Acoustic mechanisms that determine the ear-canal sound pressures generated by earphones.

In clinical measurements of hearing sensitivity, a given earphone is assumed to produce essentially the same sound-pressure level in all ears. However, recent measurements [Voss et al., Ear and Hearing (in press)] show that with some middle-ear pathologies, ear-canal sound pressures can deviate by as much as 35 dB from the normal-ear value; the deviations depend on the earphone, the middle-ear pathology, and frequency. These pressure variations cause errors in the results of hearing tests. Models developed here identify acoustic mechanisms that cause pressure variations in certain pathological conditions. The models combine measurement-based Thévenin equivalents for insert and supra-aural earphones with lumped-element models for both the normal ear and ears with pathologies that alter the ear's impedance (mastoid bowl, tympanostomy tube, tympanic-membrane perforation, and a "high-impedance" ear). Comparison of the earphones' Thévenin impedances to the ear's input impedance with these middle-ear conditions shows that neither class of earphone acts as an ideal pressure source; with some middle-ear pathologies, the ear's input impedance deviates substantially from normal and thereby causes abnormal ear-canal pressure levels. In general, for the three conditions that make the ear's impedance magnitude lower than normal, the model predicts a reduced ear-canal pressure (as much as 35 dB), with a greater pressure reduction with an insert earphone than with a supra-aural earphone. In contrast, the model predicts that ear-canal pressure levels increase only a few dB when the ear has an increased impedance magnitude; the compliance of the air-space between the tympanic membrane and the earphone determines an upper limit on the effect of the middle-ear's impedance increase. Acoustic leaks at the earphone-to-ear connection can also cause uncontrolled pressure variations during hearing tests. From measurements at the supra-aural earphone-to-ear connection, we conclude that it is unusual for the connection between the earphone cushion and the pinna to seal effectively for frequencies below 250 Hz. The models developed here explain the measured pressure variations with several pathologic ears. Understanding these mechanisms should inform the design of more accurate audiometric systems which might include a microphone that monitors the ear-canal pressure and corrects deviations from normal.

[1]  E. Cantekin,et al.  Tympanometric Pattern Classification in Relation to Middle Ear Effusions , 1975, The Annals of otology, rhinology, and laryngology.

[2]  S. E. Voss,et al.  Measurement of acoustic impedance and reflectance in the human ear canal. , 1994, The Journal of the Acoustical Society of America.

[3]  Harris Jd,et al.  Proem to a quantum leap in audiometric data collection and management. , 1978 .

[4]  D. Bagger-sjöbäck,et al.  Shape and displacement patterns of the gerbil tympanic membrane in experimental otitis media with effusion , 1995, Hearing Research.

[5]  E. Corliss,et al.  The Response of Earphones in Ears and Couplers , 1954 .

[6]  M. Kringlebotn,et al.  Network model for the human middle ear. , 1988, Scandinavian audiology.

[7]  M. Kringlebotn,et al.  The size of the middle ear and the mastoid air cell. , 1978, Acta oto-laryngologica.

[8]  J J Rosowski,et al.  Measurements of the acoustic input impedance of cat ears: 10 Hz to 20 kHz. , 1994, The Journal of the Acoustical Society of America.

[9]  D. Lim,et al.  Human tympanic membrane. An ultrastructural observation. , 1970, Acta oto-laryngologica.

[10]  E. Shaw,et al.  Earcanal pressure generated by circumaural and supraaural earphones. , 1966, The Journal of the Acoustical Society of America.

[11]  David P. Egolf Mathematical modeling of a probe-tube microphone , 1977 .

[12]  J. Harris Proem to a quantum leap in audiometric data collection and management. , 1978, The Journal of auditory research.

[13]  John J. Rosowski,et al.  Cadaver Middle Ears as Models for Living Ears: Comparisons of Middle Ear Input Immittance , 1990, The Annals of otology, rhinology, and laryngology.

[14]  S. E. Voss,et al.  Middle Ear Pathology Can Affect the Ear‐Canal Sound Pressure Generated by Audiologic Earphones , 2000, Ear and hearing.

[15]  S B Luks,et al.  Clinical applicability of insert earphones for audiometry. , 1989, Audiology : official organ of the International Society of Audiology.

[16]  E. Shaw The External Ear , 1974 .

[17]  D H Keefe,et al.  Ear-canal impedance and reflection coefficient in human infants and adults. , 1993, The Journal of the Acoustical Society of America.

[18]  Jozef J. Zwislocki,et al.  Analysis of the Middle‐Ear Function. Part I: Input Impedance , 1962 .

[19]  Gerald A. Studebaker,et al.  Earphones in audiometry , 1988 .

[20]  M C Killion,et al.  Comments on "Earphones in Audiometry" [Zwislocki et al., J. Acoust. Soc. Am. 83, 1688-1689 (1988)]. , 1989, The Journal of the Acoustical Society of America.

[21]  M P Gorga,et al.  Comparison between intensity and pressure as measures of sound level in the ear canal. , 1998, The Journal of the Acoustical Society of America.

[22]  V. Rich Personal communication , 1989, Nature.

[23]  S. Hamburger,et al.  The prevalence of tympanostomy tubes in children in the United States, 1988. , 1993, American journal of public health.

[24]  Jont B. Allen,et al.  Measurement of Eardrum Acoustic Impedance , 1986 .

[25]  W M Rabinowitz,et al.  Measurement of the acoustic input immittance of the human ear. , 1981, The Journal of the Acoustical Society of America.