Technical note Best connection scheme of collector modules of thermosyphon solar water heater operated at high temperatures

Large scale thermosyphon solar water heater for high temperature applications is simulated by the use of the Transient Simulation Program (TRNSYS). A daily hot water load of 1500 l/day and 2500 l/day at 80°C was assumed. The hot water is consumed daily from 08·00–17·00 h. A back-up electric auxiliary heater was added to the system in two schemes: first, located inside the storage tank with a thermostat; second, outside the tank connected to the heating system between the tank and the facilities. The collector modules were connected in five different schemes: first, all collectors were connected in series in one line, or collectors were connected in two, three, four or five parallel lines each consisting of many collectors. The results showed that the best connection is when the 20 collectors, comprising the system, are connected in two parallel lines each consisting of 10 collectors. It was found that the monthly and yearly useful energy from the system was higher when the auxiliary water heater was added to the system outside the storage tank.

[1]  H. P. Garg,et al.  System design in solar water heaters with natural circulation , 1968 .

[2]  M. F. Young,et al.  Performance Characteristics of a Thermosyphon Solar Domestic Hot Water System , 1981 .

[3]  K. S. Ong A finite-difference method to evaluate the thermal performance of a solar water heater , 1974 .

[4]  R. Greif,et al.  DETAILED LOOP MODEL (DLM) ANALYSIS OF LIQUID SOLAR THERMOSIPHONS WITH HEAT EXCHANGERS , 1981 .

[5]  Brian Norton,et al.  Verified accurate performance simulation model of direct thermosyphon solar energy water heaters , 1988 .

[6]  James E. Braun,et al.  System modeling and operation characteristics of thermosyphon solar water heaters , 1985 .

[7]  P. V. Pedersen System design optimization for large building integrated solar heating systems for domestic hot water , 1993 .

[8]  Graham L. Morrison,et al.  Simulation of the long term performance of thermosyphon solar water heaters , 1984 .

[9]  G. Löf,et al.  The optimization of tank-volume-to-collector-area ratio for a thermosyphon solar water heater , 1996 .

[10]  D. J. Close,et al.  The performance of solar water heaters with natural circulation , 1962 .

[11]  G. N. Tiwari,et al.  Large scale solar water heater: Experimental and theoretical studies , 1991 .

[12]  W. H. Bloss,et al.  Advances in solar energy technology : proceedings of the Biennial Congress of the International Solar Energy Society, Hamburg, Federal Republic of Germany, 13-18 September 1987 , 1988 .