.0 T in three‐dimensional time‐of‐flight magnetic resonance angiography of the intracranial arteries , 2002, Journal of magnetic resonance imaging : JMRI.

[83]  D. Hoult Sensitivity and Power Deposition in a High‐Field Imaging Experiment , 2000, Journal of magnetic resonance imaging : JMRI.

[84]  P. Bandettini,et al.  Echo-planar imaging : theory, technique and application , 1998 .

[85]  Ravi S. Menon,et al.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. , 1993, Biophysical journal.

[86]  S G Kim,et al.  Accurate T1 determination from inversion recovery images: Application to human brain at 4 Tesla , 1994, Magnetic resonance in medicine.

[87]  J Vetter,et al.  Whole-body MR imaging and spectroscopy with a 4-T system. , 1988, Radiology.

[88]  J. Voyvodic,et al.  High‐resolution echo‐planar fMRI of human visual cortex at 3.0 tesla , 1997, NMR in biomedicine.

[89]  B. Rosen,et al.  Microscopic susceptibility variation and transverse relaxation: Theory and experiment , 1994, Magnetic resonance in medicine.

[90]  X Hu,et al.  Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data , 1996, Magnetic resonance in medicine.

[91]  D. Feinberg,et al.  GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique , 1991, Magnetic resonance in medicine.

[92]  N Fujita,et al.  Extravascular contribution of blood oxygenation level‐dependent signal changes: A numerical analysis based on a vascular network model , 2001, Magnetic resonance in medicine.

[93]  E. Moser,et al.  Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI. , 1997, Cellular and molecular biology.

[94]  S. Holland,et al.  NMR relaxation times in the human brain at 3.0 tesla , 1999, Journal of magnetic resonance imaging : JMRI.

[95]  B. Biswal,et al.  Functional connectivity in the motor cortex of resting human brain using echo‐planar mri , 1995, Magnetic resonance in medicine.

[96]  Thomas T. Liu,et al.  Analysis and Design of Perfusion-Based Event-Related fMRI Experiments , 2002, NeuroImage.

[97]  A Jesmanowicz,et al.  Artifacts in functional magnetic resonance imaging from gaseous oxygen , 1995, Journal of magnetic resonance imaging : JMRI.

[98]  Ravi S. Menon,et al.  Imaging at high magnetic fields: initial experiences at 4 T. , 1993, Magnetic resonance quarterly.